Effectiveness of fluid-viscous dampers for improved seismic performance of inter-storey isolated buildings

Abstract The use of fluid viscous dampers (FVDs) together with isolators, frequent in near-fault buildings, is effective in reducing displacements of the isolation layer. Such a hybrid system is also beneficial in the case of inter-storey isolation with the aim of limiting P-Δ effects. However, previous research on base isolation shows that this additional damping may also be detrimental, as inter-storey drifts and floor accelerations may increase. This paper analyses the effectiveness of FVDs for enhanced seismic performance of systems with inter-storey isolation. A seven-floor building, with natural and lead rubber bearings between the second and third levels, was used as a case study, and a multi-objective optimal design was performed to identify the best damper parameters. In particular, time-history analyses with various natural records were carried out and two competing objectives were examined: minimisation of the deflection of the isolation layer and minimisation of the total drift of the superstructure. The results show not only the effectiveness of optimal FVDs but also the fact that their optimal linearity degree depends to a great extent on the non-linear seismic response of the structure, i.e., on the type of earthquake. The simplest design approach, consisting of applying an optimization algorithm for each design accelerogram, did not seem, in this case, to be sufficient to identify the best overall design solution. The design consequences of these findings are discussed.

[1]  Henri P. Gavin,et al.  A parametric study of linear and non-linear passively damped seismic isolation systems for buildings , 2004 .

[2]  John F. Hall,et al.  The role of damping in seismic isolation , 1999 .

[3]  Mansour Ziyaeifar,et al.  Partial mass isolation in tall buildings , 1998 .

[4]  Kung-Chun Lu,et al.  System identification of mid‐story isolation building using both ambient and earthquake response data , 2013 .

[5]  Gary B. Lamont,et al.  Evolutionary Algorithms for Solving Multi-Objective Problems (Genetic and Evolutionary Computation) , 2006 .

[6]  R. S. Jangid,et al.  Base isolation for near‐fault motions , 2001 .

[7]  Q. Zhou,et al.  Model reduction and optimal parameters of mid-story isolation systems , 2016 .

[8]  James M. Kelly,et al.  The role of damping in seismic isolation , 1999 .

[9]  Ioannis V. Kalpakidis Effects of heating and load history on the behavior of lead -rubber bearings , 2008 .

[10]  John B. Mander,et al.  Innovative seismic retrofitting strategy of added stories isolation system , 2013 .

[11]  Michael C. Constantinou,et al.  Effect of viscous damping devices on the response of seismically isolated structures , 2015 .

[12]  Anil K. Chopra,et al.  Earthquake response of elastic SDF systems with non‐linear fluid viscous dampers , 2002 .

[13]  Costas P. Providakis,et al.  Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations , 2008 .

[14]  L. J. Leu,et al.  Optimal Allocation of Non-Linear Viscous Dampers for Three-Dimensional Building Structures , 2011 .

[15]  Anna Reggio,et al.  Optimal energy‐based seismic design of non‐conventional Tuned Mass Damper (TMD) implemented via inter‐story isolation , 2015 .

[16]  Pacific Earthquake,et al.  Effect of Damping Mechanisms on the Response of Seismically Isolated Structures , 1998 .

[17]  Kalyanmoy Deb,et al.  A fast and elitist multiobjective genetic algorithm: NSGA-II , 2002, IEEE Trans. Evol. Comput..

[18]  Andrea Dall'Asta,et al.  Probabilistic seismic response assessment of linear systems equipped with nonlinear viscous dampers , 2015 .

[19]  George C. Manos,et al.  A knowledge-based software for the preliminary design of seismically isolated bridges , 2012, Bulletin of Earthquake Engineering.

[20]  Nobuyuki Mori,et al.  Applying Seismic Isolation to Buildings in Japan — Retrofitting and Middle-Story Isolation , 2008 .

[21]  Costas P. Providakis,et al.  Effect of supplemental damping on LRB and FPS seismic isolators under near-fault ground motions , 2009 .

[22]  Ioannis Politopoulos,et al.  A review of adverse effects of damping in seismic isolation , 2008 .

[23]  Nicos Makris,et al.  RIGIDITY–PLASTICITY–VISCOSITY: CAN ELECTRORHEOLOGICAL DAMPERS PROTECT BASE‐ISOLATED STRUCTURES FROM NEAR‐SOURCE GROUND MOTIONS? , 1997 .

[24]  Neda Darivandi,et al.  The design of an optimal viscous damper for a bridge stay cable using energy-based approach , 2010 .

[25]  Keri L. Ryan,et al.  Problems with Rayleigh Damping in Base-Isolated Buildings , 2008 .

[26]  Mohamed A. ElGawady,et al.  Appropriate viscous damping for nonlinear time‐history analysis of base‐isolated reinforced concrete buildings , 2013 .

[27]  Gary B. Lamont,et al.  Evolutionary Algorithms for Solving Multi-Objective Problems , 2002, Genetic Algorithms and Evolutionary Computation.

[28]  Ruiyang Zhang,et al.  Shake table real‐time hybrid simulation techniques for the performance evaluation of buildings with inter‐story isolation , 2017 .

[29]  Dimos C. Charmpis,et al.  Optimized retrofit of multi-storey buildings using seismic isolation at various elevations: assessment for several earthquake excitations , 2015, Bulletin of Earthquake Engineering.

[30]  Jian Zhang,et al.  Optimal Design of Seismic Protective Devices for Highway Bridges Using Performance-Based Methodology and Multiobjective Genetic Optimization , 2017 .

[31]  Fu Lin Zhou Seismic isolation of civil buildings in the People's Republic of China , 2001 .

[32]  F. Ikhouane,et al.  Variation of the hysteresis loop with the Bouc–Wen model parameters , 2007 .

[33]  Kuo-Chun Chang,et al.  Simplified analysis of mid‐story seismically isolated buildings , 2011 .

[34]  Dimos C. Charmpis,et al.  Optimized earthquake response of multi-storey buildings with seismic isolation at various elevations , 2012 .

[35]  Wen Guang Liu,et al.  NEW SEISMIC ISOLATION SYSTEM FOR IRREGULAR STRUCTURE WITH THE LARGEST ISOLATION BUILDING AREA IN THE WORLD , 2002 .

[36]  Mojtaba Fathi,et al.  Effect of supplemental damping on seismic response of base isolated frames under near & far field accelerations , 2015 .

[37]  Thambirajah Balendra,et al.  Seismic response of base isolated buildings including p‐Δ effects of isolation bearings , 1989 .

[38]  Francesca da Porto,et al.  Experimental characterization, design and modelling of the RBRL seismic‐isolation system for lightweight structures , 2017 .

[39]  Marco Donà Rolling-Ball Rubber-Layer system for the lightweight structures seismic protection: experimentation and numerical analyses , 2015 .

[40]  Bing Han,et al.  Optimal parameters of viscous damper for hanged cables in arch bridges , 2016 .

[41]  Keri L. Ryan,et al.  Isolated Buildings and the 1997 UBC Near-Source Factors , 2000 .

[42]  Mohammed Ismail,et al.  The Hysteresis Bouc-Wen Model, a Survey , 2009 .