Accuracy of Dipole Localization with a Spherical Homogeneous Model

Dipole localization methods (DLM's) with a spherical, homogeneous, isotropic model were applied to the problem of locating and characterizing simulated dipole sources of the brainstem acoustic evoked response (BAER) in cats. Dipole source parameters considered were chosen to be consistent with measurements of gross potential within the brainstem during the BAER. The steepest ascent method was used to solve the least-squares minimization problem on a set of noiseperturbed surface voltages to obtain parameters of a single assumed dipole source. The magnitudes of errors in dipole postion and in dipole moment vectors were calculated for two surface voltage location sets, two assumed dipole source locations, and a range of surface signal-to-noise ratios. An approximate analytic approach to the simulation results attributed DLM errors to an apparent "noise dipole" calculated as the dipole term in the multipole expansion of the added surface noise. The standard deviation of the "noise dipole" magnitude was directly proportional to the standard deviation of surface noise voltage and inversely proportional to the root of the number of surface voltages. This analytic result was in general agreement with the mean of the dipole moment parameter errors in the simulation study. It was found that recalculation of the surface voltage set from the solution dipole of the simulation problem or from the "noise dipole" of the analytic treatment resulted in an improvement of signal-to-noise ratio at the surface.

[1]  D L Jewett,et al.  The effect of media inhomogeneities upon intracranial electrical fields. , 1972, IEEE transactions on bio-medical engineering.

[2]  R C Barr,et al.  Automated production of contour maps for electrophysiology. III. Construction of contour maps. , 1980, Computers and biomedical research, an international journal.

[3]  J. P. Ary,et al.  Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses , 1981, IEEE Transactions on Biomedical Engineering.

[4]  F. N. Wilson,et al.  The Electric Field of an Eccentric Dipole in a Homogeneous Spherical Conducting Medium , 1950, Circulation.

[5]  A. Starr,et al.  Auditory brain stem responses in neurological disease. , 1975, Archives of neurology.

[6]  J. Buchwald,et al.  Far-field acoustic response: origins in the cat. , 1975, Science.

[7]  M R Schneider,et al.  A multistage process for computing virtual dipolar sources of EEG discharges from surface information. , 1972, IEEE transactions on bio-medical engineering.

[8]  D L Jewett,et al.  Volume-conducted potentials in response to auditory stimuli as detected by averaging in the cat. , 1970, Electroencephalography and clinical neurophysiology.

[9]  D. B. Geselowitz,et al.  Multipole Representation for an Equivalent Cardiac Generator , 1960, Proceedings of the IRE.

[10]  R C Barr,et al.  Automated production of contour maps for electrophysiology. I. Problem definition, solution strategy, and specification of geometric model. , 1980, Computers and biomedical research, an international journal.

[11]  M. C. Vivion Clinical status of evoked response audiometry , 1980, The Laryngoscope.

[12]  C. V. Nelson,et al.  Determination of the Resultant Dipole of the Heart from Measurements on the Body Surface , 1954 .

[13]  A. Starr,et al.  Auditory brain stem responses in the cat. I. Intracranial and extracranial recordings. , 1980, Electroencephalography and clinical neurophysiology.

[14]  Dietrich Lehmann,et al.  Evaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human Brain , 1978, IEEE Transactions on Biomedical Engineering.