Design-oriented analysis of DC bus dynamics in adjustable speed drives under input voltage unbalance and sag conditions

Utility power quality problems like input voltage unbalance and sag conditions severely stress diode bridge rectifiers used in adjustable-speed drive (ASD) equipment. The key phenomenon that causes these problems is the transition of the rectifier from three-phase to single-phase operation. This is accompanied by increased harmonic currents that shorten the dc-bus capacitor life span. In addition, the bus ripple voltage causes undesired harmonic phase currents in Volts-per-Hertz ac drives, leading to elevated machine heating and the generation of pulsating torque at the second line harmonic (i.e., 120 Hz). This paper develops closed-form expressions that lay a solid foundation to analyze and quantify these phenomena, making it much easier to investigate alternative mitigation strategies. The paper identifies the boundary conditions that determine the entry of the rectifier stage into single-phase operation under unbalanced voltage sag conditions. Closed-form equations for the dc bus voltage and current are derived valid for finite line impedance, finite bus capacitance and varying loads. These expressions make it possible to conveniently conduct parametric studies of the system behavior under wide ranges of operating conditions without resorting to time-consuming time-domain simulations. Simulation and experimental tests are used to verify the accuracy and effectiveness of the analysis by comparing key predicted power quality performance indices (e.g., input power factor, current crest factor, THD) to simulated and measured values using a 5 hp ASD system.

[1]  P.N. Enjeti,et al.  Effect of voltage sags on adjustable speed drives-a critical evaluation and an approach to improve its performance , 1999, APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285).

[2]  D. O. Koval,et al.  Canadian national power quality survey: frequency and duration of voltage sags and surges at industrial sites , 1998 .

[3]  J. L. Stevens,et al.  The service life of large aluminum electrolytic capacitors: effects of construction and application , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[4]  C. J. Melhorn,et al.  Interpretation and analysis of power quality measurements , 1995 .

[5]  M. H. J. Bollen,et al.  Voltage Sags in Three-Phase Systems , 2001, IEEE Power Engineering Review.

[6]  A.E. Emanuel,et al.  Induction motor thermal aging caused by voltage distortion and imbalance: loss of useful life and its estimated cost , 2001, 2001 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record (Cat. No.01CH37226).

[7]  D. Lineweber,et al.  The Cost of Power Disturbances to Industrial & Digital Economy Companies , 2001 .

[8]  Math Bollen,et al.  Analysis of voltage tolerance of AC adjustable-speed drives for three-phase balanced and unbalanced sags , 1999, 1999 IEEE Industrial and Commercial Power Systems Technical Conference (Cat. No.99CH36371).

[9]  Math Bollen Characterisation of voltage sags experienced by three-phase adjustable-speed drives , 1997 .

[10]  S. Williamson,et al.  Pulsating torque and losses in multiphase induction machines , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[11]  T.A. Lipo,et al.  Closed-form analysis of adjustable speed drive performance under input voltage unbalance and sag conditions , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).