FPGA-Based Voltage and Current Dual Drive System for High Frame Rate Electrical Impedance Tomography

Electrical impedance tomography (EIT) is used to image the electrical property distribution of a tissue under test. An EIT system comprises complex hardware and software modules, which are typically designed for a specific application. Upgrading these modules is a time-consuming process, and requires rigorous testing to ensure proper functioning of new modules with the existing ones. To this end, we developed a modular and reconfigurable data acquisition (DAQ) system using National Instruments' (NI) hardware and software modules, which offer inherent compatibility over generations of hardware and software revisions. The system can be configured to use up to 32-channels. This EIT system can be used to interchangeably apply current or voltage signal, and measure the tissue response in a semi-parallel fashion. A novel signal averaging algorithm, and 512-point fast Fourier transform (FFT) computation block was implemented on the FPGA. FFT output bins were classified as signal or noise. Signal bins constitute a tissue's response to a pure or mixed tone signal. Signal bins' data can be used for traditional applications, as well as synchronous frequency-difference imaging. Noise bins were used to compute noise power on the FPGA. Noise power represents a metric of signal quality, and can be used to ensure proper tissue-electrode contact. Allocation of these computationally expensive tasks to the FPGA reduced the required bandwidth between PC, and the FPGA for high frame rate EIT. In 16-channel configuration, with a signal-averaging factor of 8, the DAQ frame rate at 100 kHz exceeded 110 frames s -1, and signal-to-noise ratio exceeded 90 dB across the spectrum. Reciprocity error was found to be for frequencies up to 1 MHz. Static imaging experiments were performed on a high-conductivity inclusion placed in a saline filled tank; the inclusion was clearly localized in the reconstructions obtained for both absolute current and voltage mode data.

[1]  David Isaacson,et al.  An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography. , 2008, International journal of control, automation, and systems.

[2]  Keith D. Paulsen,et al.  A Broadband High-Frequency Electrical Impedance Tomography System for Breast Imaging , 2008, IEEE Transactions on Biomedical Engineering.

[3]  G.J. Saulnier,et al.  ACT3: a high-speed, high-precision electrical impedance tomograph , 1991, IEEE Transactions on Biomedical Engineering.

[4]  Eung Je Woo,et al.  A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2 , 2011, Physiological measurement.

[5]  J. Rosell,et al.  Multi-frequency static imaging in electrical impedance tomography: Part 1 instrumentation requirements , 1995, Medical and Biological Engineering and Computing.

[6]  Ryan J Halter,et al.  Electrical properties of prostatic tissues: I. Single frequency admittivity properties. , 2009, The Journal of urology.

[7]  Ning Liu ACT4: A high-precision, multi-frequency electrical impedance tomograph , 2007 .

[8]  Ryan Halter,et al.  FPGA Based High Speed Data Acquisition System for Electrical Impedance Tomography. , 2013, Journal of physics. Conference series.

[9]  Zhenyu Guo,et al.  A review of electrical impedance techniques for breast cancer detection. , 2003, Medical engineering & physics.

[10]  Daniel J. Hawrysz,et al.  Three-dimensional, Bayesian image reconstruction from sparse and noisy data sets: Near-infrared fluorescence tomography , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[11]  William R B Lionheart,et al.  The Reconstruction Problem , 2017 .

[12]  Andy Adler,et al.  A Resistive Mesh Phantom for Assessing the Performance of EIT Systems , 2010, IEEE Transactions on Biomedical Engineering.

[13]  Eung Je Woo,et al.  Multi-frequency EIT system with radially symmetric architecture: KHU Mark1 , 2007, Physiological measurement.

[14]  Keith D. Paulsen,et al.  3D electric impedance tomography reconstruction on multi-core computing platforms , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  Wang Yan,et al.  Integrated Data Collection in Electrical Impedance Tomography , 2007 .

[16]  David S. Holder,et al.  Electrical Impedance Tomography : Methods, History and Applications , 2004 .

[17]  B.H. Brown,et al.  A real-time electrical impedance tomography system for clinical use-design and preliminary results , 1995, IEEE Transactions on Biomedical Engineering.

[18]  U. Faust,et al.  In vivo EIT electrode system with 32 interlaced active electrodes , 2006, Medical and Biological Engineering and Computing.

[19]  Andy Adler,et al.  Electrical impedance tomography system based on active electrodes , 2012, Physiological measurement.

[20]  Ryan Halter,et al.  Per Pattern-based Calibration Method for EIT Systems , 2014 .

[21]  Ryan J Halter,et al.  Electrical properties of prostatic tissues: II. Spectral admittivity properties. , 2009, The Journal of urology.

[22]  R H Smallwood,et al.  Mk3.5: a modular, multi-frequency successor to the Mk3a EIS/EIT system. , 2001, Physiological measurement.

[23]  Eung Je Woo,et al.  Multi-Frequency Electrical Impedance Tomography System , 2007 .

[24]  Alexander S Ross,et al.  Current source design for electrical impedance tomography. , 2003, Physiological measurement.

[25]  Keith D. Paulsen,et al.  A multichannel continuously selectable multifrequency electrical impedance spectroscopy measurement system , 2000, IEEE Transactions on Biomedical Engineering.

[26]  Richard H. Bayford,et al.  A comparison of techniques to optimize measurement of voltage changes in electrical impedance tomography by minimizing phase shift errors , 2002, IEEE Transactions on Medical Imaging.

[27]  Keith D. Paulsen,et al.  Using voltage sources as current drivers for electrical impedance tomography , 2002 .

[28]  H Griffiths A phantom for electrical impedance tomography. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[29]  Marko Vauhkonen,et al.  Suitability of a PXI platform for an electrical impedance tomography system , 2008 .

[30]  G Hahn,et al.  Systematic errors of EIT systems determined by easily-scalable resistive phantoms , 2008, Physiological measurement.