Self Calibrating Wearable Active Running Asymmetry Measurement and Correction

We present a novel self-calibrating wearable device to improve running training by active vibro feedback. The system consists of a pair of spandex shorts embedding: a processor unit, 2 three-axial accelerometers, 2 vibro motors, a SD card reader\writer module and a real time clock. Two supplementary wireless accelerometers are located on the shoes. We present an algorithm to compute gait asymmetry from the four sensors data. The main novelty is the auto calibration algorithm which uses principal component analysis on each sensor based on kinematic assumptions. The system provides two important advantages: data logging and real time active correction. The active correction is performed sending signals to the user in real time via vibrations cells (rumble feedback). The vibration signals are sent to the specific leg and its intensity is proportional to the entity of required correction. This training system for running can be very useful to athletes and to sport medicine in order to improve speed, posture, fatigue and reduce joints osteoarthrotic problems.

[1]  Rachel Senden,et al.  Acceleration-Based Motion Analysis as a Tool for Rehabilitation: Exploration in Simulated Functional Knee Limited Walking Conditions , 2011, American journal of physical medicine & rehabilitation.

[2]  Paavo V. Komi,et al.  Fatigue effects of marathon running on neuromuscular performance , 1991 .

[3]  Sébastien Harasse,et al.  Numerical calibration for 3-axis accelerometers and magnetometers , 2009, 2009 IEEE International Conference on Electro/Information Technology.

[4]  Laurel Kincl,et al.  Validation of tri-axial accelerometer for the calculation of elevation angles , 2009 .

[5]  K. R. Williams,et al.  Changes in Distance Running Kinematics with Fatigue , 1991 .

[6]  Yongseok Jang,et al.  Designing a Vibro-Tactile Wear for "Close Range" Interaction for VR-based Motion Training , 2002 .

[7]  S. Olney,et al.  Work and power in gait of stroke patients. , 1991, Archives of physical medicine and rehabilitation.

[8]  Yanling Hao,et al.  Analysis and calibration on installation errors of accelerometer in GFSINS , 2009, 2009 Chinese Control and Decision Conference.

[9]  J Maxwell Donelan,et al.  Dynamic Principles of Gait and Their Clinical Implications , 2010, Physical Therapy.

[10]  D. Winter,et al.  Kinetic analysis of the lower limbs during walking: what information can be gained from a three-dimensional model? , 1995, Journal of biomechanics.

[11]  J. Hamill,et al.  Timing of lower extremity joint actions during treadmill running. , 1992, Medicine and science in sports and exercise.

[12]  W. Siler,et al.  Changes in running pattern during a treadmill run to volitional exhaustion , 1991 .