Identification of Constant-Posture EMG–Torque Relationship About the Elbow Using Nonlinear Dynamic Models

The surface electromyogram (EMG) from biceps and triceps muscles of 33 subjects was related to elbow torque, contrasting EMG amplitude (EMGσ) estimation processors, linear/nonlinear model structures, and system identification techniques. Torque estimation was improved by 1) advanced EMGσ processors (i.e., whitened, multiple-channel signals); 2) longer duration training sets (52 s versus 26 s); and 3) determination of model parameters via pseudoinverse and ridge regression methods. Dynamic, nonlinear parametric models that included second- or third-degree polynomial functions of EMGσ outperformed linear models and Hammerstein/Weiner models. A minimum error of 4.65 ± 3.6% maximum voluntary contraction (MVC) flexion was attained using a third-degree polynomial, 28th-order dynamic model, with model parameters determined using the pseudoinverse method with tolerance 5.6 × 10-3 on 52 s of four-channel whitened EMG data. Similar performance (4.67 ± 3.7% MVC flexion error) was realized using a second-degree, 18th-order ridge regression model with ridge parameter 50.1.

[1]  Arthur F T Mak,et al.  Feasibility of using EMG driven neuromusculoskeletal model for prediction of dynamic movement of the elbow. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[2]  G. Rau,et al.  Surface Electromyography in Relation to Force, Muscle Length and Endurance , 1973 .

[3]  E. Clancy,et al.  Influence of advanced electromyogram (EMG) amplitude processors on EMG-to-torque estimation during constant-posture, force-varying contractions. , 2006, Journal of biomechanics.

[4]  N. Hogan,et al.  Single site electromyograph amplitude estimation , 1994, IEEE Transactions on Biomedical Engineering.

[5]  B Hudgins,et al.  Myoelectric signal processing for control of powered limb prostheses. , 2006, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[6]  N. Hogan,et al.  Multiple site electromyograph amplitude estimation , 1995, IEEE Transactions on Biomedical Engineering.

[7]  M Solomonow,et al.  EMG-force model of the elbows antagonistic muscle pair. The effect of joint position, gravity and recruitment. , 1986, American journal of physical medicine.

[8]  Thomas A. Jones,et al.  Multiple regression with correlated independent variables , 1972 .

[9]  E A Clancy,et al.  Estimation and application of EMG amplitude during dynamic contractions. , 2001, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[10]  William H. Press,et al.  Numerical recipes in C , 2002 .

[11]  D. Richard Brown,et al.  Adaptive whitening in electromyogram amplitude estimation for epoch-based applications , 2005, IEEE Transactions on Biomedical Engineering.

[12]  I. Kingma,et al.  Heterogeneity of muscle activation in relation to force direction: a multi-channel surface electromyography study on the triceps surae muscle. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[13]  Jaap Harlaar,et al.  Accuracy of a practicable EMG to force model for knee muscles , 2004, Neuroscience Letters.

[14]  Edward A. Clancy,et al.  Adaptive whitening of the electromyogram to improve amplitude estimation , 2000, IEEE Transactions on Biomedical Engineering.

[15]  Stephen H M Brown,et al.  Co-activation alters the linear versus non-linear impression of the EMG-torque relationship of trunk muscles. , 2008, Journal of biomechanics.

[16]  David J. Ostry,et al.  A critical evaluation of the force control hypothesis in motor control , 2003, Experimental Brain Research.

[17]  Robert W. Mann,et al.  Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part I: Derivation of the Optimal Myoprocessor , 1980, IEEE Transactions on Biomedical Engineering.

[18]  Stephen H. M. Brown,et al.  Less is more: high pass filtering, to remove up to 99% of the surface EMG signal power, improves EMG-based biceps brachii muscle force estimates. , 2004, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[19]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[20]  J. Harlaar,et al.  A clinically applicable EMG-force model to quantify active stabilization of the knee after a lesion of the anterior cruciate ligament. , 2003, Clinical biomechanics.

[21]  M. O'Malley,et al.  Effect of elbow joint angle on force-EMG relationships in human elbow flexor and extensor muscles. , 2008, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[22]  E.A. Clancy,et al.  Electromyogram amplitude estimation with adaptive smoothing window length , 1999, IEEE Transactions on Biomedical Engineering.

[23]  William H. Press,et al.  Numerical Recipes in C, 2nd Edition , 1992 .

[24]  E L Morin,et al.  Sampling, noise-reduction and amplitude estimation issues in surface electromyography. , 2002, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[25]  K. An,et al.  Determination of forces in extensor pollicis longus and flexor pollicis longus of the thumb. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[26]  R M Enoka,et al.  Long-term activity in upper- and lower-limb muscles of humans. , 2001, Journal of applied physiology.

[27]  A. Schultz,et al.  Identification of dynamic myoelectric signal-to-force models during isometric lumbar muscle contractions. , 1994, Journal of biomechanics.

[28]  Richard L. Scheaffer,et al.  Probability and statistics for engineers , 1986 .

[29]  G. Gottlieb,et al.  Dynamic relationship between isometric muscle tension and the electromyogram in man. , 1971, Journal of applied physiology.

[30]  D. Lloyd,et al.  An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo. , 2003, Journal of biomechanics.

[31]  Jim R Potvin,et al.  Effects of EMG processing on biomechanical models of muscle joint systems: sensitivity of trunk muscle moments, spinal forces, and stability. , 2007, Journal of biomechanics.

[32]  R. Snee,et al.  Ridge Regression in Practice , 1975 .

[33]  G M Hägg,et al.  Normalization of surface EMG amplitude from the upper trapezius muscle in ergonomic studies - A review. , 1995, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[34]  Thomas Schmitz-Rode,et al.  Surface electromyography and muscle force: limits in sEMG-force relationship and new approaches for applications. , 2009, Clinical biomechanics.

[35]  Z. Hasan,et al.  Isometric torque-angle relationship and movement-related activity of human elbow flexors: implications for the equilibrium-point hypothesis. , 1985, Experimental brain research.

[36]  Neville Hogan,et al.  Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part II: Experimental Demonstration of Optimal Myoprocessor Performance , 1980, IEEE Transactions on Biomedical Engineering.

[37]  Günter Hommel,et al.  A Human--Exoskeleton Interface Utilizing Electromyography , 2008, IEEE Transactions on Robotics.

[38]  Roberto Merletti,et al.  Applications in Ergonomics , 2004 .

[39]  Terence D Sanger,et al.  Bayesian filtering of myoelectric signals. , 2007, Journal of neurophysiology.

[40]  Jaap H van Dieën,et al.  Methodological aspects of SEMG recordings for force estimation--a tutorial and review. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[41]  N. Hogan,et al.  Relating agonist-antagonist electromyograms to joint torque during isometric, quasi-isotonic, nonfatiguing contractions , 1997, IEEE Transactions on Biomedical Engineering.

[42]  Carlo Menon,et al.  Surface EMG pattern recognition for real-time control of a wrist exoskeleton , 2010, Biomedical engineering online.

[43]  Roberto Merletti,et al.  Automatic segmentation of surface EMG images: Improving the estimation of neuromuscular activity. , 2010, Journal of biomechanics.

[44]  Jacob Rosen,et al.  A myosignal-based powered exoskeleton system , 2001, IEEE Trans. Syst. Man Cybern. Part A.

[45]  Evelyn Morin,et al.  Use of the Fast Orthogonal Search Method to Estimate Optimal Joint Angle For Upper Limb Hill-Muscle Models , 2010, IEEE Transactions on Biomedical Engineering.