Optimal carbon dioxide application for organ protection in cardiac surgery.

BACKGROUND Cardiac surgery is associated with an important risk of central or peripheral organ damage, attributed in part to air embolism from incompletely deaired cardiac chambers. Insufflation of carbon dioxide into the thoracic cavity is widely used for organ protection in cardiac surgery. METHODS In patients operated on through a sternotomy, the gas was insufflated through a standard cardioplegia line (group I, n = 10) or a Jackson-Pratt drain (group II, n = 10), with flow rates of 2, 4, and 6 L/min. In patients undergoing mitral valve surgery through a right anterolateral minithoracotomy, application through a gas port (group III, n = 10) was compared with application through a Veress needle (group IV, n = 10). In groups I and IV measurements were repeated with a gauze sponge to divert the gas stream. RESULTS At a flow of 2 L/min, carbon dioxide levels in the thoracic cavity reached 52% +/- 30% in group I and increased to 81% +/- 27% when a gauze sponge was used. In group II a level of 91% +/- 5% was achieved. In minimally invasive procedures carbon dioxide levels reached 92% +/- 6% in group III and 60% +/- 25% in group IV without a gauze sponge and 97% +/- 2% in group IV with a gauze sponge. Increasing flow rates from 2 to 6 L/min decreased carbon dioxide levels in the thoracic cavity. Arterial blood gas analysis did not reveal critical levels of partial pressure of carbon dioxide at any time. CONCLUSIONS For optimized carbon dioxide concentrations during cardiac procedures, jet effects in the thoracic cavity have to be avoided. The highest levels were achieved with infusion lines covered by a gauze sponge or a perforated drain for conventional operations and a sponge-covered Veress needle or a gas port for minimally invasive approaches.

[1]  C. Peniston,et al.  Neuropsychologic impairment after coronary bypass surgery: effect of gaseous microemboli during perfusionist interventions. , 2001, The Journal of thoracic and cardiovascular surgery.

[2]  L. Svensson,et al.  Carbon dioxide field flooding techniques for open heart surgery: monitoring and minimizing potential adverse effects , 2000, Perfusion.

[3]  D. Eckmann,et al.  Theoretical and experimental intravascular gas embolism absorption dynamics. , 1999, Journal of applied physiology.

[4]  M. Lippmann Complications of CO2 flooding the surgical field in open heart surgery: an old technique revisited. , 1998, Anesthesia and analgesia.

[5]  B. Kussman,et al.  Severe hypercarbia during cardiopulmonary bypass: a complication of CO2 flooding of the surgical field. , 1998, Anesthesia and analgesia.

[6]  P. Moulder,et al.  Carbon dioxide field flooding minimizes residual intracardiac air after open heart operations. , 1997, The Annals of thoracic surgery.

[7]  W. Baumgartner,et al.  Cognitive outcome after coronary artery bypass: a one-year prospective study. , 1997, The Annals of thoracic surgery.

[8]  J. van der Linden,et al.  When do cerebral emboli appear during open heart operations? A transcranial Doppler study. , 1991, The Annals of thoracic surgery.

[9]  M. Rosen,et al.  Carbon dioxide in the prevention of air embolism during open-heart surgery , 1968, Thorax.

[10]  W. A. McAlpine,et al.  An effective method of replacing air in the chest with CO2 during open-heart surgery. , 1967, The Journal of thoracic and cardiovascular surgery.

[11]  T. Ferguson,et al.  Carbon dioxide flooding of the chest in open-heart surgery. A potential hazard. , 1965, The Journal of thoracic and cardiovascular surgery.

[12]  Moore Rm,et al.  INJECTIONS OF AIR AND OF CARBON DIOXIDE INTO A PULMONARY VEIN. , 1940 .