Application of MOSFET Detectors for Dosimetry in Small Animal Radiography Using Short Exposure Times

Abstract Lin, M. D., Toncheva, G., Nguyen, G., Kim, S., Anderson-Evans, C., Johnson, G. A. and Yoshizumi, T. T. Application of MOSFET Detectors for Dosimetry in Small Animal Radiography Using Short Exposure Times. Radiat. Res. 170, 260– 263 (2008). Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies.

[1]  Ehsan Samei,et al.  Optimized radiographic spectra for small animal digital subtraction angiography. , 2006, Medical physics.

[2]  Kai Rothkamm,et al.  Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[3]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[4]  J Cygler,et al.  Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter. , 1994, Medical physics.

[5]  S M Seltzer,et al.  AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology. , 2001, Medical physics.

[6]  G. Allan Johnson,et al.  A High-Precision Contrast Injector for Small Animal X-Ray Digital Subtraction Angiography , 2008, IEEE Transactions on Biomedical Engineering.

[7]  Donald P. Frush,et al.  Conventional and CT angiography in children: dosimetry and dose comparisons , 2006, Pediatric Radiology.

[8]  D. Frush,et al.  MOSFET dosimetry for radiation dose assessment of bismuth shielding of the eye in children. , 2007, AJR. American journal of roentgenology.

[9]  R. Close,et al.  X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature. , 2000, Medical physics.

[10]  D. Frush,et al.  Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry. , 2007, AJR. American journal of roentgenology.

[11]  P. R. Moran,et al.  A multiple image subtraction technique for enhancing low contrast, periodic objects. , 1973, Investigative radiology.

[12]  S. Evans Catalogue of Diagnostic X-Ray Spectra and Other Data , 1998 .

[13]  MK Woo,et al.  Commissioning and evaluation of a new commercial small rodent x-ray irradiator , 2006, Biomedical imaging and intervention journal.

[14]  J. Rownd,et al.  Clinical implementation of AAPM TG61 protocol for kilovoltage x-ray beam dosimetry. , 2002, Medical physics.