A Distribution Level Wide Area Monitoring System for the Electric Power Grid–FNET/GridEye

The wide area monitoring system (WAMS) is considered a pivotal component of future electric power grids. As a pilot WAMS that has been operated for more than a decade, the frequency monitoring network FNET/GridEye makes use of hundreds of global positioning system-synchronized phasor measurement sensors to capture the increasingly complicated grid behaviors across the interconnected power systems. In this paper, the FNET/GridEye system is overviewed and its operation experiences in electric power grid wide area monitoring are presented. Particularly, the implementation of a number of data analytics applications will be discussed in details. FNET/GridEye lays a firm foundation for the later WAMS operation in the electric power industry.

[1]  Fushuan Wen,et al.  Application of wide area measurement systems to islanding detection of bulk power systems , 2013, IEEE Transactions on Power Systems.

[2]  Yilu Liu,et al.  Frequency-based real-time line trip detection and alarm trigger development , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[3]  Yilu Liu,et al.  Impact of GPS Signal Loss and Its Mitigation in Power System Synchronized Measurement Devices , 2017, IEEE Transactions on Smart Grid.

[4]  T. Hlibka,et al.  Fundamental basis for distance relaying with symmetrical components , 1977, IEEE Transactions on Power Apparatus and Systems.

[5]  J. Quintero,et al.  Oscillation monitoring system based on wide area synchrophasors in power systems , 2007, 2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability.

[6]  Yilu Liu,et al.  A Clarke Transformation-Based DFT Phasor and Frequency Algorithm for Wide Frequency Range , 2018, IEEE Transactions on Smart Grid.

[7]  Yilu Liu,et al.  Real-time power system electromechanical mode estimation implementation and visualization utilizing synchrophasor data , 2016, 2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D).

[8]  Yong Liu,et al.  Wide-area measurement data analytics using FNET/GridEye: A review , 2016, 2016 Power Systems Computation Conference (PSCC).

[9]  A.G. Phadke,et al.  Recent developments in state estimation with phasor measurements , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[10]  Yingchen Zhang,et al.  Wide-area measurements of three nOrth America interconnections at distribution level , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[11]  Yilu Liu,et al.  A Novel Method for Phasor Measurement Unit Sampling Time Error Compensation , 2018, IEEE Transactions on Smart Grid.

[12]  Yilu Liu,et al.  Wide-area dynamic model validation using FNET measurements , 2012, 2012 IEEE PES Innovative Smart Grid Technologies (ISGT).

[13]  Yilu Liu,et al.  Frequency Disturbance Recorder Design and Developments , 2007, 2007 IEEE Power Engineering Society General Meeting.

[14]  G. Trudel,et al.  Wide-area monitoring and control at Hydro-Quebec: past, present and future , 2006, 2006 IEEE Power Engineering Society General Meeting.

[15]  Ye Zhang,et al.  Distributed Data Analytics Platform for Wide-Area Synchrophasor Measurement Systems , 2016, IEEE Transactions on Smart Grid.

[16]  Hongbin Sun,et al.  Advancing China?s Smart Grid: Phasor Measurement Units in a Wide-Area Management System , 2015, IEEE Power and Energy Magazine.

[17]  A.G. Phadke,et al.  Power system frequency monitoring network (FNET) implementation , 2005, IEEE Transactions on Power Systems.

[18]  Yong Liu,et al.  Wide-area measurement system development at the distribution level: An FNET/GridEye example , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[19]  James S. Thorp,et al.  Synchronized Phasor Measurement Applications in Power Systems , 2010, IEEE Transactions on Smart Grid.

[20]  Yilu Liu,et al.  Observation of inertial frequency response of main power grids worldwide using FNET/GridEye , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[21]  J. Thorp,et al.  A New Measurement Technique for Tracking Voltage Phasors, Local System Frequency, and Rate of Change of Frequency , 1983, IEEE Transactions on Power Apparatus and Systems.

[22]  Tao Xia,et al.  Wide-area Frequency Based Event Location Estimation , 2007, 2007 IEEE Power Engineering Society General Meeting.

[23]  Li He,et al.  Highly accurate frequency estimation for FNET , 2013, 2013 IEEE Power & Energy Society General Meeting.

[24]  Yilu Liu,et al.  Analysis of societal event impacts on the power system frequency using FNET measurements , 2011, 2011 IEEE Power and Energy Society General Meeting.

[25]  Yun Zhu,et al.  Research on power dispatching automation system based on cloud computing , 2012, IEEE PES Innovative Smart Grid Technologies.

[26]  K. Uhlen,et al.  Wide Area Monitoring Experiences in Norway , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[27]  L. Zhan,et al.  Improved WLS-TF algorithm for dynamic synchronized angle and frequency estimation , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[28]  Yilu Liu,et al.  Oscillation analysis in Western Interconnection using distribution-level phasor measurements , 2011, 2011 IEEE Power and Energy Society General Meeting.

[29]  Yilu Liu,et al.  Analysis of frequency extrema in the eastern and western interconnections , 2011, 2011 IEEE Power and Energy Society General Meeting.

[30]  Yilu Liu,et al.  Impact of Governor Deadband on Frequency Response of the U.S. Eastern Interconnection , 2016, IEEE Transactions on Smart Grid.

[31]  Herwig Renner,et al.  Opportunities to exploit Phasor Measurement Units (PMUs) and synchrophasor measurements on the GB Transmission Network , 2012 .

[32]  P. Bonanomi Phase Angle Measurements with Synchronized Clocks-Principle and Applications , 1981, IEEE Transactions on Power Apparatus and Systems.