Discrete cortical responses from multi-site supra-choroidal electrical stimulation in the feline retina

Exploration into electrical stimulation of the retina has thus far focussed primarily upon the development of prostheses targeted at one of two sites of intervention - the epi- and sub-retinal surfaces. These two approaches have sound, logical merit owing to their proximity to retinal neurons and their potential to deliver stimuli via the surviving retinal neural networks respectively. There is increasing evidence, however, that electric field effects, electrode engineering limitations, and electrode-tissue interactions limit the spatial resolution that once was hoped could be elicited from electrical stimulation at epi- and sub-retinal sites. An alternative approach has been proposed that places a stimulating electrode array within the supra-choroidal space - that is, between the sclera and the choroid. Here we investigate whether discrete, cortical activity patterns can be elicited via electrical stimulation of a feline retina using a custom, 14 channel, silicone rubber and Pt electrode array arranged in two hexagons comprising seven electrodes each. Cortical responses from Areas 17/18 were acquired using a silicon-based, multi-channel, penetrating probe developed at IMTEK, University of Freiburg, within the European research project NeuroProbes. Multi-unit spike activity was recorded in synchrony with the presentation of electrical stimuli. Results show that distinct cortical response patterns could be elicited from each hexagon separated by 1.8 mm (center-to-center) with a center-to-center electrode spacing within each hexagon of 0.55 mm. This lends support that higher spatial resolution may also be discerned.

[1]  P. Preston,et al.  In-Vitro Testing of Simultaneous Charge Injection and Recovery in a Retinal Neuroprosthesis , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[2]  G. Brindley The passive electrical properties of the frog's retina, choroid and sclera for radial fields and currents , 1956, The Journal of physiology.

[3]  O. Paul,et al.  Microprobe Array with Low Impedance Electrodes and Highly Flexible Polyimide Cables for Acute Neural Recording , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  K. Horch,et al.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array , 1991, IEEE Transactions on Biomedical Engineering.

[5]  Patrick Ruther,et al.  Fabrication technology for silicon-based microprobe arrays used in acute and sub-chronic neural recording , 2009 .

[6]  R. J. Vetter,et al.  Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[7]  M. Murakami,et al.  On the R Membrane in the Frog's Eye: Its Localization, and Relation to the Retinal Action Potential , 1960, The Journal of general physiology.

[8]  G. Suaning,et al.  Finite Element Bidomain Model of Epiretinal Stimulation , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  N H Lovell,et al.  A CMOS retinal neurostimulator capable of focussed, simultaneous stimulation , 2009, Journal of neural engineering.

[10]  G. J. Suaning,et al.  Focal activation of the feline retina via a suprachoroidal electrode array , 2009, Vision Research.

[11]  D. Hubel,et al.  Receptive fields of single neurones in the cat's striate cortex , 1959, The Journal of physiology.

[12]  Takashi Fujikado,et al.  Electrophysiological studies of the feasibility of suprachoroidal-transretinal stimulation for artificial vision in normal and RCS rats. , 2004, Investigative ophthalmology & visual science.