Extraction algorithm of pulmonary fissures from thin-section CT images based on linear feature detector method
暂无分享,去创建一个
Noboru Niki | Mitsuru Kubo | Kenji Eguchi | Noriyuki Moriyama | S. Nakagawa | R. Kakinuma | Masahiro Kaneko | N. Niki | R. Kakinuma | K. Eguchi | M. Kaneko | N. Moriyama | H. Omatsu | H. Omatsu | N. Yamaguchi | N. Yamaguchi | M. Kubo | S. Nakagawa
[1] B. Raasch,et al. Radiographic anatomy of the interlobar fissures: a study of 100 specimens. , 1982, AJR. American journal of roentgenology.
[2] W. Kalender,et al. Evaluation of section sensitivity profiles and image noise in spiral CT. , 1992, Radiology.
[3] H Anno,et al. Minimum scan speeds for suppression of motion artifacts in CT. , 1992, Radiology.
[4] Y. Kawata,et al. Computer-aided diagnosis for pulmonary nodules based on helical CT images , 1998, Proceedings. Fourteenth International Conference on Pattern Recognition (Cat. No.98EX170).
[5] Noboru Niki,et al. Bias field correction of chest thin section CT images , 1997, Proceedings of International Conference on Image Processing.
[6] Y H Auh,et al. Anatomy of the minor fissure: evaluation with thin-section CT. , 1989, Radiology.
[7] C. J. Ritchie,et al. Predictive respiratory gating: a new method to reduce motion artifacts on CT scans. , 1994, Radiology.
[8] K. Mori,et al. Small nodular lesions in the lung periphery: new approach to diagnosis with CT. , 1990, Radiology.
[9] R. Brooks,et al. Beam hardening in X-ray reconstructive tomography , 1976 .
[10] Noboru Niki,et al. Three-dimensional analysis of lung areas using thin slice CT images , 1996, Medical Imaging.
[11] H. Ohmatsu,et al. Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. , 1996, Radiology.
[12] M. Laval-jeantet,et al. Computed Tomography of the Pulmonary Fissures: Normal Anatomy , 1982, Journal of computer assisted tomography.
[13] Michael F. McNitt-Gray,et al. Pattern classification approach to characterizing solitary pulmonary nodules imaged on high-resolution computed tomography , 1996, Medical Imaging.
[14] R M Steiner,et al. The right mid-lung window. , 1982, Radiology.
[15] G. Vanderbrug. Experiments in iterative enhancement of linear features , 1977 .
[16] A. Proto,et al. Computed tomography of the major and minor fissures. , 1983, AJR. American journal of roentgenology.
[17] P. Joseph,et al. A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners , 1978, Journal of computer assisted tomography.
[18] Xinhua Zhuang,et al. Image Analysis Using Mathematical Morphology , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.
[19] Tomotaka Sobue,et al. A case‐control study for evaluating lung‐cancer screening in Japan , 1992, International journal of cancer.
[20] A. Macovski,et al. Nonlinear Polychromatic and Noise Artifacts in X‐Ray Computed Tomography Images , 1979, Journal of computer assisted tomography.
[21] A. Proto,et al. Pulmonary nodules studied by computed tomography. , 1985, Radiology.
[22] R M Henkelman,et al. The double-fissure sign: a motion artifact on thin-section CT scans. , 1987, Radiology.
[23] E A Zerhouni,et al. CT of the solitary pulmonary nodule. , 1980, AJR. American journal of roentgenology.
[24] R. Alfidi,et al. The effects of biological motion on CT resolution. , 1976, AJR. American journal of roentgenology.
[25] Ralph Bernstein,et al. Digital Image Processing of Earth Observation Sensor Data , 1976, IBM J. Res. Dev..
[26] A L Baert,et al. Initial experience with volume CT scanning. , 1990, Journal of computer assisted tomography.
[27] Medlar Em,et al. Variations in interlobar fissures. , 1947 .