A rapid approach for quantitative magnetization transfer imaging in thigh muscles using the pulsed saturation method.

Quantitative magnetization transfer (qMT) imaging in skeletal muscle may be confounded by intramuscular adipose components, low signal-to-noise ratios (SNRs), and voluntary and involuntary motion artifacts. Collectively, these issues could create bias and error in parameter fitting. In this study, technical considerations related to these factors were systematically investigated, and solutions were proposed. First, numerical simulations indicate that the presence of an additional fat component significantly underestimates the pool size ratio (F). Therefore, fat-signal suppression (or water-selective excitation) is recommended for qMT imaging of skeletal muscle. Second, to minimize the effect of motion and muscle contraction artifacts in datasets collected with a conventional 14-point sampling scheme, a rapid two-parameter model was adapted from previous studies in the brain and spinal cord. The consecutive pair of sampling points with highest accuracy and precision for estimating F was determined with numerical simulations. Its performance with respect to SNR and incorrect parameter assumptions was systematically evaluated. QMT data fitting was performed in healthy control subjects and polymyositis patients, using both the two- and five-parameter models. The experimental results were consistent with the predictions from the numerical simulations. These data support the use of the two-parameter modeling approach for qMT imaging of skeletal muscle as a means to reduce total imaging time and/or permit additional signal averaging.

[1]  John C Gore,et al.  Quantitative magnetization transfer imaging via selective inversion recovery with short repetition times , 2007, Magnetic resonance in medicine.

[2]  S. Ropele,et al.  Fast Bound Pool Fraction Mapping Using Stimulated Echoes , 2011, Magnetic resonance in medicine.

[3]  Chun Yuan,et al.  Fast bound pool fraction imaging of the in vivo rat brain: Association with myelin content and validation in the C6 glioma model , 2011, NeuroImage.

[4]  D. Gochberg,et al.  Transverse relaxation and magnetization transfer in skeletal muscle: Effect of pH , 2009, Magnetic resonance in medicine.

[5]  Vasily L Yarnykh,et al.  Pulsed Z‐spectroscopic imaging of cross‐relaxation parameters in tissues for human MRI: Theory and clinical applications , 2002, Magnetic resonance in medicine.

[6]  A quantitative study of magnetization transfer in MAGIC gels. , 2003, Physics in medicine and biology.

[7]  Daniel C Alexander,et al.  Optimal acquisition schemes for in vivo quantitative magnetization transfer MRI , 2006, Magnetic resonance in medicine.

[8]  G. B. Pike,et al.  Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI , 2001, Magnetic resonance in medicine.

[9]  G H Glover,et al.  An extended two‐point dixon algorithm for calculating separate water, fat, and B0 images , 1997, Magnetic resonance in medicine.

[10]  G. Barker,et al.  Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times. , 2002, Magnetic resonance imaging.

[11]  Vasily L Yarnykh,et al.  Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency field , 2007, Magnetic resonance in medicine.

[12]  J. Gore,et al.  Quantitative studies of magnetization transfer by selective excitation and T1 recovery , 1997, Magnetic resonance in medicine.

[13]  Chun Yuan,et al.  Cross-relaxation imaging reveals detailed anatomy of white matter fiber tracts in the human brain , 2004, NeuroImage.

[14]  T. Yankeelov,et al.  Multi‐parametric MRI characterization of inflammation in murine skeletal muscle , 2014, NMR in biomedicine.

[15]  Ke Li,et al.  Quantitative magnetization transfer imaging of human brain at 7T , 2013, NeuroImage.

[16]  Shu-Wei Sun,et al.  Quantitative magnetization transfer measured pool‐size ratio reflects optic nerve myelin content in ex vivo mice , 2009, Magnetic resonance in medicine.

[17]  R M Henkelman,et al.  A flexible magnetization transfer line shape derived from tissue experimental data , 1997, Magnetic resonance in medicine.

[18]  G. Pike,et al.  Quantitative interpretation of magnetization transfer in spoiled gradient echo MRI sequences. , 2000, Journal of magnetic resonance.

[19]  Vaibhav A. Janve,et al.  Optimized inversion recovery sequences for quantitative T1 and magnetization transfer imaging , 2010, Magnetic resonance in medicine.

[20]  Richard D. Dortch,et al.  Rapid, high-resolution quantitative magnetization transfer MRI of the human spinal cord , 2014, NeuroImage.

[21]  David L. Thomas,et al.  Quantitative Magnetization Transfer in In Vivo Healthy Human Skeletal Muscle at 3 T , 2010, Magnetic resonance in medicine.

[22]  Gareth J. Barker,et al.  A comparison between equations describing in vivo MT: The effects of noise and sequence parameters , 2008, Journal of magnetic resonance.

[23]  Vasily L Yarnykh,et al.  Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement , 2012, Magnetic resonance in medicine.

[24]  Theodore F. Towse,et al.  Multi‐parametric MRI characterization of healthy human thigh muscles at 3.0 T – relaxation, magnetization transfer, fat/water, and diffusion tensor imaging , 2014, NMR in biomedicine.

[25]  S. Singer,et al.  Fat‐free MRI based on magnetization exchange , 2010, Magnetic resonance in medicine.

[26]  R M Henkelman,et al.  Quantitative interpretation of magnetization transfer , 1993, Magnetic resonance in medicine.

[27]  H. Moser,et al.  Quantitative magnetization transfer characteristics of the human cervical spinal cord in vivo: Application to Adrenomyeloneuropathy , 2009, Magnetic resonance in medicine.