Weaning Preterm Infants from Mechanical Ventilation

Mechanical ventilatory support is required by a large number of neonates in respiratory failure. However, its use in preterm infants is frequently associated with acute complications and long-term respiratory sequelae. Therefore, it is recommended to avoid or limit the exposure to ventilatory support. This is a review of existing practices and novel strategies to achieve weaning of ventilatory support in this population.

[1]  W. Carlo,et al.  Outcome of Extremely Preterm Infants Randomized at Birth to Different PaCO2 Targets during the First Seven Days of Life , 2006, Neonatology.

[2]  E. Bancalari,et al.  Effects of volume-guaranteed synchronized intermittent mandatory ventilation in preterm infants recovering from respiratory failure. , 2002, Pediatrics.

[3]  C. Romagnoli,et al.  Spontaneous minute ventilation is a predictor of extubation failure in extremely-low-birth-weight infants , 2004, The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians.

[4]  E. Bancalari,et al.  Randomized, Controlled Trial Comparing Synchronized Intermittent Mandatory Ventilation and Synchronized Intermittent Mandatory Ventilation Plus Pressure Support in Preterm Infants , 2006, Pediatrics.

[5]  Christopher H Schmid,et al.  Achieved Versus Intended Pulse Oximeter Saturation in Infants Born Less Than 28 Weeks' Gestation: The AVIOx Study , 2006, Pediatrics.

[6]  W. Poole,et al.  Minimal ventilation to prevent bronchopulmonary dysplasia in extremely-low-birth-weight infants. , 2002, The Journal of pediatrics.

[7]  Jennifer Dawson,et al.  Compliance With Alarm Limits for Pulse Oximetry in Very Preterm Infants , 2007, Pediatrics.

[8]  Francesc Botet,et al.  Changes in TcPCO 2 regarding pulmonary mechanics due to pneumotachometer dead space in ventilated newborns , 1997, Journal of perinatal medicine.

[9]  A. Greenough Update on patient-triggered ventilation. , 2001, Clinics in perinatology.

[10]  R. G. Cameron,et al.  Closed-loop control of the partial pressure of arterial oxygen in neonates. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[11]  P. Clarke,et al.  Mechanical ventilation of very low birth weight infants: is volume or pressure a better target variable? , 2006, The Journal of pediatrics.

[12]  S. Godfrey,et al.  New technique for servo-control of arterial oxygen tension in preterm infants. , 1979, Archives of disease in childhood.

[13]  W. Carlo,et al.  Randomized Trial of Permissive Hypercapnia in Preterm Infants: A Pilot Study. • 962 , 1997, Pediatric Research.

[14]  A. Greenough,et al.  Comparison of weaning by patient triggered ventilation or synchronous intermittent mandatory ventilation in preterm infants , 1994, Acta paediatrica.

[15]  B. Lemyre,et al.  Nasal continuous positive airway pressure versus nasal intermittent positive pressure ventilation for preterm neonates: a systematic review and meta‐analysis , 2003, Acta paediatrica.

[16]  E. Bancalari,et al.  Elimination of ventilator dead space during synchronized ventilation in premature infants. , 2003, Jornal de Pediatria.

[17]  E. H. Kim,et al.  Successful direct extubation of very low birth weight infants from low intermittent mandatory ventilation rate. , 1987, Pediatrics.

[18]  J. Fisher,et al.  The effects of bedside pulmonary mechanics testing during infant mechanical ventilation: A retrospective analysis , 1993, Pediatric pulmonology.

[19]  Silvia Miksch,et al.  Automatic control of the inspired oxygen fraction in preterm infants: a randomized crossover trial. , 2004, American journal of respiratory and critical care medicine.

[20]  P. Davis,et al.  Prophylactic methylxanthines for extubation in preterm infants. , 2003, The Cochrane database of systematic reviews.

[21]  C. O. Kamlin,et al.  Predicting successful extubation of very low birthweight infants , 2005, Archives of Disease in Childhood - Fetal and Neonatal Edition.

[22]  S. Donn,et al.  Usefulness of the Minute Ventilation Test in Predicting Successful Extubation in Newborn Infants: A Randomized Controlled Trial , 2003, Journal of Perinatology.

[23]  L. Brochard,et al.  Efficacy of dead-space washout in mechanically ventilated premature newborns. , 1996, American journal of respiratory and critical care medicine.

[24]  E. Bancalari,et al.  Computer-controlled minute ventilation in preterm infants undergoing mechanical ventilation. , 1997, The Journal of pediatrics.

[25]  S. Donn,et al.  Randomised trial of volume controlled versus time cycled, pressure limited ventilation in preterm infants with respiratory distress syndrome , 1997, Archives of disease in childhood. Fetal and neonatal edition.

[26]  P. Davis,et al.  Nasal continuous positive airway pressure immediately after extubation for preventing morbidity in preterm infants , 2003 .

[27]  E. Bancalari,et al.  Targeted Minute Ventilation and Tidal Volume in an Animal Model of Acute Changes in Lung Mechanics and Episodes of Hypoxemia , 2008, Neonatology.

[28]  L. Brochard,et al.  Continuous tracheal gas insufflation in preterm infants with hyaline membrane disease. A prospective randomized trial. , 2000, American journal of respiratory and critical care medicine.

[29]  J. Fisher,et al.  Identifying lung overdistention during mechanical ventilation by using volume‐pressure loops , 1988, Pediatric pulmonology.

[30]  E. Bancalari,et al.  Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia. , 2001, Pediatrics.

[31]  A. Numa,et al.  Anatomic dead space in infants and children. , 1996, Journal of applied physiology.

[32]  A. Fanaroff,et al.  Efficacy of computer-assisted management of respiratory failure in neonates. , 1986, Pediatrics.

[33]  S. Donn,et al.  A Crossover Analysis of Mandatory Minute Ventilation Compared to Synchronized Intermittent Mandatory Ventilation in Neonates , 2005, Journal of Perinatology.