Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCT.
暂无分享,去创建一个
[1] Jie Tang,et al. Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms , 2009, Physics in medicine and biology.
[2] M. S. Kaplan,et al. Differential attenuation method for simultaneous estimation of activity and attenuation in multiemission single photon emission computed tomography. , 1999, Medical physics.
[3] Jitendra Malik,et al. Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..
[4] Predrag Sukovic,et al. Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography , 2000, IEEE Transactions on Medical Imaging.
[5] F. Hermansen,et al. Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior , 2004, Physics in medicine and biology.
[6] E. Sidky,et al. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.
[7] Zhengrong Liang,et al. Dose reduction for kilovotage cone-beam computed tomography in radiation therapy. , 2008, Physics in medicine and biology.
[8] Ken D. Sauer,et al. A unified approach to statistical tomography using coordinate descent optimization , 1996, IEEE Trans. Image Process..
[9] Zhengrong Liang,et al. An experimental study on the noise properties of x-ray CT sinogram data in Radon space , 2008, Physics in medicine and biology.
[10] Jeffrey A. Fessler. Penalized weighted least-squares image reconstruction for positron emission tomography , 1994, IEEE Trans. Medical Imaging.
[11] L. Xing,et al. Iterative image reconstruction for CBCT using edge-preserving prior. , 2008, Medical physics.
[12] J. Wong,et al. Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.
[13] Adam Wunderlich,et al. Image covariance and lesion detectability in direct fan-beam x-ray computed tomography , 2008, Physics in medicine and biology.
[14] Zhengrong Liang,et al. Recent development of Low-dose X-ray Cone-beam computed tomography , 2010 .
[15] Jeffrey A. Fessler,et al. Statistical image reconstruction for polyenergetic X-ray computed tomography , 2002, IEEE Transactions on Medical Imaging.
[16] R. Siddon. Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.
[17] Zhengrong Liang,et al. A fast ray-tracing technique for TCT and ECT studies , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).
[18] Richard M. Leahy,et al. Covariance approximation for fast and accurate computation of channelized Hotelling observer statistics , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).
[19] David A Jaffray,et al. Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. , 2006, Medical physics.
[20] M. Persson,et al. Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography , 2001, Physics in medicine and biology.
[21] B. Movsas,et al. Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer , 2007, Physics in medicine and biology.
[22] W. Kalender,et al. Comparison of ring artifact correction methods for flat-detector CT , 2009, Physics in medicine and biology.
[23] David L Donoho,et al. Compressed sensing , 2006, IEEE Transactions on Information Theory.
[24] Hengyong Yu,et al. Compressed sensing based interior tomography , 2009, Physics in medicine and biology.
[25] Hongbing Lu,et al. Nonlinear sinogram smoothing for low-dose X-ray CT , 2004 .
[26] Jean-Baptiste Thibault,et al. A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.
[27] Ken D. Sauer,et al. A local update strategy for iterative reconstruction from projections , 1993, IEEE Trans. Signal Process..
[28] Steve B. Jiang,et al. GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation , 2010 .