Preclinical Evaluation of a Hollow Fiber Silicone Membrane Oxygenator for Extracorporeal Membrane Oxygenator Application
暂无分享,去创建一个
J. Linneweber | Y. Nosé | K. Nakata | T. Takano | S. Schulte-Eistrup | S. Kawahito | T. Maeda | K. Nonaka | S. Murabayashi | M. Yoshikawa | A. Iwasaki | J. Kuwana | Koshiro Sato
[1] Y Nosé,et al. Hemolysis in different centrifugal pumps. , 2008, Artificial organs.
[2] J. Hayashi,et al. Biocompatibility of a silicone-coated polypropylene hollow fiber oxygenator in an in vitro model. , 1999, The Annals of thoracic surgery.
[3] Y Nosé,et al. Development of a silicone hollow fiber membrane oxygenator for ECMO application. , 1998, ASAIO journal.
[4] Y. Shomura,et al. Clinical Evaluation of a Silicone Coated Hollow Fiber Oxygenator , 1997, ASAIO journal.
[5] Y. Niimi,et al. Protein Adsorption and Platelet Adhesion on the Surface of an Oxygenator Membrane , 1997, ASAIO journal.
[6] Y. Nosé,et al. COMPARISON OF PROTEIN ADSORPTION AND PLATELET ADHESION ON THE SURFACE OF OXYGENATOR MEMBRANES , 1997 .
[7] Y Nosé,et al. Effect of surface roughness on hemolysis in a centrifugal blood pump. , 1996, ASAIO journal.
[8] M. Sefton,et al. Platelet activation in whole blood by artificial surfaces: identification of platelet-derived microparticles and activated platelet binding to leukocytes as material-induced activation events. , 1995, The Journal of laboratory and clinical medicine.
[9] M. Ziegler,et al. The significant relationship between platelet count and haemorrhagic complications on ECMO , 1994, Perfusion.
[10] R H Bartlett,et al. Plasma leakage through microporous membranes. Role of phospholipids. , 1992, ASAIO journal.
[11] V. Videm,et al. Biocompatibility of extracorporeal circulation. In vitro comparison of heparin-coated and uncoated oxygenator circuits. , 1991, The Journal of thoracic and cardiovascular surgery.
[12] A. Kashefi,et al. Technical aspects of plasma leakage prevention in microporous capillary membrane oxygenators. , 1989, ASAIO transactions.
[13] T. Morimoto. [Development of a hollow fiber membrane oxygenator for long term extracorporeal membrane oxygenation]. , 1982, [Zasshi] [Journal]. Nihon Kyobu Geka Gakkai.
[14] C R Vocelka,et al. An in vitro protocol for evaluation and comparison of membrane oxygenators. , 1993, The journal of extra-corporeal technology.
[15] W. Zapol,et al. Extended term (to 16 days) partial extracorporeal blood gas exchange with the spiral membrane lung in unanesthetized lambs. , 1971, Transactions - American Society for Artificial Internal Organs.