Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy

The purpose of this study was to develop a computerized method for estimation of the location of a lung tumor in cine images on an electronic portal imaging device (EPID) without implanted markers during stereotactic body radiotherapy (SBRT). Each tumor region was segmented in the first EPID cine image, i.e., reference portal image, based on a multiple-gray level thresholding technique and a region growing technique, and then the image including the tumor region was cropped as a 'tumor template' image. The tumor location was determined as the position in which the tumor template image took the maximum cross-correlation value within each consecutive portal image, which was acquired in cine mode on the EPID in treatment. EPID images with 512 x 384 pixels (pixel size: 0.56 mm) were acquired at a sampling rate of 0.5 frame s(-1) by using energies of 4, 6 or 10 MV on linear accelerators. We applied our proposed method to EPID cine images (226 frames) of 12 clinical cases (ages: 51-83, mean: 72) with a non-small cell lung cancer. As a result, the average location error between tumor points obtained by our method and the manual method was 1.47 +/- 0.60 mm. This preliminary study suggests that our method based on the tumor template matching technique might be feasible for tracking the location of a lung tumor without implanted markers in SBRT.

[1]  Suresh Senan,et al.  4D imaging for target definition in stereotactic radiotherapy for lung cancer , 2006, Acta oncologica.

[2]  Joao Seco,et al.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects. , 2007, Medical physics.

[3]  Hidetaka Arimura,et al.  Computerized method for measurement of displacement vectors of target positions on EPID cine images in stereotactic radiotherapy , 2007, SPIE Medical Imaging.

[4]  Eike Rietzel,et al.  Design of 4D treatment planning target volumes. , 2006, International journal of radiation oncology, biology, physics.

[5]  Ross I Berbeco,et al.  Clinical feasibility of using an EPID in CINE mode for image-guided verification of stereotactic body radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[6]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[7]  Matthias Guckenberger,et al.  Tracking moving objects with megavoltage portal imaging: a feasibility study. , 2006, Medical physics.

[8]  R. Mohan,et al.  On the use of EPID-based implanted marker tracking for 4D radiotherapy. , 2004, Medical physics.

[9]  Steve B Jiang,et al.  Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking. , 2007, Physics in medicine and biology.

[10]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[11]  K. Doi,et al.  Computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening. , 2004, Academic radiology.

[12]  H Shirato,et al.  Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[13]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[14]  P Keall,et al.  Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery. , 2005, Medical physics.

[15]  Harold O. Wyckoff,et al.  International Commission ON Radiation Units and Measurements (ICRU). , 1974, The American journal of roentgenology, radium therapy, and nuclear medicine.

[16]  Kunio Doi,et al.  Development of a computerized method for identifying the posteroanterior and lateral views of chest radiographs by use of a template matching technique. , 2002, Medical physics.

[17]  Y Suh,et al.  Aperture maneuver with compelled breath (AMC) for moving tumors: a feasibility study with a moving phantom. , 2004, Medical physics.

[18]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[19]  Raj Shekhar,et al.  Automatic segmentation of phase-correlated CT scans through nonrigid image registration using geometrically regularized free-form deformation. , 2007, Medical physics.