Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Heating Season Energy and Moisture Levels

Two identical laboratory homes designed to model existing Florida building stock were sealed and tested to 2.5 ACH50. Then, one was made leaky with 70% leakage through the attic and 30% through windows, to a tested value of 9 ACH50. Reduced energy use was measured in the tighter home (2.5 ACH50) in the range of 15% to 16.5% relative to the leaky (9 ACH50) home. Internal moisture loads resulted in higher dew points inside the tight home than the leaky home. Window condensation and mold growth occurred inside the tight home. Even cutting internal moisture gains in half to 6.05 lbs/day, the dew point of the tight home was more than 15 degrees F higher than the outside dry bulb temperature. The homes have single pane glass representative of older Central Florida homes.

[1]  Philip Fairey,et al.  Updated Miscellaneous Electricity Loads and Appliance Energy Usage Profiles for Use in Home Energy Ratings, the Building America Benchmark Procedures and Related Calculations. Revised , 2011 .

[2]  X. Fang,et al.  Field Test Protocol: Standard Internal Load Generation in Unoccupied Test Homes , 2011 .

[3]  W. Fisk,et al.  Association of residential dampness and mold with respiratory tract infections and bronchitis: a meta-analysis , 2010, Environmental health : a global access science source.

[4]  Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution , 2009 .

[5]  Joseph Lstiburek,et al.  Systems Research on Residential Ventilation , 2008 .

[6]  M. Sherman,et al.  Heat recovery in building envelopes , 2003 .

[7]  D. Barley An Overview of Residential Ventilation Activities in the Building America Program (Phase I) , 2001 .

[8]  Craig P. Wray,et al.  SELECTING WHOLE-HOUSE VENTILATION STRATEGIES TO MEET PROPOSED ASHRAE STANDARD 62.2: ENERGY COST CONSIDERATIONS * , 2000 .

[9]  Judy A. Roberson,et al.  Recommended Ventilation Strategies for Energy-Efficient Production Homes , 1998 .

[10]  Francis Allard,et al.  Night ventilation for building cooling in summer , 1997 .

[11]  G. Iwashita,et al.  The effects of human behavior on natural ventilation rate and indoor air environment in summer − a field study in southern Japan , 1997 .

[12]  H. Henderson,et al.  A model to predict the latent capacity of air conditioners and heat pumps at part-load conditions with constant fan operation , 1996 .

[13]  Edward Arens,et al.  Indoor humidity and human health. Part 1: Literature review of health effects of humidity-influenced indoor pollutants , 1996 .

[14]  Max H. Sherman,et al.  Humidity Implications for Meeting Residential Ventilation Requirements , 1995 .

[15]  David E. Claridge,et al.  The Measured Energy Impact of Infiltration in a Test Cell , 1990 .

[16]  J. B. Cummings,et al.  Infiltration and pressure differences induced by forced air systems in Florida residences , 1989 .

[17]  Mark Modera,et al.  Impacts of ventilation strategies on energy consumption and indoor air quality in single-family residences , 1986 .

[18]  T. Sterling,et al.  Indirect health effects of relative humidity in indoor environments. , 1986, Environmental health perspectives.

[19]  Max H. Sherman,et al.  Variability in Residential Air Leakage , 1986 .

[20]  David T. Grimsrud,et al.  AIR INFILTRATION MEASUREMENT TECHNIQUES , 1980 .