Subarray coherence based postfilter for eigenspace based minimum variance beamformer in ultrasound plane-wave imaging.

This paper introduces a new beamformer, which combines the eigenspace based minimum variance (ESBMV) beamformer with a subarray coherence based postfilter (SCBP), for improving the quality of ultrasound plane-wave imaging. The ESBMV beamformer has been validated in improving the imaging contrast, but the difficulty in dividing the signal subspace limits the usage of it in the low signal-to-noise ratio (SNR) scenarios. Coherence factor (CF) based methods could optimize the output of a distortionless beamformer to reduce sidelobes, but the influence by the subarray decorrelation technique on the postfilter design has not attracted enough concern before. Accordingly, an ESBMV-SCBP beamformer was proposed in this paper, which used the coherence of the subarray signal to compute an SCBP to optimize the ESBMV results. Simulated and experimental data were used to evaluate the performance of the proposed method. The results showed that the ESBMV-SCBP method achieved an improved imaging quality compared with the ESBMV beamformer. In the simulation study, the contrast ratio (CR) for an anechoic cyst was improved by 9.88 dB and the contrast-to-noise ratio (CNR) was improved by 0.97 over the ESBMV. In the experimental study, the CR improvements for two anechoic cysts were 7.32 dB and 9.45 dB, while the CNRs were improved by 1.27 and 0.66, respectively. The ESBMV-SCBP also showed advantages over the ESBMV-Wiener beamformer in preserving a less grainy speckle, which is closer to that of distortionless beamformers and benefits the imaging contrast. With a relatively small extra computational load, the proposed method has potential to enhance the quality of the ultrasound plane-wave imaging.

[1]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[2]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[3]  Sverre Holm,et al.  Implementing capon beamforming on a GPU for real-time cardiac ultrasound imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[4]  A. Austeng,et al.  Adaptive Beamforming Applied to Medical Ultrasound Imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Gene H. Golub,et al.  Matrix computations , 1983 .

[6]  Pai-Chi Li,et al.  MVDR-based coherence weighting for high-frame-rate adaptive imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Andreas Austeng,et al.  The iterative adaptive approach in medical ultrasound imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[8]  Pai-Chi Li,et al.  Adaptive imaging using the generalized coherence factor. , 2003, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[9]  M. Fink,et al.  Shear modulus imaging with 2-D transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  A. Austeng,et al.  Benefits of minimum-variance beamforming in medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Sverre Holm,et al.  Eigenspace Based Minimum Variance Beamforming Applied to Ultrasound Imaging of Acoustically Hard Tissues , 2012, IEEE Transactions on Medical Imaging.

[12]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  A. Mahloojifar,et al.  A low-complexity adaptive beamformer for ultrasound imaging using structured covariance matrix , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  F. Gran,et al.  Broadband minimum variance beamforming for ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  A. Austeng,et al.  Adaptive Sonar Imaging Using Aperture Coherence , 2013, IEEE Journal of Oceanic Engineering.

[16]  Yuanyuan Wang,et al.  Eigenspace-based minimum variance beamformer combined with Wiener postfilter for medical ultrasound imaging. , 2012, Ultrasonics.

[17]  A. Mahloojifar,et al.  Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  A Mahloojifar,et al.  Contrast enhancement and robustness improvement of adaptive ultrasound imaging using forward-backward minimum variance beamforming , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  S. M. Sakhaei Optimum beamforming for sidelobe reduction in ultrasound imaging , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[20]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  B M Asl,et al.  Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Xin Yang,et al.  Spatio-temporally smoothed coherence factor for ultrasound imaging [Correspondence] , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[23]  Pai-Chi Li,et al.  SNR-dependent coherence-based adaptive imaging for high-frame-rate ultrasonic and photoacoustic imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[24]  Billy Y S Yiu,et al.  GPU-based minimum variance beamformer for synthetic aperture imaging of the eye. , 2015, Ultrasound in medicine & biology.

[25]  Sverre Holm,et al.  Wiener beamforming and the coherence factor in ultrasound imaging , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  Jian-yu Lu,et al.  Extended high-frame rate imaging method with limited-diffraction beams , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  G. Cloutier,et al.  Stolt's f-k migration for plane wave ultrasound imaging , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[28]  A. Austeng,et al.  Applying Thomson's multitaper approach to reduce speckle in medical ultrasound imaging , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  A. Austeng,et al.  An approach to multibeam covariance matrices for adaptive beamforming in ultrasonography , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  Mickael Tanter,et al.  Ultrafast imaging in biomedical ultrasound , 2014 .