Wavelet encoding for improved SNR and retrospective slice thickness adjustment

A method to encode the slice‐select direction in magnetic resonance imaging through the use of a discrete wavelet transform is presented. The paper reports the first implementation of wavelet encoding using the Haar basis. Theoretically, the signal‐to‐noise ratio (SNR) for two levels of wavelet encoding is expected to be approximately 1.6 times higher than for conventional multislice imaging in which each slice is excited separately. A slightly lower SNR is encountered experimentally because of slice interference. The design of radiofrequency (RF) pulses to excite slices approximating Haar wavelet basis functions is discussed. Wavelet encoding also provides an efficient method for balancing slice thickness and SNR after an image has been acquired. The experiments have been conducted at 1.5 Tesla. Wavelet encoding of slices should be especially suitable for low‐field MRI, in which the SNR is lower and the characteristically lower T, values favor the use of shorter TR, which sometimes forces the slices to be acquired in multiple passes.

[1]  J. B. Weaver,et al.  Signal-to-Noise Ratios and Effective Repetition Times for Wavelet Encoding and Encoding with Wavelet Packet Bases , 1995 .

[2]  R. Meuli,et al.  Methods for reconstructing phase sensitive slice profiles in magnetic resonance imaging , 1994, Magnetic resonance in medicine.

[3]  Glyn Johnson,et al.  Improvements in performance time for simultaneous three-dimensional NMR imaging , 1983 .

[4]  J. Weaver Simultaneous multislice acquisition of MR images , 1988, Magnetic resonance in medicine.

[5]  J. Pauly,et al.  Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. , 1991, IEEE transactions on medical imaging.

[6]  J. Weaver,et al.  Wavelet‐encoded MR imaging , 1992, Magnetic resonance in medicine.

[7]  G H Glover,et al.  Phase‐offset multiplanar (POMP) volume imaging: A new technique , 1991, Journal of magnetic resonance imaging : JMRI.

[8]  L P Panych,et al.  Implementation of wavelet‐encoded MR imaging , 1993, Journal of magnetic resonance imaging : JMRI.

[9]  J Szumowski,et al.  SIMA: Simultaneous Multislice Acquisition of MR Images by Hadamard‐Encoded Excitation , 1988, Journal of computer assisted tomography.

[10]  John S. Leigh,et al.  Transverse Hadamard spectroscopic imaging technique , 1990 .

[11]  Lawrence P. Panych,et al.  Theoretical comparison of Fourier and wavelet encoding in magnetic resonance imaging , 1996, IEEE Trans. Medical Imaging.

[12]  M. L. Wood,et al.  Wavelet encoding for 3D gradient‐echo MR imaging , 1996, Magnetic resonance in medicine.

[13]  M L Wood,et al.  Multilevel wavelet‐transform encoding in MRI , 1996, Journal of magnetic resonance imaging : JMRI.

[14]  J. Tsuruda,et al.  MR sequence parameter optimization: an algorithmic approach. , 1987, AJR. American journal of roentgenology.

[15]  L P Panych,et al.  Comparing the FAISE method with conventional dual‐echo sequences , 1991, Journal of magnetic resonance imaging : JMRI.