High-Resolution Quantitative Imaging of Cornea Elasticity Using Supersonic Shear Imaging

The noninvasive estimation of in vivo mechanical properties of cornea is envisioned to find several applications in ophthalmology. Such high-resolution measurements of local cornea stiffness could lead to a better anticipation and understanding of corneal pathologies such as Keratoconus. It could also provide a quantitative evaluation of corneal biomechanical response after corneal refractive surgeries and a tool for evaluating the efficacy of new cornea treatments such as cornea transplant using femtosecond laser or therapy based on Riboflavin/UltraViolet-A Corneal Cross Linking (UVA CXL). In the very important issue of glaucoma diagnosis and management, the fine tuning corneal elasticity measurement could also succeed to strongly correlate the applanation tonometry with the "true" intra-ocular pressure (IOP). This initial investigation evaluates the ability of ultrafast and high-resolution ultrasonic systems to provide a real-time and quantitative mapping of corneal viscoelasticity. Quantitative elasticity maps were acquired ex vivo on porcine cornea using the supersonic shear imaging (SSI) technique. A conventional 15 MHz linear probe was used to perform conventional ultrasonic imaging of the cornea. A dedicated ultrasonic sequence combines the generation of a remote palpation in the cornea and ultrafast (20 000 frames/s) ultrasonic imaging of the resulting corneal displacements that evolve into a shear wave propagation whose local speed was directly linked to local elasticity. A quantitative high-resolution map (150 mum resolution) of local corneal elasticity can be provided by this dedicated sequence of ultrasonic insonifications. Quantitative maps of corneal elasticity were obtained on ex vivo freshly enucleated porcine corneas. In the cornea, a quite homogenous stiffness map was found with a 190 kPa +/ - 32 kPa mean elasticity. The influence of photodynamic Riboflavin/UVA induced CXL was measured. A significant Young's modulus increase was obtained with a mean 890 kPa + / - 250 kPa posttreatment Young's modulus (460% increase), located in the anterior part of the cornea. Simulations based on 3-D time domain finite differences simulation were also performed and found to be in good agreement with ex vivo experiments. The SSI technique can perform real-time, noninvasive, high-resolution, and quantitative maps of the whole corneal elasticity. This technique could be real time and straightforward adapted for a very wide field of in vivo investigations.

[1]  B Jean,et al.  Dynamic mechanical spectroscopy of the cornea for measurement of its viscoelastic properties in vitro. , 1995, German journal of ophthalmology.

[2]  Panagiotis Samaras,et al.  Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitis. , 2007, AJR. American journal of roentgenology.

[3]  T. Seiler,et al.  Stress‐strain measurements of human and porcine corneas after riboflavin–ultraviolet‐A‐induced cross‐linking , 2003, Journal of cataract and refractive surgery.

[4]  Eberhard Spoerl,et al.  Biomechanical evidence of the distribution of cross‐links in corneastreated with riboflavin and ultraviolet A light , 2006, Journal of cataract and refractive surgery.

[5]  C. D. de Korte,et al.  Intravascular ultrasound elastography in human arteries: initial experience in vitro. , 1998, Ultrasound in medicine & biology.

[6]  William J Dupps,et al.  Biomechanical modeling of corneal ectasia. , 2005, Journal of refractive surgery.

[7]  L. Molotkov,et al.  Low-frequency lamb waves in cylindrical and spherical layers in an elastic medium , 1975 .

[8]  William J Dupps,et al.  Surface wave elastometry of the cornea in porcine and human donor eyes. , 2007, Journal of refractive surgery.

[9]  G R Sutherland,et al.  Can natural strain and strain rate quantify regional myocardial deformation? A study in healthy subjects. , 2001, Ultrasound in medicine & biology.

[10]  D. Pye,et al.  Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo , 1999, Bulletin of mathematical biology.

[11]  Ahmed Elsheikh,et al.  Determination of the modulus of elasticity of the human cornea. , 2007, Journal of refractive surgery.

[12]  Perry S Binder,et al.  Analysis of ectasia after laser in situ keratomileusis: Risk factors , 2007, Journal of cataract and refractive surgery.

[13]  Ecosse Lamoureux,et al.  A randomized controlled trial of corneal collagen cross-linking in progressive keratoconus: preliminary results. , 2008, Journal of refractive surgery.

[14]  B. Garra,et al.  Elastography of breast lesions: initial clinical results. , 1997, Radiology.

[15]  Thomas Deffieux,et al.  Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity , 2009, IEEE Transactions on Medical Imaging.

[16]  I. Cunliffe,et al.  Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. , 2007, Investigative ophthalmology & visual science.

[17]  J. Ophir,et al.  Myocardial elastography--a feasibility study in vivo. , 2002, Ultrasound in medicine & biology.

[18]  G. Kymionis,et al.  Corneal crosslinking with riboflavin and UVA for the treatment of keratoconus. , 2007, Journal of cataract and refractive surgery.

[19]  M. Ziol,et al.  Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. , 2003, Ultrasound in medicine & biology.

[20]  H. Lamb On waves in an elastic plate , 1917 .

[21]  Mickael Tanter,et al.  The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  G. Mourou,et al.  Applications of femtosecond lasers in corneal surgery , 2000 .

[23]  Mickael Tanter,et al.  Sonic boom in soft materials: The elastic Cerenkov effect , 2004 .

[24]  J. Randall,et al.  Brillouin scattering, density and elastic properties of the lens and cornea of the eye , 1980, Nature.

[25]  Jean-Pierre Berenger,et al.  A perfectly matched layer for the absorption of electromagnetic waves , 1994 .

[26]  J Bercoff,et al.  In vivo breast tumor detection using transient elastography. , 2003, Ultrasound in medicine & biology.

[27]  N Bom,et al.  Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro. , 2000, Circulation.

[28]  Claudio Traversi,et al.  Parasurgical therapy for keratoconus by riboflavin–ultraviolet type A rays induced cross‐linking of corneal collagen: Preliminary refractive results in an Italian study , 2006, Journal of cataract and refractive surgery.

[29]  J. Virieux P-SV wave propagation in heterogeneous media: Velocity‐stress finite‐difference method , 1986 .

[30]  J Bercoff,et al.  Monitoring Thermally-Induced Lesions with Supersonic Shear Imaging , 2004, Ultrasonic imaging.

[31]  D. Royer,et al.  Elastic waves in solids , 1980 .

[32]  M. Fink,et al.  Assessment of the mechanical properties of the musculoskeletal system using 2-D and 3-D very high frame rate ultrasound , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  Jun Liu,et al.  Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis , 2005, Journal of cataract and refractive surgery.

[34]  M K Smolek,et al.  Interlamellar cohesive strength in the vertical meridian of human eye bank corneas. , 1993, Investigative ophthalmology & visual science.

[35]  M. Lawless,et al.  Progressive post‐LASIK keratectasia: Biomechanical instability or chronic disease process? , 2002, Journal of cataract and refractive surgery.

[36]  M. Fink,et al.  Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[37]  M. Fink,et al.  Quantitative viscoelasticity mapping of human liver using supersonic shear imaging: preliminary in vivo feasibility study. , 2009, Ultrasound in medicine & biology.

[38]  P. McDonnell,et al.  An ultrasonic technique for the measurement of the elastic moduli of human cornea. , 1996, Journal of biomechanics.

[39]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[40]  M. Fink,et al.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[41]  Matthew O'Donnell,et al.  Strain Imaging of Corneal Tissue With an Ultrasound Elasticity Microscope , 2002, Cornea.

[42]  L. Nordan,et al.  Keratoconus: Diagnosis and Treatment , 1997, International ophthalmology clinics.

[43]  Jonas S. Friedenwald,et al.  Contribution to the Theory and Practice of Tonometry , 1937 .

[44]  Eberhard Spoerl,et al.  Collagen crosslinking of human and porcine sclera , 2004, Journal of cataract and refractive surgery.

[45]  Gerard Mourou,et al.  Femtosecond Lasers for Ultra-Accurate Surgery: Application to Corneal Surgery , 1998 .

[46]  G. Mourou,et al.  Corneal refractive surgery with femtosecond lasers , 1999 .

[47]  Theo Seiler,et al.  Increased resistance of crosslinked cornea against enzymatic digestion , 2004, Current eye research.

[48]  Christos Christidis,et al.  Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C , 2005, Hepatology.

[49]  Thomas Deffieux,et al.  Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging. , 2008, Ultrasound in medicine & biology.

[50]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.