High-frame rate, full-view myocardial elastography with automated contour tracking in murine left ventricles in vivo

Myocardial elastography is a novel method for noninvasively assessing regional myocardial function, with the advantages of high resolution and high precision. The purpose in this paper was to isolate the left ventricle from other structures for better displacement and strain visualization. Using a high-resolution (30 MHz) ultrasound system and a retrospective electrocardiogram (ECG)-gating technique, an extremely high frame rate (up to 8 kHz) was previously shown achievable for full-view (12-mm times 12-mm) myocardial elastography in the murine left ventricle. In vivo experiments were performed in anesthetized normal and infarcted mice [one day after left anterior descending (LAD) coronary artery ligation]. Radio frequency (RF) signals of the left ventricle (LV) in the long-axis view and the associated ECG were simultaneously acquired, with the ECG allowing gating of the RF signals. Incremental axial displacement of the myocardium was estimated using a one-dimensional (1-D) cross-correlation function. The cumulative displacement and strain then were calculated from the incremental displacement. In this paper, after manual selection of 40-50 points along the endo-and epicardial borders in the first frame of the cine-loop, myocardial contour was automatically tracked across the entire LV throughout a full cardiac cycle, which correctly determined the region of interest (ROI) for better interpretation. The cine-loop of the cumulative displacement and strain in one cardiac cycle, in both the normal and infarcted cases, showed that motion and deformation in the infarcted myocardium were significantly reduced, and that the infarcted region underwent thinning, rather than thickening, during systole. High precision of the displacement estimation, due to high frequency (30 MHz) and high frame rate (up to 8 kHz) available with this system, allowed for automated tracking of a manually-initialized myocardial contour over an entire cardiac cycle. High frame rate, full-view myocardial elastography with automated contour tracking could provide regional strain information of the LV throughout an entire cardiac cycle, and characterize normal as well as detect abnormal myocardial function, such as an infarction. The method of automated contour tracking can further enhance the capability of the elastographic technique with minimal user intervention while providing accurate functional information for the detection of disease throughout the entire cardiac cycle.

[1]  Thomas J. Ryan,et al.  Feigenbaum's echocardiography , 1972 .

[2]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[3]  G R Sutherland,et al.  Colour Doppler velocity imaging of the myocardium. , 1992, Ultrasound in medicine & biology.

[4]  J. Lazar,et al.  Comparison of left ventricular function by echocardiographic automated border detection and by radionuclide ejection fraction. , 1993, The American journal of cardiology.

[5]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  M. Bilgen,et al.  Error analysis in acoustic elastography. I. Displacement estimation. , 1997, The Journal of the Acoustical Society of America.

[7]  T Akasaka,et al.  Echocardiographic estimation of left ventricular cavity area with a newly developed automated contour tracking method. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[8]  J. Ophir,et al.  Three-dimensional tissue motion and its effect on image noise in elastography , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  N. Chubachi,et al.  Noninvasive evaluation of local myocardial thickening and its color-coded imaging , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  James D. Thomas,et al.  Segmentation and tracking in echocardiographic sequences: active contours guided by optical flow estimates , 1998, IEEE Transactions on Medical Imaging.

[11]  A. Støylen,et al.  Real-time strain rate imaging of the left ventricle by ultrasound. , 1998, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[12]  J. Soraghan,et al.  Automatic cardiac LV boundary detection and tracking using hybrid fuzzy temporal and fuzzy multiscale edge detection , 1999, IEEE Transactions on Biomedical Engineering.

[13]  J Ophir,et al.  Precision estimation and imaging of normal and shear components of the 3D strain tensor in elastography. , 2000, Physics in medicine and biology.

[14]  M. Kern,et al.  Effect of intravenous contrast for left ventricular opacification and border definition on sensitivity and specificity of dobutamine stress echocardiography compared with coronary angiography in technically difficult patients. , 2001, American heart journal.

[15]  M. O’Donnell,et al.  Strain rate imaging using two-dimensional speckle tracking , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  P. Suetens,et al.  Evaluation of transmural myocardial deformation and reflectivity characteristics , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[17]  J. Ophir,et al.  Myocardial elastography--a feasibility study in vivo. , 2002, Ultrasound in medicine & biology.

[18]  Paul Suetens,et al.  Two-dimensional ultrasonic strain rate measurement of the human heart in vivo , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  Paul Suetens,et al.  Echocardiographic strain and strain-rate imaging: a new tool to study regional myocardial function , 2002, IEEE Transactions on Medical Imaging.

[20]  W. Walker,et al.  A comparison of the performance of time-delay estimators in medical ultrasound , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  N. Paragios,et al.  A level set approach for shape-driven segmentation and tracking of the left ventricle , 2003, IEEE Transactions on Medical Imaging.

[22]  P. Lysyansky,et al.  Global longitudinal strain: a novel index of left ventricular systolic function. , 2004, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[23]  Qing Nie,et al.  Mouse cardiac surgery: comprehensive techniques for the generation of mouse models of human diseases and their application for genomic studies. , 2004, Physiological genomics.

[24]  Jing Bai,et al.  Axial strain calculation using a low-pass digital differentiator in ultrasound elastography , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  High resolution quantification of myocardial motion in mice using 2d speckle tracking , 2005, IEEE Ultrasonics Symposium, 2005..

[26]  E. Konofagou,et al.  Electromechanical imaging of the myocardium at normal and pathological states , 2005, IEEE Ultrasonics Symposium, 2005..

[27]  Elsa D. Angelini,et al.  Tracking of LV Endocardial Surface on Real-Time Three-Dimensional Ultrasound with Optical Flow , 2005, FIMH.

[28]  Paula Finn,et al.  American Heart Association--scientific sessions 2005. 13-16 November 2005, Dallas, TX, USA. , 2006, IDrugs : the investigational drugs journal.

[29]  Andrew Needles,et al.  Ultrahigh frame rate retrospective ultrasound microimaging and blood flow visualization in mice in vivo. , 2006, Ultrasound in medicine & biology.

[30]  2H-2 Gradients in Radial Strain Across the Cardiac Wall Studied with Epicardial Ultrasound , 2006, 2006 IEEE Ultrasonics Symposium.

[31]  Elisa E. Konofagou,et al.  Analysis of 3 D Motion Effects in Myocardial Elastography , 2006 .

[32]  P. Wolf,et al.  Heart disease and stroke statistics--2006 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2006, Circulation.

[33]  2H-3 Imaging of Murine Infarcts Using Myocardial Elastography at Both High Temporal and Spatial Resolution , 2006, 2006 IEEE Ultrasonics Symposium.

[34]  Wei-Ning Lee,et al.  P1A-5 Analysis of 3D Motion Effects in Myocardial Elastography , 2006, 2006 IEEE Ultrasonics Symposium.

[35]  E. Konofagou,et al.  ECG-gated, mechanical and electromechanical wave imaging of cardiovascular tissues in vivo. , 2007, Ultrasound in medicine & biology.

[36]  E. Konofagou,et al.  Myocardial elastography at both high temporal and spatial resolution for the detection of infarcts. , 2007, Ultrasound in medicine & biology.

[37]  Jianwen Luo,et al.  P4A-2 An In-Vivo Study of Frame Rate Optimization for Myocardial Elastography , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.

[38]  E. Konofagou,et al.  Angle-independent and multi-dimensional myocardial elastography--from theory to clinical validation. , 2008, Ultrasonics.

[39]  J. Ophir,et al.  IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[40]  Surya M. Artham Feigenbaum's Echocardiography , 2010 .