Flow visualization study to improve hemocompatibility of a centrifugal blood pump.

A correlation study was conducted among quantitative flow visualization analysis, computational fluid dynamic analysis, and hemolysis tests regarding the flow in a centrifugal blood pump to prevent hemolysis. Particular attention was paid to the effect of the impeller/casing gap widths on the flow in the volute and in the outlet. Flow vector maps were obtained for 250% scaled-up models with various geometries, using an argon ion laser light sheet, a high speed video camera, and particle tracking velocimetry. In terms of the results, in the small radial gap model, high shear occurred near the inside wall of the outlet and stagnation near the outside wall of the outlet whereas the standard model maintained smooth flow and low shear. The small radial gap model showed a lower head and greater hemolysis than the standard model. This head decrease could be partly restored by relocating the outlet position; however, the hemolysis level hardly decreased. From these results, it was found that the small radial gap itself is important. It was also confirmed by detailed flow visualization and simple laminar shear analysis near the wall that the small radial gap caused a wider high shear layer (110-120 microm) than the standard model (approximately 80 microm). In the small radial gap model, the high shear layer in the outlet (approximately 50 microm) is much narrower than that in the volute. Flow visualization together with the aid of computational fluid dynamic analysis would be useful to eliminate the causes of hemolysis.

[1]  Y Miyazoe,et al.  Development of design methods for a centrifugal blood pump with a fluid dynamic approach: results in hemolysis tests. , 1999, Artificial organs.

[2]  T Noda,et al.  Development of an atraumatic small centrifugal pump for second-generation cardiopulmonary bypass. , 2008, Artificial organs.

[3]  Y Nosé,et al.  A fluid dynamic analysis of a rotary blood pump for design improvement. , 2008, Artificial organs.

[4]  Y Miyazoe,et al.  Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: results in hemolysis tests. , 1998, Artificial organs.

[5]  B Asztalos,et al.  Quantitative visualization of flow through a centrifugal blood pump: effect of washout holes. , 1997, Artificial organs.

[6]  Y Miyazoe,et al.  Computational fluid dynamic analyses to establish design process of centrifugal blood pumps. , 1998, Artificial organs.

[7]  Y Miyazoe,et al.  Computational fluid dynamics analysis to establish the design process of a centrifugal blood pump: second report. , 1999, Artificial organs.

[8]  T Tateishi,et al.  A quantitative visualization study of flow in a scaled-up model of a centrifugal blood pump. , 1996, Artificial organs.

[9]  Y Miyazoe,et al.  Flow visualization as a complementary tool to hemolysis testing in the development of centrifugal blood pumps. , 1998, Artificial organs.

[10]  Y Nosé,et al.  Cardiopulmonary bypass with Nikkiso and BioMedicus centrifugal pumps. , 1994, Artificial organs.

[11]  U Losert,et al.  Minimization of Hemolysis in Centrifugal Blood Pumps: Influence of Different Geometries , 1993, The International journal of artificial organs.