Main ion charge exchange recombination spectroscopy on C-2W FRC plasmas.

A main ion charge exchange recombination spectroscopy (mChERS) diagnostic has been developed to measure the velocity and temperature of the main deuterium ions in the C-2W (also called Norman) field-reversed configuration (FRC) device. A modulated diagnostic neutral beam (DNB) of hydrogen with 40 keV full energy and a nominal current of 8.5 A provides the charge exchange signal. The DNB can achieve a fast modulation frequency of up to 10 kHz, a rare attribute to find on other fusion devices, which defines the time resolution of mChERS. Currently, the mChERS diagnostic provides simultaneous measurements at five spatial locations in the FRC plasma using a high-speed camera. The design and capabilities of the mChERS system are presented along with first experimental data.

[1]  M. Nations,et al.  Measurements of impurity ion temperature and velocity distributions via active charge-exchange recombination spectroscopy in C-2W. , 2021, The Review of scientific instruments.

[2]  M. Boyer,et al.  Active spectroscopy measurements of the deuterium temperature, rotation, and density from the core to scrape off layer on the DIII-D tokamak (invited). , 2018, The Review of scientific instruments.

[3]  M. Onofri,et al.  Equilibrium properties of hybrid field reversed configurations , 2017 .

[4]  Sean Dettrick,et al.  Recent breakthroughs on C-2U: Norman’s legacy , 2016 .

[5]  Sean Dettrick,et al.  A high performance field-reversed configurationa) , 2015 .

[6]  K. Burrell,et al.  Active spectroscopic measurements of the bulk deuterium properties in the DIII-D tokamak (invited). , 2012, The Review of scientific instruments.

[7]  D Gupta,et al.  Field reversed configuration confinement enhancement through edge biasing and neutral beam injection. , 2012, Physical review letters.

[8]  I. Hutchinson Statistical uncertainty in line shift and width interpretation , 2012, 1204.6436.

[9]  D. Q. Bui,et al.  A new high performance field reversed configuration operating regime in the C-2 devicea) , 2012 .

[10]  W. Heidbrink,et al.  A Code that Simulates Fast-Ion D(alpha) and Neutral Particle Measurements , 2011 .

[11]  Loren C. Steinhauer,et al.  Review of field-reversed configurations , 2011 .

[12]  L. Bonelli,et al.  Doppler spectroscopy and D-alpha emission diagnostics for the C-2 FRC plasma. , 2010, The Review of scientific instruments.

[13]  M. Tuszewski,et al.  Field reversed configurations , 1988 .

[14]  R. Isler A Review of Charge-Exchange Spectroscopy and Applications to Fusion Plasmas , 1987 .

[15]  R. Fonck Charge exchange recombination spectroscopy as a plasma diagnostic tool (invited) , 1985 .