How does distortion correction correlate with anisotropic indices? A diffusion tensor imaging study.

PURPOSE The purpose of this study was to determine a suitable registration algorithm for diffusion tensor imaging (DTI) using conventional preprocessing tools [statistical parametric mapping (SPM) and automated image registration (AIR)] and to investigate how anisotropic indices for clinical assessments are affected by these distortion corrections. MATERIALS AND METHODS Brain DTI data from 15 normal healthy volunteers were used to evaluate four spatial registration schemes within subjects to correct image distortions: noncorrection, SPM-based affine registration, AIR-based affine registration and AIR-based nonlinear polynomial warping. The performance of each distortion correction was assessed using: (a) quantitative parameters: tensor-fitting error (Ef), mean dispersion index (MDI), mean fractional anisotropy (MFA) and mean variance (MV) within 11 regions of interest (ROI) defined from homogeneous fiber bundles; and (b) fiber tractography through the uncinate fasciculus and the corpus callosum. Fractional anisotropy (FA) and mean diffusivity (MD) were calculated to demonstrate the effects of distortion correction. Repeated-measures analysis of variance was used to investigate differences among the four registration paradigms. RESULTS AIR-based nonlinear registration showed the best performance for reducing image distortions with respect to smaller Ef (P<.02), MDI (P<.01) and MV (P<.01) with larger MFA (P<.01). FA was decreased to correct distortions (P<.0001) whether the applied registration was linear or nonlinear and was lowest after nonlinear correction (P<.001). No significant differences were found in MD. CONCLUSION In conventional DTI processing, anisotropic indices of FA can be misestimated by noncorrection or inappropriate distortion correction, which leads to an erroneous increase in FA. AIR-based nonlinear distortion correction would be required for a more accurate measurement of this diffusion parameter.

[1]  Shielded gradients. And the general solution to the near field problem of electromagnet design , 1999, Magnetic Resonance Materials in Physics, Biology and Medicine.

[2]  O. Simonetti,et al.  Theoretical aspects of motion sensitivity and compensation in echo‐planar imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[3]  C. Tempelmann,et al.  Eddy current correction in diffusion‐weighted imaging using pairs of images acquired with opposite diffusion gradient polarity , 2004, Magnetic resonance in medicine.

[4]  M E Bastin,et al.  On the use of water phantom images to calibrate and correct eddy current induced artefacts in MR diffusion tensor imaging. , 2000, Magnetic resonance imaging.

[5]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.

[6]  Carl-Fredrik Westin,et al.  Spatial normalization of diffusion tensor MRI using multiple channels , 2003, NeuroImage.

[7]  S C Williams,et al.  Non‐invasive assessment of axonal fiber connectivity in the human brain via diffusion tensor MRI , 1999, Magnetic resonance in medicine.

[8]  M Cercignani,et al.  Diffusion tensor magnetic resonance imaging in multiple sclerosis , 2001, Neurology.

[9]  M. Kraut,et al.  Comparison of weakness progression in inclusion body myositis during treatment with methotrexate or placebo , 2002, Annals of neurology.

[10]  P. Basser,et al.  Comprehensive approach for correction of motion and distortion in diffusion‐weighted MRI , 2004, Magnetic resonance in medicine.

[11]  I. Wilkinson,et al.  Study of the effect of CSF suppression on white matter diffusion anisotropy mapping of healthy human brain , 2002, Magnetic resonance in medicine.

[12]  Paul Suetens,et al.  Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information , 1999, Medical Image Anal..

[13]  D G Gadian,et al.  Correction for eddy current induced Bo shifts in diffusion‐weighted echo‐planar imaging , 1999, Magnetic resonance in medicine.

[14]  P. Basser,et al.  Estimation of the effective self-diffusion tensor from the NMR spin echo. , 1994, Journal of magnetic resonance. Series B.

[15]  P. Basser,et al.  Diffusion tensor MR imaging of the human brain. , 1996, Radiology.

[16]  Stefan Skare,et al.  A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPI , 2002, NeuroImage.

[17]  P. Basser,et al.  Toward a quantitative assessment of diffusion anisotropy , 1996, Magnetic resonance in medicine.

[18]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[19]  Osamu Abe,et al.  Topography of the Human Corpus Callosum Using Diffusion Tensor Tractography , 2004, Journal of computer assisted tomography.

[20]  P. V. van Zijl,et al.  Three‐dimensional tracking of axonal projections in the brain by magnetic resonance imaging , 1999, Annals of neurology.

[21]  S. Skare,et al.  On the effects of gating in diffusion imaging of the brain using single shot EPI. , 2001, Magnetic resonance imaging.

[22]  Scott T. Grafton,et al.  Automated image registration: I. General methods and intrasubject, intramodality validation. , 1998, Journal of computer assisted tomography.

[23]  J. Foong,et al.  Neuropathological abnormalities of the corpus callosum in schizophrenia: a diffusion tensor imaging study , 2000, Journal of neurology, neurosurgery, and psychiatry.

[24]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[25]  P. Basser,et al.  Statistical artifacts in diffusion tensor MRI (DT‐MRI) caused by background noise , 2000, Magnetic resonance in medicine.

[26]  J C Gore,et al.  Analysis and correction of motion artifacts in diffusion weighted imaging , 1994, Magnetic resonance in medicine.

[27]  P. Basser,et al.  A simplified method to measure the diffusion tensor from seven MR images , 1998, Magnetic resonance in medicine.

[28]  J. Pekar,et al.  Echo-planar imaging of intravoxel incoherent motion. , 1990, Radiology.

[29]  Iain D Wilkinson,et al.  A measure of curve fitting error for noise filtering diffusion tensor MRI data. , 2003, Journal of magnetic resonance.

[30]  P. Basser Inferring microstructural features and the physiological state of tissues from diffusion‐weighted images , 1995, NMR in biomedicine.

[31]  R. Stollberger,et al.  Improved diffusion‐weighted single‐shot echo‐planar imaging (EPI) in stroke using sensitivity encoding (SENSE) , 2001, Magnetic resonance in medicine.

[32]  L. M. Auer,et al.  Fiber Tracking from DTI Using Linear State Space Models: Detectability of the Pyramidal Tract , 2002, NeuroImage.

[33]  M S Buchsbaum,et al.  Regional and global changes in cerebral diffusion with normal aging. , 2001, AJNR. American journal of neuroradiology.

[34]  H S Markus,et al.  Characterization of white matter damage in ischemic leukoaraiosis with diffusion tensor MRI. , 1999, Stroke.