PRESSURE VS AIRFLOW CHARACTERISTICS THROUGH FRESH INTACT AND CUT-STRIP TOBACCO
暂无分享,去创建一个
Pressure versus airflow characteristics were determined for various densities and cut sizes of green tobacco
leaves with leaf surfaces oriented either parallel or perpendicular to the airflow. The flowrate measurement device
consisted of a fan, PVC pipe, orifice plate, sealing apparatus, and a plenum. Graphs of pressure gradient versus
superficial velocity showed a nearly linear log-log relationship. Three equations were used to fit the data: the power
equation, ASAE standard equation, and Ergun equation. The Ergun equation provided the best fit in most cases. Analysis
of variance of equation parameters with experiment variables showed that the pressure gradient was a function of the leaf
density squared. The only other factor affecting the pressure gradient was the leaf orientation. For a given velocity, leaves
oriented perpendicular to the airflow had a pressure gradient about 10 times greater than that of the leaves oriented
parallel to the airflow.