A model for harmonization of routine clinical chemistry results between clinical laboratories

Clinical chemistry laboratory results from different laboratories often show large between-laboratory variation due to factors such as differences in method principles, method applications, calibration procedures or the application of different instrument factor settings within the same calibration procedure. We have examined the possible use of common calibrators to reduce this variation. Three different calibrators were compared: A, freeze-dried preparations of pooled patients' serum samples, spiked to give three concentration levels; B, freeze-dried preparations of pooled patients' serum samples selected on the basis of elevated enzyme activities at three levels; C, a single calibrator consisting of frozen pooled serum samples. These calibrators were sent to 11 participating laboratories together with 14 fresh patients' serum samples. We report the variation of the results of 21 general clinical chemistry analytes obtained in the patients' serum samples before and after recalculation on the basis of the results of the calibrators. For most analytes the use of a multiple point linear regression calibration function is able to reduce the between-laboratory variation considerably from more than 30% (enzymes) to values well within the bias limits set by European quality specifications, when the necessary conditions are met. These conditions include the commutability of the calibrator(s) with fresh patients' material. For the enzymes, calibrator material originating from selectively pooled patients' samples appeared to be necessary, whereas for the substrates selectively pooled serum calibrators spiked with exogenous supplements may be used. For harmonization to be effective in practice, calibrators need to be stable over time and to carry assigned values set by certified reference laboratories, and the quality performance of participating laboratories should be appropriately monitored.

[1]  Christy Chuang-Stein,et al.  Summarizing Laboratory Data with Different Reference Ranges in Multi-Center Clinical Trials , 1992 .

[2]  F. Schiele,et al.  Usefulness of Reference Materials in Calibration of Enzyme Activities , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[3]  J. Hafkenscheid,et al.  Effects of temperature on measurement of aspartate aminotransferase and alanine aminotransferase in commercial control sera. , 1986, Clinical chemistry.

[4]  R. Jansen,et al.  Between-Country Comparability of Clinical Chemistry Results: An International Quality Assessment Survey of 17 Analytes in Six European Countries through Existing National Schemes , 1993, Annals of clinical biochemistry.

[5]  P. Demacker,et al.  Testing the accuracy of total cholesterol assays in an external quality-control program. Effect of adding sucrose to lyophilized control sera compared with use of fresh or frozen sera. , 1995, Clinical chemistry.

[6]  R T Jansen,et al.  Standards versus Standardised Methods in Enzyme Assay , 1983, Annals of clinical biochemistry.

[7]  P. H. Petersen,et al.  External quality assessment: currently used criteria for evaluating performance in European countries, and criteria for future harmonization. , 1996, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[8]  P. Crane,et al.  Interlaboratory standardization of enzyme results: the Richmond project. , 1986, Clinical Chemistry.

[9]  W. Withold,et al.  Storage of Serum or Whole Blood Samples? Effects of Time and Temperature on 22 Serum Analytes , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[10]  C Ricós,et al.  Desirable routine analytical goals for quantities assayed in serum. Discussion paper from the members of the external quality assessment (EQA) Working Group A on analytical goals in laboratory medicine. , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[11]  R. Jansen,et al.  Minimizing interlaboratory variation in routine assays of serum cholesterol through the use of serum calibrators. , 1986, Clinical chemistry.

[12]  C G Fraser,et al.  Proposed quality specifications for the imprecision and inaccuracy of analytical systems for clinical chemistry. , 1992, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[13]  M Hørder,et al.  Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area. , 1988, Scandinavian journal of clinical and laboratory investigation.

[14]  G. Steen,et al.  Multicenter harmonization of common enzyme results by fresh patient-pool sera. , 1998, Clinical chemistry.