Advanced Low-Noise X-Ray Readout ASIC for Radiation Sensor Interfaces

A VLSI readout front-end architecture, dedicated for X-ray imaging, using specific capacitive silicon detectors, with capacitance ranging from 2 to 10 pF, is described. Critical design issues such as the noise optimization and the shaper implementation technique are addressed and the first performance - test results of a fabricated prototype in a 0.35-mum 3.3-V CMOS process, are presented. Important feature of the design is the novel CR - RC2 pulse-shaper configuration since in this section, transconductor circuits are used in order to provide a broad range of continuous variable peaking time, programmable gain and adjustable undershoot while still maintaining the noise performance and the required linearity of the specific radiation detection application. Regarding the readout ASIC performance characteristics, the power consumption is 1 mW per channel, the equivalent noise charge at 1.81-mus peaking time is 382 e- plus 21 e- per picofrard of detector capacitance. The topology achieves a conversion gain equal to 3.31 mV/fC and a linearity of 0.69%.

[1]  E. Delagnes,et al.  IDeF-X ASIC for Cd(Zn)Te spectro-imaging systems , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[2]  Jan Kaplon,et al.  Fast CMOS binary front end for silicon strip detectors at LHC experiments , 2005 .

[3]  Marco Sampietro,et al.  ‘R-lens filter’: An (RC)n current-mode lowpass filter , 1999 .

[4]  Dirk Meier,et al.  A readout ASIC for SPECT , 2005 .

[5]  D. Landis,et al.  Signal Processing for Semiconductor Detectors , 1982, IEEE Transactions on Nuclear Science.

[6]  Antonio Francesco Longoni,et al.  Design of a charge sensitive preamplifier on high resistivity silicon , 1988 .

[7]  Heike Soltau,et al.  Silicon drift detectors for high resolution room temperature X-ray spectroscopy , 1996 .

[8]  Massimo Manghisoni,et al.  Integrated front-end electronics in a detector compatible process: source-follower and charge-sensitive preamplifier configurations , 2001, SPIE Optics + Photonics.

[9]  Arie F. Arbel,et al.  Analog signal processing and instrumentation , 1980 .

[10]  Gad Shani Electronics for radiation measurements , 1996 .

[11]  L. Fabris,et al.  Optimization of front-end design in imaging and spectrometry applications with room temperature semiconductor detectors , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[12]  Cleve Moler,et al.  Mathematical Handbook for Scientists and Engineers , 1961 .

[13]  G. Bertuccio,et al.  Implanted silicon JFET on completely depleted high-resistivity devices , 1989, IEEE Electron Device Letters.

[14]  Willy Sansen,et al.  Effect of noise on the resolution of CMOS analog readout systems for microstrip and pixel detectors , 1991 .

[15]  F. Prino,et al.  RX64DTH - a fully integrated 64-channel ASIC for digital X-ray imaging system with energy window selection , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[16]  B. Krieger,et al.  PETRIC - A positron emission tomography readout integrated circuit , 2000 .

[17]  Paul O'Connor,et al.  Prospects for charge sensitive amplifiers in scaled CMOS , 2002 .

[18]  Paul O'Connor,et al.  A generation of CMOS readout ASICs for CZT detectors , 1999 .

[19]  M. E. Valkenburg,et al.  Design of Analog Filters , 2001 .

[20]  Willy Sansen,et al.  Limits of low noise performance of detector readout front ends in CMOS technology , 1990 .

[21]  David A. Johns,et al.  Analog Integrated Circuit Design , 1996 .

[22]  B. Krieger,et al.  An 8/spl times/8 pixel IC for X-ray spectroscopy , 2001 .

[23]  Adel S. Sedra,et al.  Filter Theory and Design: Active and Passive , 1977 .

[24]  K. Husimi,et al.  Direct synthesis of the Gaussian filter for nuclear pulse amplifiers , 1976 .

[25]  S. Siskos,et al.  Programmable OTA Based CMOS Shaping Amplifier for X-rays Spectroscopy , 2006, 2006 Ph.D. Research in Microelectronics and Electronics.

[26]  M. Konrad,et al.  Detector Pulse Shaping for High Resolution Spectroscopy , 1968 .

[27]  J. Lund,et al.  Epitaxial n-channel JFETs integrated on high resistivity silicon for X-ray detectors , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.

[28]  R. L. Chase,et al.  8-channel CMOS preamplifier and shaper with adjustable peaking time and automatic pole-zero cancellation , 1998 .

[29]  Veljko Radeka,et al.  Optimum Signal-Processing for Pulse-Amplitude Spectrometry in the Presence of High-Rate Effects and Noise , 1968 .

[30]  Effect of technology on the input transistor selection criteria of a low noise preamplifier , 2004, Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521).

[31]  Yichuang Sun,et al.  Continuous-Time Active Filter Design , 1998 .

[32]  Willy M. C. Sansen,et al.  Low-noise wide-band amplifiers in bipolar and CMOS technologies , 1990, The Kluwer international series in engineering and computer science.