Time Delay Estimation in Reverberant Environment Based on Acoustic Pyrometry
暂无分享,去创建一个
The acoustic thermometry has many advantages, compared with conventional methods of temperature measurements. For this technology, the sound field in normal temperature state of the boiler was simulated; acoustic source signal obtained the pseudo random sequence signal and time delay estimation selected the weighted cross-correlation method. Experiments show that when the boiler is not running, the sound field is enclosure sound field in the furnace. The weighted cross-correlation method can restrain the reverberation and obtain the accurate time delay estimation.
[1] Naim Afgan,et al. Concept of expert system for boiler fouling assessment , 1996 .
[2] Shuhei Takahashi,et al. Acoustic computer tomographic pyrometry for two-dimensional measurement of gases taking into account the effect of refraction of sound wave paths , 2000 .
[3] William Norris,et al. THE MEASUREMENT OF PERFORMANCE OF COMBUSTORS USING PASSIVE ACOUSTIC METHODS , 2004 .