A dynamical model for generating synthetic electrocardiogram signals

A dynamical model based on three coupled ordinary differential equations is introduced which is capable of generating realistic synthetic electrocardiogram (ECG) signals. The operator can specify the mean and standard deviation of the heart rate, the morphology of the PQRST cycle, and the power spectrum of the RR tachogram. In particular, both respiratory sinus arrhythmia at the high frequencies (HFs) and Mayer waves at the low frequencies (LFs) together with the LF/HF ratio are incorporated in the model. Much of the beat-to-beat variation in morphology and timing of the human ECG, including QT dispersion and R-peak amplitude modulation are shown to result. This model may be employed to assess biomedical signal processing techniques which are used to compute clinical statistics from the ECG.

[1]  Patrick E. McSharry,et al.  Better Nonlinear Models from Noisy Data: Attractors with Maximum Likelihood , 1999, chao-dyn/9912002.

[2]  William H. Press,et al.  Numerical recipes in C , 2002 .

[3]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[4]  A. Goldberger Clinical Electrocardiography: A Simplified Approach , 1977 .

[5]  William H. Press,et al.  Numerical Recipes in C, 2nd Edition , 1992 .

[6]  J. Alpert,et al.  ACC/AHA Guidelines for Ambulatory Electrocardiography. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Revise the Guidelines for Ambulatory Electrocardiography). Developed in collaboration with the North American Society for P , 1999, Journal of the American College of Cardiology.

[7]  G. Breithardt,et al.  Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. , 1996 .

[8]  D. T. Kaplan Simultaneous QRS detection and feature extraction using simple matched filter basis functions , 1990, [1990] Proceedings Computers in Cardiology.

[9]  J Strackee,et al.  Hemodynamic fluctuations and baroreflex sensitivity in humans: a beat-to-beat model. , 1987, The American journal of physiology.

[10]  P. Davey,et al.  A new physiological method for heart rate correction of the QT interval , 1999, Heart.

[11]  J. Alpert,et al.  ACC/AHA guidelines for ambulatory electrocardiography: executive summary and recommendations. A report of the American College of Cardiology/American Heart Association task force on practice guidelines (committee to revise the guidelines for ambulatory electrocardiography). , 1999, Circulation.

[12]  M Malik Heart rate variability. , 1998, Current opinion in cardiology.

[13]  P. Schwartz,et al.  QT interval prolongation as predictor of sudden death in patients with myocardial infarction. , 1978, Circulation.

[14]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[15]  G. Moody,et al.  Power spectral density of unevenly sampled data by least-square analysis: performance and application to heart rate signals , 1998, IEEE Transactions on Biomedical Engineering.