Dielectric Frequency Response and temperature dependence of power factor

Modern technology and developments in signal acquisition and analysis techniques have provided new tools for transformer diagnostics. Of particular interest are dielectric response measurements where insulation properties of oil-paper systems can be investigated. Dielectric Frequency Response, DFR (also known as Frequency Domain Spectroscopy, FDS), was introduced more than a decade ago and has been thoroughly evaluated in a number of research projects and field tests with good results. DFR data in combination with mathematical modeling of the oil-paper insulation is proven as an excellent tool for moisture assessment. Since the modeling theory contains influence of temperature, DFR and modeling can be used to calculate the temperature dependence of the insulation system. This paper gives a background to DFR, insulation modeling and how these tools can be utilized to improve understanding of power factor temperature dependence and how this can be used for decisions on maintenance and/or replacement.

[1]  H. G. Sedding,et al.  Accelerated aging and diagnostic testing of 115 kV Type U bushings , 2000, Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075).

[2]  R. B. Blodgett,et al.  Influence of Absorbed Water and Temperature on Tan Delta and Dielectric Constant of Oil-Impregnated Paper Insulation , 1962, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[3]  Stanislaw Gubanski,et al.  Reliable Diagnostics of HV Transfromers Insulation for Safety Assurance of Power Transmission System. REDIATOOL - an European Research Project , 2006 .

[4]  P. Werelius,et al.  Diagnosis of medium voltage XLPE cables by high voltage dielectric spectroscopy , 1998, ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132).

[5]  R. Neimanis,et al.  Determination of moisture content in mass impregnated cable insulation using low frequency dielectric spectroscopy , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[6]  W. S. Zaengl,et al.  Dielectric Response Methods for Diagnostics of Power Transformers , 2003 .

[7]  L. Adeen,et al.  Dielectric spectroscopy in time and frequency domain applied to diagnostics of power transformers , 2000, Proceedings of the 6th International Conference on Properties and Applications of Dielectric Materials (Cat. No.00CH36347).