Natural convective heat transfer in a walled CCPC with PV cell.

The free convective heat transfer phenomenon in an isolated, walled CCPC with PV cell is studied experimentally at 1000 W/m2 irradiance and 28.5 {deg}C ambient temperature as well as 0{deg}, 10{deg}, 20{deg}, 30{deg} and 40{deg} incidences in indoor laboratory by using solar simulator. Then a series of numerical simulations are launched to estimate the CCPC natural heat transfer behaviour and optical performance based on steady heat transfer and laminar flow models with grey optical option. It is identified that the heat transfer and optical performances of CCPC are dependent on the incidence. Especially, the PV cell is subject to the highest temperature at an incidence less than 20{deg}, and otherwise the top glass cover is with the highest temperature. The predicted temperatures, Nusselt numbers and heat loss ratios are consistent with the experimental observations basically, especially at the incidence less than 20{deg} with (-10.1~+3) % error in temperature, (-35.6~+12.6) % in Nusselt number, and (-1.2~+20.5) % in CCPC wall heat loss ratio. The optical parameters predicted agree very well with the measurements. The heat loss from the CCPC walls accounts for nearly 60% of the total incoming solar irradiance and should be paid significant attention in the design of CCPC.

[1]  Mervyn Smyth,et al.  The experimental validation of a comprehensive unified model for optics and heat transfer in line-axis solar energy systems , 2001 .

[2]  C. Zauner,et al.  Heat transfer mechanisms in a compound parabolic concentrator: Comparison of computational fluid dynamics simulations to particle image velocimetry and local temperature measurements , 2013 .

[3]  Philip C. Eames,et al.  Validated, unified model for optics and heat transfer in line-axis concentrating solar energy collectors , 1993 .

[4]  John W. Mitchell,et al.  Convective heat transfer in vee-trough linear concentrators , 1982 .

[5]  G. Rybicki Radiative transfer , 2019, Climate Change and Terrestrial Ecosystem Modeling.

[6]  Tapas K. Mallick,et al.  Using air flow to alleviate temperature elevation in solar cells within asymmetric compound parabolic concentrators , 2007 .

[7]  Nabin Sarmah,et al.  Design and performance evaluation of a low concentrating line-axis dielectric photovoltaic system , 2012 .

[8]  Tapas K. Mallick,et al.  Optical efficiency study of PV Crossed Compound Parabolic Concentrator , 2013 .

[9]  Philip C. Eames,et al.  A review of natural convective heat transfer correlations in rectangular cross-section cavities and their potential applications to compound parabolic concentrating (CPC) solar collector cavities , 2011 .

[10]  Tapas K. Mallick,et al.  Performance analysis of a reflective 3D crossed compound parabolic concentrating photovoltaic system for building façade integration , 2012 .

[11]  Aldo Steinfeld,et al.  Performance of compound parabolic concentrators with polygonal apertures , 2013 .

[12]  J. Simonson,et al.  Engineering heat transfer , 1975 .

[13]  Brian Norton,et al.  Convective heat transfers within air spaces of compound parabolic concentrating solar-energy collectors , 1987 .

[14]  T. Anderson Natural convection heat transfer in V-trough solar concentrators , 2013 .

[15]  Philip C. Eames,et al.  Detailed parametric analyses of heat transfer in CPC solar energy collectors , 1993 .

[16]  H. P. Garg,et al.  Performance analysis of a hybrid photovoltaic/thermal (PV/T) collector with integrated CPC troughs , 1999 .

[17]  Tapas K. Mallick,et al.  Numerical investigations of solar cell temperature for photovoltaic concentrator system with and without passive cooling arrangements , 2011 .

[18]  W. Li Experimental and numerical investigation of thermal performance of a crossed compound parabolic concentrator with PV cell , 2016 .

[19]  K. S. Ong Thermal performance of solar air heaters: Mathematical model and solution procedure , 1995 .

[20]  A. Fasulo,et al.  Development of a CPC with low thermal losses , 1987 .

[21]  Björn Karlsson,et al.  Experimental investigation of heat losses from low-concentrating non-imaging concentrators , 1996 .

[22]  Eduardo F. Fernández,et al.  Coupled Simulation of Performance of a Crossed Compound Parabolic Concentrator with Solar Cell , 2015 .

[23]  Philip C. Eames,et al.  Modelling line-axis solar concentrators in the medium temperature range , 1999 .

[24]  João C.C. Henriques,et al.  Impact of different internal convection control strategies in a non-evacuated CPC collector performance , 2012 .

[25]  Philip C. Eames,et al.  Correlations for natural convective heat exchange in CPC solar collector cavities determined from experimental measurements , 2012 .

[26]  Tapas K. Mallick,et al.  Electrical performance evaluation of low-concentrating non-imaging photovoltaic concentrator , 2008 .

[27]  M. Shin,et al.  Thermal Characterization of Junction in Solar Cell Packages , 2010, IEEE Electron Device Letters.

[28]  H. P. Garg,et al.  Transient simulation of conventional hybrid photovoltaic/thermal (PV/T) air heating collectors , 1998 .

[29]  Bin-Juine Huang,et al.  Solar cell junction temperature measurement of PV module , 2011 .