Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System

Real-time monitoring of cardiac health is helpful for patients with cardiovascular disease. Many telemedicine systems based on ubiquitous computing and communication techniques have been proposed for monitoring the user's electrocardiogram (ECG) anywhere and anytime. Usually, wet electrodes are used in these telemedicine systems. However, wet electrodes require conduction gels and skin preparation that can be inconvenient and uncomfortable for users. In order to overcome this issue, a new non-contact electrode circuit was proposed and applied in developing a mobile electrocardiogram monitoring system. The proposed non-contact electrode can measure bio-potentials across thin clothing, allowing it to be embedded in a user's normal clothing to monitor ECG in daily life. We attempted to simplify the design of these non-contact electrodes to reduce power consumption while continuing to provide good signal quality. The electrical specifications and the performance of monitoring arrhythmia in clinical settings were also validated to investigate the reliability of the proposed design. Experimental results show that the proposed non-contact electrode provides good signal quality for measuring ECG across thin clothes.

[1]  Ko Keun Kim,et al.  A Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals , 2012, IEEE Transactions on Information Technology in Biomedicine.

[2]  Bor-Shing Lin,et al.  RTWPMS: A Real-Time Wireless Physiological Monitoring System , 2006, IEEE Transactions on Information Technology in Biomedicine.

[3]  Mohd Fadlee A. Rasid,et al.  Bluetooth telemedicine Processor for multichannel biomedical signal transmission via mobile cellular networks , 2005, IEEE Transactions on Information Technology in Biomedicine.

[4]  Steffen Leonhardt,et al.  A capacitive ECG array with visual patient feedback , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[5]  Yuan-Hsiang Lin,et al.  A wireless PDA-based physiological monitoring system for patient transport , 2004, IEEE Transactions on Information Technology in Biomedicine.

[6]  Paul Lukowicz,et al.  AMON: a wearable multiparameter medical monitoring and alert system , 2004, IEEE Transactions on Information Technology in Biomedicine.

[7]  T. Jung,et al.  Dry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces , 2012, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.

[9]  Jyh-Yeong Chang,et al.  Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement , 2011, IEEE Transactions on Biomedical Engineering.

[10]  Shing-Chi Cheung,et al.  Alerts in mobile healthcare applications: requirements and pilot study , 2004, IEEE Transactions on Information Technology in Biomedicine.

[11]  Masaaki Makikawa,et al.  ECG monitoring of a car driver using capacitively-coupled electrodes , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Chwan-Lu Tseng,et al.  A Mobile Care System With Alert Mechanism , 2007, IEEE Transactions on Information Technology in Biomedicine.

[13]  Chin-Teng Lin,et al.  An Intelligent Telecardiology System Using a Wearable and Wireless ECG to Detect Atrial Fibrillation , 2010, IEEE Transactions on Information Technology in Biomedicine.

[14]  S. Leonhardt,et al.  Characterization of textile electrodes and conductors using standardized measurement setups , 2010, Physiological measurement.

[15]  Robert Puers,et al.  Towards the integration of textile sensors in a wireless monitoring suit , 2004 .

[16]  M Oehler,et al.  A multichannel portable ECG system with capacitive sensors , 2008, Physiological measurement.