Detached eddy simulation of pedestrian-level wind and gust around an elevated building

Abstract Wind flow turbulence is known to have a major influence on the pedestrian-level wind (PLW) environments, particularly around a building. The elevated design of a building, as a special feature, proved to improve pedestrian-level weak wind conditions in high-density cities. The present study aims to assess three turbulence models, the detached eddy simulation (DES), the steady-state RANS (SRANS), and the unsteady-state RANS (URANS), in their simulation of the PLW flow turbulence concerning wind gust. The simulated mean wind velocities around isolated buildings with and without an elevated design were compared with those obtained from a wind tunnel experiment. The effects of mesh resolution and inflow fluctuating algorithm on the performance of the DES model were thoroughly evaluated. The DES model can better reproduce the mean flow fields than the other two models. Finally, the unsteady fluctuations of wind flow around the buildings with and without the elevated design are analyzed in terms of instantaneous wind velocity, lift coefficient, energy spectral density, and turbulence intensity. The predicted lift coefficient and Strouhal number are approximately 0.01 and 0.09, respectively, which is consistent with what are reported in the literature. Modifications of the frequency of vortex shedding, periodical wind flow pattern, and the normalized wind gust flow fields around the two types of buildings are compared in detail. The work reveals that transient turbulent flow pattern can be reasonably obtained with the DES model, indicating the potential of using the DES for PLW gust assessments in urban planning.

[1]  P. Spalart Comments on the feasibility of LES for wings, and on a hybrid RANS/LES approach , 1997 .

[2]  Jianlei Niu,et al.  CFD simulation of the wind environment around an isolated high-rise building: An evaluation of SRANS, LES and DES models , 2016 .

[3]  Akashi Mochida,et al.  Prediction of wind environment and thermal comfort at pedestrian level in urban area , 2006 .

[4]  Jean-Pierre Bertoglio,et al.  Assessment of the vortex method for Large Eddy Simulation inlet conditions , 2006 .

[5]  Borong Lin,et al.  Numerical studies of the outdoor wind environment and thermal comfort at pedestrian level in housing blocks with different building layout patterns and trees arrangement , 2015 .

[6]  E. Ng Policies and technical guidelines for urban planning of high-density cities – air ventilation assessment (AVA) of Hong Kong , 2008, Building and Environment.

[7]  Yoshihide Tominaga,et al.  AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings , 2008 .

[8]  Gavin Tabor,et al.  Inlet conditions for large eddy simulation: A review , 2010 .

[9]  Qiusheng Li,et al.  Numerical evaluation of wind effects on a tall steel building by CFD , 2007 .

[10]  Kenny C. S Kwok,et al.  Adopting ‘lift-up’ building design to improve the surrounding pedestrian-level wind environment , 2017, Building and Environment.

[11]  Cheuk Ming Mak,et al.  Large-eddy Simulation of flow and dispersion around an isolated building: Analysis of influencing factors , 2015 .

[12]  Qiusheng Li,et al.  Inflow turbulence generation methods with large eddy simulation for wind effects on tall buildings , 2015 .

[13]  Yue Zhang,et al.  Predicting wind-induced vibrations of high-rise buildings using unsteady CFD and modal analysis , 2015 .

[14]  Kenny C. S Kwok,et al.  Large eddy simulation of flow around an inclined finite square cylinder , 2015 .

[15]  Bje Bert Blocken,et al.  Pedestrian-level wind conditions around buildings: Review of wind-tunnel and CFD techniques and their accuracy for wind comfort assessment , 2016 .

[16]  Ismail Celik,et al.  Index of resolution quality for large eddy simulations , 2005 .

[17]  S. Orszag,et al.  Renormalization group analysis of turbulence. I. Basic theory , 1986 .

[18]  Kenny C. S Kwok,et al.  Effects of building lift-up design on the wind environment for pedestrians , 2017 .

[19]  Borong Lin,et al.  Numerical simulation studies of the different vegetation patterns' effects on outdoor pedestrian thermal comfort , 2006 .

[20]  P. Höppe,et al.  The physiological equivalent temperature – a universal index for the biometeorological assessment of the thermal environment , 1999, International journal of biometeorology.

[21]  Kenny C. S Kwok,et al.  A new method to assess spatial variations of outdoor thermal comfort: Onsite monitoring results and implications for precinct planning , 2015 .

[22]  Fotis Sotiropoulos,et al.  Detached eddy simulation of flow around two wall-mounted cubes in tandem , 2009 .

[23]  Y. Tominaga Flow around a high-rise building using steady and unsteady RANS CFD: Effect of large-scale fluctuations on the velocity statistics , 2015 .

[24]  W. H. Melbourne,et al.  Criteria for environmental wind conditions , 1978 .

[25]  George Havenith,et al.  UTCI—Why another thermal index? , 2011, International Journal of Biometeorology.

[26]  Theodore Stathopoulos,et al.  Application of computational fluid dynamics in building performance simulation for the outdoor environment: an overview , 2011 .

[27]  V. Dorer,et al.  Urban Physics: Effect of the micro-climate on comfort, health and energy demand , 2012 .

[28]  S. Murakami,et al.  Comparison of various revised k–ε models and LES applied to flow around a high-rise building model with 1:1:2 shape placed within the surface boundary layer , 2008 .

[29]  Bert Blocken,et al.  Near-field pollutant dispersion in an actual urban area: Analysis of the mass transport mechanism by high-resolution Large Eddy Simulations , 2015 .

[30]  Yoshihide Tominaga,et al.  Numerical simulation of dispersion around an isolated cubic building: Comparison of various types of k–ɛ models , 2009 .

[31]  Bert Blocken,et al.  CFD evaluation of wind speed conditions in passages between parallel buildings : effect of wall-function roughness modifications for the atmospheric boundary layer flow , 2007 .

[32]  V. Cheng,et al.  Urban human thermal comfort in hot and humid Hong Kong , 2012 .

[33]  Kenny C. S Kwok,et al.  Effects of lift-up design on pedestrian level wind comfort in different building configurations under three wind directions , 2017 .

[34]  L. Berglund,et al.  A standard predictive index of human response to the thermal environment , 1986 .

[35]  Jianlei Niu,et al.  Combining measured thermal parameters and simulated wind velocity to predict outdoor thermal comfort , 2016 .

[36]  P. Spalart,et al.  A New Version of Detached-eddy Simulation, Resistant to Ambiguous Grid Densities , 2006 .

[37]  Bje Bert Blocken,et al.  Quality assessment of Large-Eddy Simulation of wind flow around a high-rise building : validation and solution verification , 2013 .