Radiofrequency ablation using a new type of internally cooled electrode with an adjustable active tip: an experimental study in ex vivo bovine and in vivo porcine livers.

PURPOSE The aims of this study were to evaluate the performance of radiofrequency (RF) ablation using a new type of internally cooled RF electrode with an adjustable active tip in an ex vivo bovine liver model and to determine if adjustment of the active tip length makes a significant difference in the size of ablation zone in an in vivo porcine liver model. MATERIALS AND METHODS We performed ex vivo experiments by producing 100 RF ablation zones in 40 extracted bovine livers using a new type of RF electrode that had an adjustable active tip (adjustable electrode) (n = 50) and a conventional internally cooled electrode (conventional electrode) (n = 50). We also performed an in vivo study with the induction of 30 RF ablation zones in ten living porcine livers using the adjustable electrode with 2 cm (n = 15) and 3 cm (n = 15) active tip adjustments. The size (three perpendicular diameters), volume and ratio of the two axes of the ablation zone were macroscopically evaluated and were compared. RESULTS For the ex vivo study using a 2 cm and 3 cm active tip, there was no significant difference in ablation performance between the use of conventional and adjustable electrodes. For the use of the conventional and adjustable electrodes with 2 cm active tip, respectively, the volume was 10.75 ± 3.43 cm(3) versus 10.64 ± 3.25 cm(3) and the ratio of the two axes was 1.24 ± 0.16 versus 1.30 ± 0.17; p > 0.05. For the use of the conventional and adjustable electrodes with 3 cm active tip, respectively, the volume was 21.17 ± 4.09 cm(3) versus 21.48 ± 3.51 cm(3) and the ratio of the two axes was 1.28 ± 0.12 versus 1.28 ± 0.07; p > 0.05. For the in vivo study using the adjustable electrode, the ablation volume with the 2 cm adjustment was significantly smaller as compared to the 3 cm adjustment (5.29 ± 2.22 cm(3) versus 13.44 ± 4.25 cm(3); p < 0.05) with no statistical difference for the ratio of the two axes (1.44 ± 0.22 versus 1.49 ± 0.24; p > 0.05). CONCLUSION Using a new type of internally cooled RF electrode, we could induce different volumes of the RF ablation zone by means of adjusting the length of the exposed active tip, where performance was similar to the use of a conventional internally cooled RF electrode.

[1]  M. Choi,et al.  Percutaneous radiofrequency ablation for early-stage hepatocellular carcinoma as a first-line treatment: long-term results and prognostic factors in a large single-institution series , 2007, European Radiology.

[2]  S. Mulier,et al.  A novel “cooled-wet” electrode for radiofrequency ablation , 2000, European Radiology.

[3]  K. L. Mittal,et al.  Polyimides: Fundamentals and Applications , 1996 .

[4]  G S Gazelle,et al.  Percutaneous radiofrequency tissue ablation: optimization of pulsed-radiofrequency technique to increase coagulation necrosis. , 1999, Journal of vascular and interventional radiology : JVIR.

[5]  D. Choi,et al.  Radiofrequency ablation of the liver abutting stomach: in vivo comparison of gastric injury before and after intragastric saline administration in a porcine model. , 2009, European journal of radiology.

[6]  T. Lorentzen,et al.  A cooled needle electrode for radiofrequency tissue ablation: thermodynamic aspects of improved performance compared with conventional needle design. , 1996, Academic radiology.

[7]  A Roche,et al.  Radiofrequency liver ablation: experimental comparative study of water-cooled versus expandable systems. , 2001, AJR. American journal of roentgenology.

[8]  L Solbiati,et al.  Small hepatocellular carcinoma: treatment with radio-frequency ablation versus ethanol injection. , 1999, Radiology.

[9]  Zongli Zhang,et al.  Chemoembolization combined with radiofrequency ablation for patients with hepatocellular carcinoma larger than 3 cm: a randomized controlled trial. , 2008, JAMA.

[10]  Christopher L Brace,et al.  Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results. , 2006, Radiology.

[11]  J. McGahan,et al.  Hepatic ablation with use of radio-frequency electrocautery in the animal model. , 1992, Journal of vascular and interventional radiology : JVIR.

[12]  Efficacy and safety of radiofrequency ablation of hepatocellular carcinoma in the hepatic dome with the CT-guided extrathoracic transhepatic approach. , 2006, European journal of radiology.

[13]  L Solbiati,et al.  Hepatic metastases: percutaneous radio-frequency ablation with cooled-tip electrodes. , 1997, Radiology.

[14]  Y. Ni,et al.  A comparative study on validation of a novel cooled-wet electrode for radiofrequency liver ablation. , 2000, Investigative radiology.

[15]  B. Choi,et al.  Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system , 2005, European Radiology.

[16]  S. Fan,et al.  Porcine liver: morphologic characteristics and cell viability at experimental radiofrequency ablation with internally cooled electrodes. , 2005, Radiology.

[17]  W R Lees,et al.  Minimally invasive treatment of malignant hepatic tumors: at the threshold of a major breakthrough. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[18]  Dongil Choi,et al.  CT findings after radiofrequency ablation in rabbit livers: comparison of internally cooled electrodes, perfusion electrodes, and internally cooled perfusion electrodes. , 2007, Journal of vascular and interventional radiology : JVIR.