NADH screen-printed electrodes modified with zirconium phosphate, Meldola blue, and Reinecke salt. Application to the detection of glycerol by FIA

Bulk screen-printed electrodes (bSPEs) modified with zirconium phosphate (ZrP) and Meldola blue (MB) and by electrochemical deposition of a Reineckate film (bMBZrPRs-SPEs) have been constructed and used as NADH sensors. Cyclic voltammetric investigation of these bulk electrochemically modified screen-printed electrodes revealed stable catalytic activity in oxidation of the reduced form of the coenzyme nicotinamide adenine dinucleotide (NADH). Flow-injection analysis (FIA) coupled with amperometric detection confirmed the improved stability of the bMBZrPRs-SPEs (10−4 mol L−1 NADH, %RSD = 4.2, n = 90, pH 7.0). Other conditions, for example applied working potential (+50 mV relative to Ag|AgCl), flow rate (0.30 mL min−1) and pH-dependence (range 4.0–10.0) were evaluated and optimized. A glycerol biosensor, prepared by immobilizing glycerol dehydrogenase (GDH) on the working electrode area of a bMBZrPRs-SPE, was also assembled. The biosensor was most stable at pH 8.5 (%RSD = 5.6, n = 70, 0.25 mmol L−1 glycerol). The detection and quantification limits were 2.8 × 10−6 and 9.4 × 10−6 mol L−1, respectively, and the linear working range was between 1.0 × 10−5 and 1.0 × 10−4 mol L−1. To assess the effect of interferences, and recovery by the probe we analyzed samples taken during fermentation of chemically defined grape juice medium and compared the results with those obtained by HPLC.

[1]  W. Schuhmann,et al.  Electrocatalytic oxidation of NADH at mediator-modified electrode surfaces , 1993 .

[2]  A. Eftekhari Glycerol biosensor based on glycerol dehydrogenase incorporated into polyaniline modified aluminum electrode using hexacyanoferrate as mediator , 2001 .

[3]  Camelia Bala,et al.  Strategies for developing NADH detectors based on Meldola Blue and screen-printed electrodes: a comparative study. , 2003, Talanta.

[4]  L. Gorton,et al.  Catalytic oxidation of NADH by surface-modified graphite electrodes , 1981 .

[5]  P. Gemeiner,et al.  Amperometric biosensors based on two different enzyme systems and their use for glycerol determination in samples from biotechnological fermentation process , 2006 .

[6]  L. Gorton,et al.  Electrochemical and SERS studies of chemically modified electrodes: Nile Blue A, a mediator for NADH oxidation , 1990 .

[7]  L. Gorton,et al.  Electrochemical Study of Flavins, Phenazines, Phenoxazines and Phenothiazines Immobilized on Zirconium Phosphate , 1999 .

[8]  J. V. Bannister,et al.  Amperometric NADH determination via both direct and mediated electron transfer by NADH oxidase from Thermus aquaticus YT-1 , 1994 .

[9]  J. Kulys,et al.  NADH oxidation by quinone electron acceptors. , 1984, Biochimica et biophysica acta.

[10]  L. Gorton,et al.  Effect of pH on the catalytic electrooxidation of NADH using different two-electron mediators immobilised on zirconium phosphate , 2001 .

[11]  B. Strehlitz,et al.  Mediator-modified electrodes for electrocatalytic oxidation of NADH , 1995 .

[12]  D. Vissers,et al.  THE EXCHANGE OF Li$sup +$, Na$sup +$ AND K$sup +$ WITH H$sup +$ ON ZIRCONIUM PHOSPHATE , 1960 .

[13]  Björn Persson,et al.  A chemically modified graphite electrode for electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide based on a phenothiazine derivative, 3-β-naphthoyl-toluidine blue O , 1990 .

[14]  C. Brett,et al.  Development and Applications of a Bienzymatic Amperometric Glycerol Biosensor Based on a Poly(Neutral Red) Modified Carbon Film Electrode , 2006 .

[15]  L. Gorton,et al.  A comparative study of some 3,7-diaminophenoxazine derivatives and related compounds for electrocatalytic oxidation of NADH , 1990 .

[16]  P. Tuñón,et al.  Amperometric biosensors based on NAD(P)‐dependent dehydrogenase enzymes , 1997 .

[17]  Theodore Kuwana,et al.  Electrocatalysis of dihydronicotinamide adenosine diphosphate with quinones and modified quinone electrodes , 1978 .

[18]  Valdas Laurinavicius,et al.  Properties and analytical application of PQQ-dependent glycerol dehydrogenase from Gluconobacter sp. 33 , 2005 .

[19]  Arne Torstensson,et al.  Electrocatalytic oxidation of reduced nicotinamide coenzymes by graphite electrodes modified with an adsorbed phenoxazinium salt, meldola blue , 1984 .

[20]  S. Dong,et al.  Functionalized inorganic–organic composite material derivated by sol–gel for construction of mediated amperometric hydrogen peroxide biosensor , 1999 .

[21]  Jean-Louis Marty,et al.  Chronoamperometric determination of d-lactate using screen-printed enzyme electrodes , 2001 .

[22]  Arne Torstensson,et al.  A kinetic study of the reaction between dihydronicotinamide adenine dinucleotide (NADH) and an electrode modified by adsorption of 1,2-benzophenoxazine-7-one , 1985 .

[23]  J. Kulys,et al.  The Development of New Analytical Systems Based on Biocatalysts , 1981 .

[24]  M. Zamin,et al.  Ion exchange of strontium and caesium into amorphous zirconium phosphates , 1997 .

[25]  M. D. Smith,et al.  Differential amperometric measurement of serum lactate dehydrogenase activity using Bindschedler's green. , 1974, Analytical Chemistry.

[26]  E. Csöregi,et al.  Glycerol Dehydrogenase Based Amperometric Biosensor for Monitoring of Glycerol in Alcoholic Beverages , 2003 .

[27]  Z. Galus Fundamentals of electrochemical analysis , 1976 .

[28]  B. Keita,et al.  Oxidation of NADH by oxometalates , 1994 .

[29]  L. Gorton,et al.  An amperometric glucose electrode based on carbon paste, chemically modified with glucose dehydrogenase, nicotinamide adenine dinucleotide, and a phenoxazine mediator, coated with a poly(ester sulfonic acid) cation exchanger , 1991 .