Evaluation of simplified models for predicting CO2 concentrations in small commercial buildings

Evaluation of a building for application of demand-controlled ventilation (DCV) typically involves the use of computer simulations to predict energy use/costs for both fixed ventilation and ventilation adjusted to maintain fixed CO2 levels within the space. The simulation tools incorporate models for predicting CO2 concentrations in response to internal sources (people), infiltration/exfiltration, and ventilation. This paper presents a detailed evaluation of different modeling approaches for predicting levels of CO2 in occupied spaces for small, single-zone commercial buildings employing packaged air-conditioning equipment. Two-zone and three-zone transient models were compared with a quasi-static equilibrium model applied to three distinctly different building types. Baseline data were derived from computational fluid dynamic models that were developed for field sites. A complete building system simulation model was then used to compare the impact of the different modeling approaches on the predicted energy cost savings associated with application of DCV in each building type. The use of a transient CO2 model did not have a significant impact on model prediction accuracy and energy cost savings predictions as compared with the quasi-static model. The difference in predicted annual energy costs between the various CO2 modeling types were small and less than might result from errors introduced by factors such as CO2 sensor uncertainty. Therefore, the use of an equilibrium model is sufficient for use in evaluating DCV for small commercial buildings.

[1]  M. J. Brandemuehl,et al.  The impact of demand-controlled and economizer ventilation strategies on energy use in buildings , 1999 .

[2]  James E. Braun,et al.  A methodology for estimating occupant CO2 source generation rates from measurements in small commercial buildings , 2007 .

[3]  J. D. Wenger,et al.  Ventilation air flow measurement for ASHRAE standard 62-1989 , 1992 .

[4]  Syogo Ogasawara,et al.  Effect of energy conservation by controlled ventilation: Case study in a department store , 1979 .

[5]  Andrew K. Persily,et al.  A study of ventilation and carbon dioxide in an office building , 1994 .

[6]  Mike Schell,et al.  Assessing CO~2 Control in Retrofits , 2002 .

[7]  M. B. Schell,et al.  Application of CO{sub 2}-based demand-controlled ventilation using ASHRAE Standard 62: Optimizing energy use and ventilation , 1998 .

[8]  Andrew K. Persily Ventilation, carbon dioxide and ASHRAE standard 62-1989 , 1993 .

[9]  C. C. Federspiel Conditions for the Input-Output Relation of Perfect-Mixing Processes to be First Order With Application to Building Ventilation Systems , 1998 .

[10]  S. Emmerich,et al.  State-Of-The-Art Review of Co2 Demand Controlled Ventilation Technology and Application , 2003 .

[11]  Clifford Federspiel,et al.  Estimating the inputs of gas transport processes in buildings , 1997, IEEE Trans. Control. Syst. Technol..

[12]  W. Fisk,et al.  Association of ventilation rates and CO2 concentrations with health and other responses in commercial and institutional buildings. , 1999, Indoor air.

[13]  J. E. Janssen,et al.  Ventilation for control of indoor air quality: A case study , 1982 .

[14]  C. G. Nesler,et al.  Strategies for outdoor airflow control from a systems perspective , 1995 .