Detection of Clenbuterol Hydrochloride Residuals in Pork Liver Using a Customized Surface Plasmon Resonance Bioanalyzer

A surface plasmon resonance (SPR) immunoassay with an immobilization of self-assembled molecular identification membrane for the detection of residual Clenbuterol Hydrochloride (CLB) in pork liver was systematically investigated and experimentally validated for its high performance. SPR immunoassay with a regular competitive inhibition assay cannot be directly verified to detect CLB residuals. In this study, the binding of Au film with mercaptopropionic acid was investigated using the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. After that, the immunoglobulin IgG of swine (SwIgG-CLB) was bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. The modified comprehensive analysis of how the membrane structure works was introduced together with the customized SPR bioanalyzer. In order to evaluate the performance of this biomembrane structure, the concentrations of CLB-contained solutions of 0 ng•mL-1, 10 ng•mL-1, 20 ng•mL-1, 33.3 ng•mL-1, and 40 ng•mL-1 were prepared by adding CLB reagents into the solutions of CLB antibody (Clenbuterol Hydrochloride Antibody, CLB-Ab), successively and then the response unit (RU) was measured individually. Using the data collected from the linear CCD array, the fitting curve was established with the R-Square value of 0.9929. Correspondingly, the recovery rate ranged from 88.48% to 103.21% was experimented and the limit of detection of CLB in 1.26 ng•mL-1 was obtained efficiently. It was concluded that the detection method associated with biomembrane properties is expected to contribute much to the determination of residual CLB in pork liver quantitatively by using the customized SPR bioanalyzer.

[1]  Jingang Zhong,et al.  Quick detection technique for clenbuterol hydrochloride by using surface plasmon resonance biosensor , 2014, European Food Research and Technology.

[2]  Xin Yang,et al.  An electrochemical immunosensor for rapid determination of clenbuterol by using magnetic nanocomposites to modify screen printed carbon electrode based on competitive immunoassay mode , 2014 .

[3]  Panpan Yan,et al.  Ultrasensitive detection of clenbuterol by quantum dots based electrochemiluminescent immunosensor using gold nanoparticles as substrate and electron transport accelerator , 2014 .

[4]  P. Charette,et al.  Identification of the molecular mechanisms in cellular processes that elicit a surface plasmon resonance (SPR) response using simultaneous surface plasmon-enhanced fluorescence (SPEF) microscopy. , 2013, Biosensors & bioelectronics.

[5]  N. Baume,et al.  Quantification of clenbuterol at trace level in human urine by ultra-high pressure liquid chromatography-tandem mass spectrometry. , 2013, Journal of chromatography. A.

[6]  Feng-xia Qiao,et al.  Rapid screening of clenbuterol hydrochloride in chicken samples by molecularly imprinted matrix solid-phase dispersion coupled with liquid chromatography. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[7]  G. Favero,et al.  Comparison of three immunosensor methods (surface plasmon resonance, screen-printed and classical amperometric immunosensors) for immunoglobulin G determination in human serum and animal or powdered milks. , 2013, Journal of pharmaceutical and biomedical analysis.

[8]  Can Wu,et al.  Electrochemical sensor for toxic ractopamine and clenbuterol based on the enhancement effect of graphene oxide , 2012 .

[9]  T. Wei,et al.  Surface Plasmon Resonance Sensor for Supersensitive Detection of Clenbuterol Using Molecularly Imprinted Film , 2012 .

[10]  Xiao Lu,et al.  Detection of ractopamine residues in pork by surface plasmon resonance-based biosensor inhibition immunoassay , 2012 .

[11]  Jiandong Hu,et al.  Development of a label-free and innovative approach based on surface plasmon resonance biosensor for on-site detection of infectious bursal disease virus (IBDV). , 2012, Biosensors & bioelectronics.

[12]  G. Jin,et al.  Preparation of molecular imprinted film based on chitosan/nafion/nano-silver/poly quercetin for clenbuterol sensing. , 2011, Food chemistry.

[13]  J. Ruiz,et al.  Development of a panel of highly sensitive, equivalent assays for detection of antibody responses to velaglucerase alfa or imiglucerase enzyme replacement therapy in patients with Gaucher disease. , 2011, Journal of immunological methods.

[14]  Chunhai Fan,et al.  A carbon nanotube-based high-sensitivity electrochemical immunosensor for rapid and portable detection of clenbuterol. , 2011, Biosensors & bioelectronics.

[15]  Christopher T. Elliott,et al.  Advances in surface plasmon resonance biosensor technology towards high-throughput food safety analysis , 2010 .

[16]  Jelka Pleadin,et al.  Clenbuterol residues in pig muscle after repeat administration in a growth-promoting dose. , 2010, Meat science.

[17]  Wei Li,et al.  Design and validation of a low cost surface plasmon resonance bioanalyzer using microprocessors and a touch-screen monitor. , 2009, Biosensors & bioelectronics.

[18]  Wenjun Yang,et al.  Development of a label-free electrochemical immunosensor based on carbon nanotube for rapid determination of clenbuterol , 2009 .

[19]  N. Miura,et al.  Recent advancements in surface plasmon resonance immunosensors for detection of small molecules of biomedical, food and environmental interest , 2007 .

[20]  Yahong Liu,et al.  Determination of ractopamine and clenbuterol in feeds by gas chromatography–mass spectrometry , 2007 .

[21]  D. Zhao,et al.  Development of an immunochromatographic lateral flow test strip for detection of beta-adrenergic agonist Clenbuterol residues. , 2006, Journal of immunological methods.

[22]  Jun Kondoh,et al.  Development of novel optical waveguide surface plasmon resonance (SPR) sensor with dual light emitting diodes , 2005 .

[23]  Christopher T. Elliott,et al.  Detection of multi-β-agonist residues in liver matrix by use of a surface plasma resonance biosensor , 2003 .

[24]  P. Kościelniak,et al.  Examination of interferences in flame atomic absorption spectrometry using a flow injection technique , 2001 .