A Tracking Compton-Scattering Imaging System for Hadron Therapy Monitoring

Hadron therapy for, e.g., cancer treatment requires an accurate dose deposition (total amount and location). As a consequence, monitoring is crucial for the success of the treatment. Currently employed PET imaging systems are not able to provide information about the deposed dose fast enough to allow stopping the therapy in case of a discordance with the treatment plan. We are currently investigating an imaging system based on a combined Compton scattering and pair creation camera capable of imaging gamma rays up to 50 MeV. The camera would be able to measure the complete spectrum of emitted gamma rays during the therapy session. We have performed Monte Carlo simulations for three different proton beam energies in a typical hadron therapy scenario. They show that the location of the gamma-ray distribution decay and the falloff region of the deposed dose are related. The reconstructed images prove that the proposed system could provide the required imaging and dose location capabilities.

[1]  N. Clinthorne,et al.  Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Images , 2000 .

[2]  Robert Andritschke,et al.  MEGAlib – The Medium Energy Gamma-ray Astronomy Library , 2006 .

[3]  Katia Parodi,et al.  In-beam PET measurements of β+ radioactivity induced by proton beams , 2002 .

[4]  A. Kubo,et al.  Development of Electron Tracking Compton Camera using micro pixel gas chamber for medical imaging , 2007 .

[5]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[6]  Chan Hyeong Kim,et al.  Prompt gamma measurements for locating the dose falloff region in the proton therapy , 2006 .

[7]  L. J. Thomas,et al.  Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[8]  A. Zoglauer First light for the next generation of compton and pair telescopes : development of new techniques for the data analysis of combined compton and pair telescopes and their application to the MEGA prototype , 2005 .

[9]  R. Marc Kippen,et al.  The GEANT low energy Compton scattering (GLECS) package for use in simulating advanced Compton telescopes , 2004 .

[10]  A. Zoglauer,et al.  Application of neural networks to the identification of the compton interaction sequence in compton imagers , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[11]  Georg Weidenspointner,et al.  MEGAlib: simulation and data analysis for low-to-medium-energy gamma-ray telescopes , 2008, Astronomical Telescopes + Instrumentation.

[12]  T. Tanimori,et al.  MeV Gamma-Ray Imaging Detector with micro-TPC , 2003, astro-ph/0403518.

[13]  Jeffrey A. Fessler,et al.  List-mode maximum likelihood reconstruction of Compton scatter camera images in nuclear medicine , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[14]  Robert Andritschke,et al.  A bayesian-based method for particle track identification in low-energy pair-creation telescopes , 2007 .

[15]  Tsutomu Nagayoshi,et al.  MeV Gamma-Ray Imaging Detector with micro-TPC , 2004 .