Tissue harmonic imaging

Harmonic imaging was originally developed for microbubble contrast agents in the early 90s under the assumption that tissue is linear and all harmonic echoes are generated by the bubbles. In fact, tissue, like bubbles, is a nonlinear medium. Whereas the harmonic echoes from bubbles have their origins in nonlinear scattering, those from tissue are a result of nonlinear propagation. The clinical benefits of tissue harmonic imaging are reduced reverberation noise and overall clutter level, improved border delineation, increased contrast resolution, and reduced phase aberration artifacts. To a large extend these benefits are explained by the properties of nonlinear propagation of the transmitted ultrasonic pulses in the tissue.

[1]  C. Chin,et al.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  M. Hamilton,et al.  Nonlinear distortion of short pulses radiated by plane and focused circular pistons. , 1997, The Journal of the Acoustical Society of America.

[3]  M. Averkiou,et al.  A new imaging technique based on the nonlinear properties of tissues , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[4]  A. C. Baker,et al.  The nonlinear pressure field of plane, rectangular apertures: Experimental and theoretical results , 1995 .

[5]  T. Christopher Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  M. Hamilton,et al.  Time‐domain modeling of pulsed finite‐amplitude sound beams , 1995 .

[7]  B. Lüderitz,et al.  Improvement in Endocardial Border Delineation Using Tissue Harmonic Imaging , 1998, Echocardiography.

[8]  W. K. Law,et al.  Demonstration of nonlinear acoustical effects at biomedical frequencies and intensities. , 1980, Ultrasound in medicine & biology.

[9]  A. C. Baker,et al.  Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound. , 1997, The Journal of the Acoustical Society of America.

[10]  Matthew Bruce,et al.  A generalization of pulse inversion Doppler , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[11]  E. Carstensen,et al.  Prediction of nonlinear acoustic effects at biomedical frequencies and intensities. , 1980, Ultrasound in medicine & biology.