Validation of a Multimodality Flow Phantom and Its Application for Assessment of Dynamic SPECT and PET Technologies

Simple and robust techniques are lacking to assess performance of flow quantification using dynamic imaging. We therefore developed a method to qualify flow quantification technologies using a physical compartment exchange phantom and image analysis tool. We validate and demonstrate utility of this method using dynamic PET and SPECT. Dynamic image sequences were acquired on two PET/CT and a cardiac dedicated SPECT (with and without attenuation and scatter corrections) systems. A two-compartment exchange model was fit to image derived time-activity curves to quantify flow rates. Flowmeter measured flow rates (20-300 mL/min) were set prior to imaging and were used as reference truth to which image derived flow rates were compared. Both PET cameras had excellent agreement with truth (r2> 0.94). High-end PET had no significant bias (p > 0.05) while lower-end PET had minimal slope bias (wash-in and wash-out slopes were 1.02 and 1.01) but no significant reduction in precision relative to high-end PET (<;15% vs. <;14% limits of agreement, p > 0.3). SPECT (without scatter and attenuation corrections) slope biases were noted (0.85 and 1.32) and attributed to camera saturation in early time frames. Analysis of wash-out rates from non-saturated, late time frames resulted in excellent agreement with truth (r2= 0.98, slope = 0.97). Attenuation and scatter corrections did not significantly impact SPECT performance. The proposed phantom, software and quality assurance paradigm can be used to qualify imaging instrumentation and protocols for quantification of kinetic rate parameters using dynamic imaging.

[1]  Ernst Klotz,et al.  A Biological Phantom for Contrast-Media-Based Perfusion Studies With CT , 2009, Investigative radiology.

[2]  D Balvay,et al.  Perfusion and vascular permeability: basic concepts and measurement in DCE-CT and DCE-MRI. , 2013, Diagnostic and interventional imaging.

[3]  Ran Klein,et al.  Quantification of myocardial blood flow and flow reserve: Technical aspects , 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[4]  P. Slomka,et al.  Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study , 2013, The Journal of Nuclear Medicine.

[5]  C Coolens,et al.  Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT. , 2011, Medical physics.

[6]  T. K. Natarajan,et al.  Construcion of a functional image from spatially localized rate constants obtained from serial camera and rectilinear scanner data. , 1969, Radiology.

[7]  A Adler,et al.  Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography , 2007, Physics in Medicine and Biology.

[8]  M. Henzlova,et al.  Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera , 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[9]  Feng Wang,et al.  68Ga-DOTA-NGR as a novel molecular probe targeting APN/CD13 for tumor angiogenesis imaging , 2013 .

[10]  Andrew Paulsen,et al.  Adsorption of 99mTc-Sestamibi onto Plastic Syringes: Evaluation of Factors Affecting the Degree of Adsorption and Their Impact on Clinical Studies* , 2013, The Journal of Nuclear Medicine Technology.

[11]  Ran Klein,et al.  Short-term repeatability of resting myocardial blood flow measurements using rubidium-82 PET imaging , 2012, Journal of Nuclear Cardiology.

[12]  C Coolens,et al.  Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation. , 2013, Medical physics.

[13]  A J Hindle,et al.  A perfusion phantom for the evaluation of ultrasound contrast agents. , 1994, Ultrasound in medicine & biology.

[14]  Hubert Cochet,et al.  Absolute Quantification of Left Ventricular Global and Regional Function at Nuclear MPI Using Ultrafast CZT SPECT : Initial Validation Versus Cardiac MR , 2013 .

[15]  Parthiban Arumugam,et al.  Assessment of a protocol for routine simultaneous myocardial blood flow measurement and standard myocardial perfusion imaging with rubidium-82 on a high count rate positron emission tomography system , 2012, Nuclear medicine communications.

[16]  Ran Klein,et al.  Dynamic SPECT Measurement of Absolute Myocardial Blood Flow in a Porcine Model , 2014, The Journal of Nuclear Medicine.

[17]  J. Bartlett,et al.  Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables , 2008, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[18]  V. Bettinardi,et al.  Physical performance of the new hybrid PET∕CT Discovery-690. , 2011, Medical physics.

[19]  R A Robb,et al.  X-ray computed tomographic (CT) phantom designed for the development of techniques for measurement of myocardial perfusion. , 1991, Physics in medicine and biology.

[20]  G. Hutchins,et al.  A region of interest strategy for minimizing resolution distortions in quantitative myocardial PET studies. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  Behzad Ebrahimi,et al.  A Microfabricated Phantom for Quantitative MR Perfusion Measurements: Validation of Singular Value Decomposition Deconvolution Method , 2010, IEEE Transactions on Biomedical Engineering.

[22]  Wen-Sheng Huang,et al.  Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease , 2014, European Journal of Nuclear Medicine and Molecular Imaging.

[23]  Andy Adler,et al.  Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program , 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[24]  Wen-Sheng Huang,et al.  Feasibility and operator variability of myocardial blood flow and reserve measurements with 99mTc-sestamibi quantitative dynamic SPECT/CT imaging , 2014, Journal of Nuclear Cardiology.

[25]  Leonid Tsukerman,et al.  A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[26]  Ernest V Garcia Are absolute myocardial blood flow PET measurements ready for clinical use? , 2014, Journal of Nuclear Cardiology.

[27]  Robert A. deKemp,et al.  Quantification of myocardial perfusion: What will it take to make it to prime time? , 2009 .

[28]  David Gilmore,et al.  Residual syringe activity: Is there a need for concern? , 2010 .

[29]  Amir Pourmoghaddas,et al.  Scatter correction improves concordance in SPECT MPI with a dedicated cardiac SPECT solid-state camera , 2015, Journal of Nuclear Cardiology.

[30]  Timothy G. Turkington,et al.  Characterization of 3 D PET systems for accurate quantification of myocardial blood , 2016 .

[31]  R. Boellaard Standards for PET Image Acquisition and Quantitative Data Analysis , 2009, Journal of Nuclear Medicine.