A Novel Calibration Method for Object Plane Tilt Angle Measurement in Microscope System

A novel calibration method is proposed to measure object plane tilt angle in microscope system with small-depth-field. The proposed method is constructed by a space model about calibration board and the surface of image. Only a rotating disk, a goniometer and a calibration board with some features are needed, the tilt angle between the object plane and image plane and their geometric relationship can be estimated by the space model. Compared with some classical calibration methods with expensive equipment, the proposed method is easy to be implemented with relative cheap equipments. Moreover, it has been proved that the proposed method is quite efficient through experimental verification. It can also contribute to three dimensional applications in computer vision of microsystems.

[1]  Weiming Dong,et al.  Segment-tree based cost aggregation for stereo matching with enhanced segmentation advantage , 2013, 2017 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[2]  Matt Adcock,et al.  Virtual 3D Models of Insects for Accelerated Quarantine Control , 2013, 2013 IEEE International Conference on Computer Vision Workshops.

[3]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[4]  Mei Yu,et al.  A depth estimation method based on geometric transformation for stereo light microscope. , 2014, Bio-medical materials and engineering.

[5]  Mehdi Ammi,et al.  Automatic Camera-Based Microscope Calibration for a Telemicromanipulation System Using a Virtual Pattern , 2009, IEEE Transactions on Robotics.

[6]  Janne Heikkilä,et al.  A four-step camera calibration procedure with implicit image correction , 1997, Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition.

[7]  Surjya K. Pal,et al.  Application of digital image processing in tool condition monitoring: A review , 2013 .

[8]  Qingxiong Yang,et al.  A non-local cost aggregation method for stereo matching , 2012, 2012 IEEE Conference on Computer Vision and Pattern Recognition.

[9]  B. Peuchot Camera virtual equivalent model 0.01 pixel detectors. , 1993, Computerized Medical Imaging and Graphics.

[10]  Roger Y. Tsai,et al.  A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..

[11]  Maurizio Muzzupappa,et al.  3D reconstruction of small sized objects from a sequence of multi-focused images , 2014 .

[12]  Fengzhou Fang,et al.  Manufacturing and measurement of freeform optics , 2013 .

[13]  Bo Wang,et al.  The research of medical microscopic image mosaic based on the algorithm of surf , 2013, 2013 10th International Computer Conference on Wavelet Active Media Technology and Information Processing (ICCWAMTIP).

[14]  Bo Dong,et al.  Model-based micro profile measurement using multi-focused images for micro gear assembly , 2010, 2010 IEEE 5th International Conference on Nano/Micro Engineered and Molecular Systems.