Mitigation of Motor Stalling and FIDVR via Energy Storage Systems With Signal Temporal Logic

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. In this paper, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

[1]  Thomas J. Overbye,et al.  An Authenticated Control Framework for Distributed Voltage Support on the Smart Grid , 2010, IEEE Transactions on Smart Grid.

[2]  J. M. Maestre,et al.  Distributed Model Predictive Control: An Overview and Roadmap of Future Research Opportunities , 2014, IEEE Control Systems.

[3]  Aleksandar M. Stankovic,et al.  Modeling and analysis of single-phase induction machines with dynamic phasors , 1999 .

[4]  Shanshan Liu,et al.  Dynamic Optimization Based Reactive Power Planning to Mitigate Slow Voltage Recovery and Short Term Voltage Instability , 2013, IEEE Transactions on Power Systems.

[5]  Zhenyu Huang,et al.  Air Conditioner Compressor Performance Model , 2008 .

[6]  Bernard Lesieutre,et al.  FINAL PROJECT REPORTLOAD MODELING TRANSMISSION RESEARCH , 2013 .

[7]  Christoforos N. Hadjicostis,et al.  A Two-Stage Distributed Architecture for Voltage Control in Power Distribution Systems , 2013, IEEE Transactions on Power Systems.

[8]  Anurag K. Srivastava,et al.  Impact of Distributed Generations With Energy Storage Devices on the Electric Grid , 2012, IEEE Systems Journal.

[9]  Kevin Tomsovic,et al.  Secondary Voltage Control Via Demand-Side Energy Storage with Temporal Logic Specifications , 2019, 2019 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).

[10]  S. Imai Undervoltage load shedding improving security as reasonable measure for extreme contingencies , 2005, IEEE Power Engineering Society General Meeting, 2005.

[11]  G.K. Stefopoulos,et al.  Induction Motor Load Dynamics: Impact on Voltage Recovery Phenomena , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[12]  Honghao Zheng,et al.  A New Dynamic Performance Model of Motor Stalling and FIDVR for Smart Grid Monitoring/Planning , 2016, IEEE Transactions on Smart Grid.

[13]  Sharad W. Mohod,et al.  Micro Wind Power Generator With Battery Energy Storage for Critical Load , 2012, IEEE Systems Journal.

[14]  Kevin Tomsovic,et al.  Model predictive control for voltage restoration in microgrids using temporal logic specifications , 2020 .

[15]  S. Ihara,et al.  Modeling air conditioner load for power system studies , 1998 .

[16]  Hongbin Sun,et al.  Review of Challenges and Research Opportunities for Voltage Control in Smart Grids , 2019, IEEE Transactions on Power Systems.

[17]  J. Lofberg,et al.  YALMIP : a toolbox for modeling and optimization in MATLAB , 2004, 2004 IEEE International Conference on Robotics and Automation (IEEE Cat. No.04CH37508).

[18]  C. DeMarco A phase transition model for cascading network failure , 2001 .

[19]  Alberto L. Sangiovanni-Vincentelli,et al.  A Contract-Based Methodology for Aircraft Electric Power System Design , 2014, IEEE Access.

[20]  Vaithianathan Venkatasubramanian,et al.  Hierarchical Two-Level Voltage Controller for Large Power Systems , 2016, IEEE Transactions on Power Systems.

[21]  Thomas J. Overbye,et al.  An energy based security measure for assessing vulnerability to voltage collapse , 1990 .

[22]  Ali Davoudi,et al.  Signal Temporal Logic-Based Attack Detection in DC Microgrids , 2019, IEEE Transactions on Smart Grid.

[23]  James D. McCalley,et al.  Optimal planning of static and dynamic reactive power resources , 2014 .

[24]  V Ajjarapu,et al.  A Novel Online Load Shedding Strategy for Mitigating Fault-Induced Delayed Voltage Recovery , 2011, IEEE Transactions on Power Systems.

[25]  Alberto L. Sangiovanni-Vincentelli,et al.  Model predictive control with signal temporal logic specifications , 2014, 53rd IEEE Conference on Decision and Control.

[26]  Joe H. Chow,et al.  Energy Storage Controller Synthesis for Power Systems With Temporal Logic Specifications , 2019, IEEE Systems Journal.

[27]  A.R. Bergen,et al.  A Structure Preserving Model for Power System Stability Analysis , 1981, IEEE Transactions on Power Apparatus and Systems.

[28]  C. W. Taylor,et al.  Recording and analyzing the July 2 cascading outage [Western USA power system] , 1997 .

[29]  N. Narasimhamurthi,et al.  A generalized energy function for transient stability analysis of power systems , 1984 .

[30]  Calin Belta,et al.  A Temporal Logic Inference Approach for Model Discrimination , 2016, IEEE Life Sciences Letters.

[31]  C. Mozina,et al.  Undervoltage Load Shedding , 2007, 2007 60th Annual Conference for Protective Relay Engineers.

[32]  Ali Davoudi,et al.  Detection of False-Data Injection Attacks in Cyber-Physical DC Microgrids , 2017, IEEE Transactions on Industrial Informatics.