Non-destructive evaluation of slot-die-coated lithium secondary battery electrodes by in-line laser caliper and IR thermography methods

Non-destructive, in-line quality control methods were adopted for evaluating the thickness and homogeneity of wet and dry lithium secondary battery electrodes. Laser caliper and infrared (IR) thermography methods were implemented in a systematic fashion for the first time to evaluate the quality of electrodes during the coating process on a slot-die coater. Laser caliper sensors were mounted, aligned, and subsequently calibrated at the oven inlet of the coating line in order to examine the thicknesses of different cathodes and anodes. The effect of various factors such as substrate vibration, temperature, surface reflectivity and laser positions on the thickness measurement during slot-die coating were evaluated. The setup was used to monitor the wet thickness of the cathode and anode, and the precision of the in-line laser thickness measurement was determined to be less than ±2%. Thickness deviation for cathodes was typically ±2.0–2.3%, and for anodes it was typically ±2.2–2.6%, which confirms excellent precision of the measurement. The homogeneity of the dried electrodes was also evaluated by IR thermography at the oven outlet of the coating line. Temperature profiles from thermography images of dry electrodes were carefully examined to detect any flaws and inhomogeneity present in the electrodes. An increase or decrease in the temperature profiles indicated defects/flaws in the electrodes that could not be observed in optical images. The techniques applied in this work will be helpful for detection of electrode flaws and contamination during large-scale manufacturing and to identify flawed product prior to lithium-ion cell assembly.

[1]  Petr Novák,et al.  Raman microscopy as a quality control tool for electrodes of lithium-ion batteries , 2001 .

[2]  Claus Daniel,et al.  Lithium Ion Cell Performance Enhancement Using Aqueous LiFePO4 Cathode Dispersions and Polyethyleneimine Dispersant , 2013 .

[3]  Claus Daniel,et al.  Optimization of LiFePO4 nanoparticle suspensions with polyethyleneimine for aqueous processing. , 2012, Langmuir : the ACS journal of surfaces and colloids.

[4]  G. Bender,et al.  Applying infrared thermography as a quality-control tool for the rapid detection of polymer-electrolyte-membrane-fuel-cell catalyst-layer-thickness variations , 2012 .

[5]  Y. Nishi Lithium ion secondary batteries; past 10 years and the future , 2001 .

[6]  Claus Daniel,et al.  Superior Performance of LiFePO4 Aqueous Dispersions via Corona Treatment and Surface Energy Optimization , 2012 .

[7]  Debasish Mohanty,et al.  Structural transformation of a lithium-rich Li1.2Co0.1Mn0.55Ni0.15O2 cathode during high voltage cycling resolved by in situ X-ray diffraction , 2013 .

[8]  Debasish Mohanty,et al.  Structural transformation in a Li1.2Co0.1Mn0.55Ni0.15O2 lithium-ion battery cathode during high-voltage hold , 2013 .

[9]  Claus Daniel,et al.  Materials processing for lithium-ion batteries , 2011 .

[10]  Claus Daniel,et al.  Optimization of multicomponent aqueous suspensions of lithium iron phosphate (LiFePO4) nanoparticles and carbon black for lithium-ion battery cathodes. , 2013, Journal of colloid and interface science.

[11]  Debasish Mohanty,et al.  Investigating phase transformation in the Li1.2Co0.1Mn0.55Ni0.15O2 lithium-ion battery cathode during high-voltage hold (4.5 V) via magnetic, X-ray diffraction and electron microscopy studies , 2013 .

[12]  R. J. Hill,et al.  Quantitative phase analysis from neutron powder diffraction data using the Rietveld method , 1987 .