Diffuse reflectance spectroscopy: towards clinical application in breast cancer

Diffuse reflectance spectroscopy (DRS) is a promising new technique for breast cancer diagnosis. However, inter-patient variation due to breast tissue heterogeneity may interfere with the accuracy of this technique. To tackle this issue, we aim to determine the diagnostic accuracy of DRS in individual patients. With this approach, DRS measurements of normal breast tissue in every individual patient are directly compared with measurements of the suspected malignant tissue. Breast tissue from 47 female patients was analysed ex vivo by DRS. A total of 1,073 optical spectra were collected. These spectra were analyzed for each patient individually as well as for all patients collectively and results were compared to the pathology analyses. Collective patient data analysis for discrimination between normal and malignant breast tissue resulted in a sensitivity of 90 %, a specificity of 88 %, and an overall accuracy of 89 %. In the individual analyses all measurements per patient were categorized as either benign or malignant. The discriminative accuracy of these individual analyses was nearly 100 %. The diagnosis was classified as uncertain in only one patient. Based on the results presented in this study, we conclude that the analysis of optical characteristics of different tissue classes within the breast of a single patient is superior to an analysis using the results of a cohort data analysis. When integrated into a biopsy device, our results demonstrate that DRS may have the potential to improve the diagnostic workflow in breast cancer.

[1]  Nimmi Ramanujam,et al.  Optical breast cancer margin assessment: an observational study of the effects of tissue heterogeneity on optical contrast , 2010, Breast Cancer Research.

[2]  Rami Nachabé,et al.  Effect of bile absorption coefficients on the estimation of liver tissue optical properties and related implications in discriminating healthy and tumorous samples , 2011, Biomedical optics express.

[3]  Alessandro Torricelli,et al.  Absorption of collagen: effects on the estimate of breast composition and related diagnostic implications. , 2007, Journal of biomedical optics.

[4]  P. Thorner,et al.  Effectiveness of fine‐needle aspiration cytology of breast: Analysis of 2,375 cases from northern Thailand , 2002, Diagnostic cytopathology.

[5]  Anita Mahadevan-Jansen,et al.  Comparison of autofluorescence, diffuse reflectance, and Raman spectroscopy for breast tissue discrimination. , 2008, Journal of biomedical optics.

[6]  Nirmala Ramanujam,et al.  Quantitative optical spectroscopy: a robust tool for direct measurement of breast cancer vascular oxygenation and total hemoglobin content in vivo. , 2009, Cancer research.

[7]  Zoya I. Volynskaya,et al.  Diagnosing breast cancer using diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy. , 2008, Journal of biomedical optics.

[8]  Nirmala Ramanujam,et al.  Autofluorescence and diffuse reflectance properties of malignant and benign breast tissues , 2004, Annals of Surgical Oncology.

[9]  Nirmala Ramanujam,et al.  Diagnosis of breast cancer using fluorescence and diffuse reflectance spectroscopy: a Monte-Carlo-model-based approach. , 2008, Journal of biomedical optics.

[10]  Zoya I. Volynskaya,et al.  A multimodal spectroscopy system for real-time disease diagnosis. , 2009, The Review of scientific instruments.

[11]  Paola Taroni,et al.  Diffuse optical spectroscopy of breast tissue extended to 1100 nm. , 2009, Journal of biomedical optics.

[12]  G. Zonios,et al.  Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo. , 1999, Applied optics.

[13]  W. Kruskal,et al.  Use of Ranks in One-Criterion Variance Analysis , 1952 .

[14]  Anita Mahadevan-Jansen,et al.  Autofluorescence and diffuse reflectance spectroscopy and spectral imaging for breast surgical margin analysis , 2010, Lasers in surgery and medicine.

[15]  Karthik Vishwanath,et al.  Advances in quantitative UV-visible spectroscopy for clinical and pre-clinical application in cancer. , 2009, Current opinion in biotechnology.

[16]  T. Stephens Missed Breast Cancers at US-guided Core Needle Biopsy: How to Reduce Them , 2011 .

[17]  K. Bloom,et al.  Fine-needle aspiration of clinically suspicious palpable breast masses with histopathologic correlation. , 2002, American journal of surgery.

[18]  Leo Breiman,et al.  Classification and Regression Trees , 1984 .

[19]  Rami Nachabé,et al.  Estimation of biological chromophores using diffuse optical spectroscopy: benefit of extending the UV-VIS wavelength range to include 1000 to 1600 nm , 2010, Biomedical optics express.

[20]  S. Roe,et al.  Stereotactic Core-Needle Breast Biopsy by Surgeons: Minimum 2-Year Follow-Up of Benign Lesions , 2000, Annals of surgery.

[21]  B. Wilson,et al.  A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. , 1992, Medical physics.

[22]  Rami Nachabé,et al.  Diagnosis of breast cancer using diffuse optical spectroscopy from 500 to 1600 nm: comparison of classification methods. , 2011, Journal of biomedical optics.

[23]  J. Frangioni,et al.  Image-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation , 2010, Molecular imaging.

[24]  Nirmala Ramanujam,et al.  Model based and empirical spectral analysis for the diagnosis of breast cancer. , 2008, Optics express.

[25]  Nirmala Ramanujam,et al.  Diagnosis of breast cancer using diffuse reflectance spectroscopy: Comparison of a Monte Carlo versus partial least squares analysis based feature extraction technique , 2006, Lasers in surgery and medicine.

[26]  M. B. van der Mark,et al.  Estimation of lipid and water concentrations in scattering media with diffuse optical spectroscopy from 900 to 1,600 nm. , 2010, Journal of biomedical optics.

[27]  Venkataramanan Krishnaswamy,et al.  Automated classification of breast pathology using local measures of broadband reflectance. , 2010, Journal of biomedical optics.

[28]  Karthik Vishwanath,et al.  Using optical spectroscopy to longitudinally monitor physiological changes within solid tumors. , 2009, Neoplasia.

[29]  Alexander L. Vahrmeijer,et al.  Optical Image-guided Surgery—Where Do We Stand? , 2010, Molecular Imaging and Biology.

[30]  Alessandro Torricelli,et al.  Noninvasive assessment of breast cancer risk using time-resolved diffuse optical spectroscopy. , 2010, Journal of biomedical optics.

[31]  S. Lakhani,et al.  Diagnosis of breast cancer using elastic-scattering spectroscopy: preliminary clinical results. , 2000, Journal of biomedical optics.