Polyethylene post failure in posterior stabilized total knee arthroplasty.

Posterior-stabilized (PS) prostheses have been used extensively in total knee arthroplasty (TKA), with excellent long-term results. The key feature of these prostheses is the femoral cam and tibial post mechanism that limits posterior displacement and produces femoral rollback. Although articular-surface polyethylene wear of the tibial component has not been a significant clinical problem, tibial post wear has been reported. In distinction to chronic post wear, little information exists about catastrophic post failure. We present the case of a 56-year-old woman who presented 63 months after TKA with a PS prosthesis with acute fracture of the polyethylene post. The evaluation and treatment of this patient, including the previously unreported use of computed tomography arthrography to diagnose this rare problem, is reviewed.

[1]  G. Engh,et al.  In Vivo Deterioration of Tibial Baseplate Locking Mechanisms in Contemporary Modular Total Knee Components , 2001, The Journal of bone and joint surgery. American volume.

[2]  B. K. Vaughn,et al.  Dislocation following primary posterior-stabilized total knee arthroplasty. , 1993, The Journal of arthroplasty.

[3]  Melinda K Harman,et al.  Mechanism of anterior impingement damage in total knee arthroplasty. , 2002, The Journal of bone and joint surgery. American volume.

[4]  A. Lombardi,et al.  Fracture of the tibial spine of a Total Condylar III knee prosthesis secondary to malrotation of the femoral component. , 2001, The American journal of knee surgery.

[5]  J. D'arcy,et al.  Fracture of the polyethylene tibial post in posterior stabilized (Insall Burstein II) total knee arthroplasty. , 2000, The Journal of arthroplasty.

[6]  J. Moreland Mechanisms of failure in total knee arthroplasty. , 1988, Clinical orthopaedics and related research.

[7]  K. Vince,et al.  Breakage of a Total Condylar III knee prosthesis. A case report. , 1993, The Journal of arthroplasty.

[8]  P. Campbell,et al.  Tibial Post Impingement in Posterior-Stabilized Total Knee Arthroplasty , 2002, Clinical orthopaedics and related research.

[9]  G. Finerman,et al.  Catastrophic Wear of Tibial Polyethylene Inserts , 1991, Clinical orthopaedics and related research.

[10]  J. Lonner,et al.  Prodromes of failure in total knee arthroplasty. , 1999, The Journal of arthroplasty.

[11]  M A Ritter,et al.  Long-Term Followup of Anatomic Graduated Components Posterior Cruciate-Retaining Total Knee Replacement , 2001, Clinical orthopaedics and related research.

[12]  R B Bourne,et al.  Tibial Post Wear in Posterior Stabilized Total Knee Arthroplasty: An Unrecognized Source of Polyethylene Debris , 2001, The Journal of bone and joint surgery. American volume.

[13]  G. Scuderi**,et al.  The posterior stabilized total knee prosthesis. Assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up. , 1995, The Journal of bone and joint surgery. American volume.