Recurrent Neural Network for Partial Discharge Diagnosis in Gas-Insulated Switchgear

The analysis of partial discharge (PD) signals has been identified as a standard diagnostic tool for monitoring the condition of different electrical apparatuses. This study proposes an approach to detecting PD patterns in gas-insulated switchgear (GIS) using a long short-term memory (LSTM) recurrent neural network (RNN). The proposed method uses phase-resolved PD (PRPD) signals as input, extracts low-level features, and finally, classifies faults in GIS. In the proposed method, LSTM networks can learn temporal dependencies directly from PRPD signals. Most existing models use support vector machines (SVMs) and mainly focus on improving feature representation and extraction manually to analyze PRPD signals. However, the proposed model captures important temporal features with the help of its low-level feature extraction capability from raw inputs. It outperforms conventional SVMs and achieves 96.74% classification accuracy for PRPDs in GIS.

[1]  Weidong Liu,et al.  Research on the Typical Partial Discharge Using the UHF Detection Method for GIS , 2011, IEEE Transactions on Power Delivery.

[2]  Lukás Burget,et al.  Recurrent neural network based language model , 2010, INTERSPEECH.

[3]  Jawad Faiz,et al.  Dissolved gas analysis evaluation in electric power transformers using conventional methods a review , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Jieming Zhang,et al.  Feature extraction of GIS partial discharge signal based on S-transform and singular value decomposition , 2017 .

[5]  Guillermo Robles,et al.  Multiple partial discharge source discrimination with multiclass support vector machines , 2016, Expert Syst. Appl..

[6]  Yu-Hsun Lin Using K-Means Clustering and Parameter Weighting for Partial-Discharge Noise Suppression , 2011, IEEE Transactions on Power Delivery.

[7]  Xiaohua Wang,et al.  Development simulation and experiment study on UHF Partial Discharge Sensor in GIS , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[8]  Jürgen Schmidhuber,et al.  Long Short-Term Memory , 1997, Neural Computation.

[9]  Jianfang Li,et al.  UHF Moore Fractal Antennas for Online GIS PD Detection , 2017, IEEE Antennas and Wireless Propagation Letters.

[10]  C.S. Chang,et al.  Separation of corona using wavelet packet transform and neural network for detection of partial discharge in gas-insulated substations , 2005, IEEE Transactions on Power Delivery.

[11]  Alain Girodet,et al.  Partial discharge analysis of gas insulated systems at high voltage AC and DC , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  Chih-Jen Lin,et al.  Linear and Kernel Classification: When to Use Which? , 2016, SDM.

[13]  Ricardo Albarracín Sánchez,et al.  Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors , 2018, Sensors.

[14]  W R Si,et al.  Investigation of a comprehensive identification method used in acoustic detection system for GIS , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  K. Feser,et al.  The application of ultra-high-frequency partial discharge measurements to gas-insulated substations , 1998 .

[16]  Martín Abadi,et al.  TensorFlow: Large-Scale Machine Learning on Heterogeneous Distributed Systems , 2016, ArXiv.

[17]  Hai-Bao Mu,et al.  Classification and separation of partial discharge ultra-high-frequency signals in a 252 kV gas insulated substation by using cumulative energy technique , 2016 .

[18]  Ming Ren,et al.  Electrochemical and Infrared Absorption Spectroscopy Detection of SF6 Decomposition Products , 2017, Sensors.

[19]  Yilu Liu,et al.  Partial discharge recognition in gas insulated switchgear based on multi-information fusion , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  M.D. Judd,et al.  Partial discharge monitoring of power transformers using UHF sensors. Part I: sensors and signal interpretation , 2005, IEEE Electrical Insulation Magazine.

[21]  Corinna Cortes,et al.  Support-Vector Networks , 1995, Machine Learning.

[22]  H. Muto,et al.  Propagation characteristics of electromagnetic waves in three-phase-type tank from viewpoint of partial discharge diagnosis on gas insulated switchgear , 2009, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  Chengke Zhou,et al.  Application of K-Means method to pattern recognition in on-line cable partial discharge monitoring , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  S. Tenbohlen,et al.  Risk assessment on defects in GIS based on PD diagnostics , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[25]  S. Tenbohlen,et al.  UHF partial discharge detection system for GIS: Application guide for sensitivity verification: CIGRE WG D1.25 , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[26]  Guigang Zhang,et al.  Deep Learning , 2016, Int. J. Semantic Comput..

[27]  Matthew D. Zeiler ADADELTA: An Adaptive Learning Rate Method , 2012, ArXiv.

[28]  Jimmy Ba,et al.  Adam: A Method for Stochastic Optimization , 2014, ICLR.

[29]  Geoffrey E. Hinton,et al.  Speech recognition with deep recurrent neural networks , 2013, 2013 IEEE International Conference on Acoustics, Speech and Signal Processing.

[30]  S. Tenbohlen,et al.  Detection and location of partial discharges in power transformers using acoustic and electromagnetic signals , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[31]  Firdaus Muhammad-Sukki,et al.  An ensemble-boosting algorithm for classifying partial discharge defects in electrical assets. , 2017 .

[32]  Joseph W. Spencer,et al.  Acoustic monitoring of partial discharges in gas insulated substations using optical sensors , 1993 .

[33]  Quoc V. Le,et al.  Sequence to Sequence Learning with Neural Networks , 2014, NIPS.

[34]  I. Cotton,et al.  Dissolved gas analysis of alternative fluids for power transformers , 2007, IEEE Electrical Insulation Magazine.

[35]  Dongbo Zhao,et al.  Investigation of frequency characteristics of typical PD and the propagation properties in GIS , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[36]  Magdy M. A. Salama,et al.  Partial discharge pattern classification using the fuzzy decision tree approach , 2005, IEEE Transactions on Instrumentation and Measurement.

[37]  Yoram Singer,et al.  Adaptive Subgradient Methods for Online Learning and Stochastic Optimization , 2011, J. Mach. Learn. Res..

[38]  Firdaus Muhammad-Sukki,et al.  Comparison of the performance of artificial neural networks and fuzzy logic for recognizing different partial discharge sources , 2017 .

[39]  Min Wu,et al.  An overview of state-of-the-art partial discharge analysis techniques for condition monitoring , 2015, IEEE Electrical Insulation Magazine.

[40]  Geoffrey E. Hinton,et al.  Visualizing Data using t-SNE , 2008 .

[41]  Firdaus Muhammad-Sukki,et al.  Artificial Neural Network Application for Partial Discharge Recognition: Survey and Future Directions , 2016 .

[42]  Xiaodong Cui,et al.  Data augmentation for deep convolutional neural network acoustic modeling , 2015, 2015 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[43]  B. F. Hampton,et al.  The excitation of UHF signals by partial discharges in GIS , 1996 .

[44]  Masayuki Hikita,et al.  New aspects of UHF PD diagnostics on gas-insulated systems , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[45]  Wei Li,et al.  GIS partial discharge pattern recognition based on the chaos theory , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.