BACKGROUND
Conservative breast resection with subsequent sentinel lymph node biopsy (SNB) is an increasingly popular initial approach for the treatment of breast cancer due to decreased invasiveness. SNB is a shorter procedure with fewer side effects than more substantial surgical procedures, but it sometimes fails to identify metastatic disease. Therefore, a highly sensitive and convenient method is needed to identify sentinel lymph nodes (SLN) with a high probability of containing disease in SNB. We compared the combination of radioisotope or dye with a fluorescence compound to analyze lymph flow to identify targets for SNB.
MATERIALS AND METHODS
We examined patients with breast cancer lacking metastases in the axillary lymph node (ALN). Two methods for targeted SNB were developed: (1) Indocyanine Green (ICG) and Patent blue were injected into the skin overlying the tumor and sub-areolar region just before the surgical procedure. (2) ICG and radiocolloid were injected into the skin overlying the tumor and sub-areolar region. The draining fluorescent lymphatic duct was visualized using a Photodynamic Eye (PDE). We removed the SLNs that were identified by the dye and fluorescence imaging methods. Method 1 was applied to 113 patients undergoing SNB, and 29 patients were treated with Method 2. In our study, patients were grouped by lymph flow into two types: Type C demonstrated convergence to one lymph duct. Type S demonstrated separate lymph ducts.
RESULTS
Using the fluorescence imaging method, 99.3% of SLNs were identified, and 3.8 SLNs per patient were seen. The SLN identification rates for Patent blue dye and radiocolloid were 92.9% and 100%, respectively, while 1.9 and 2.0 SLNs per patient, respectively, were seen with these methods. We classified two types of lymph flow based on the pattern of lymphatic drainage. Type C converged to a single lymph duct, while Type S drained to separate ducts. Type S lymph drainage was seen in 29/142 patients (20.4%), and Type C drainage was found in 113/141 patients (79.6%). Of the patients with Type S drainage, there were 4.1 SLNs per patient, but only 3.4 SLNs per patient were seen in individuals with Type C drainage. Forty cases had metastases found in the ALNs, and five of these cases were dye-negative and fluorescence-positive. Among these cases, the average number of SLNs identified was one.
CONCLUSION
The combination of fluorescence with a visible dye is a highly sensitive method for SLN identification. When SNB is guided by only the dye method, there is a risk of missing appropriate SLNs in patients with Type S lymph drainage or weak dye staining. The use of a fluorescence method together with dye could increase sensitivity of detection in these cases. Furthermore, fluorescent methods are ideal for hospitals that cannot use conventional radioactive measures.
[1]
I Nakajima,et al.
An intraoperative fluorescent imaging system in organ transplantation.
,
2004,
Transplantation proceedings.
[2]
D. Taggart,et al.
Does off-pump total arterial grafting increase the incidence of intraoperative graft failure?
,
2004,
The Journal of thoracic and cardiovascular surgery.
[3]
G. Ian Taylor,et al.
Annals of Surgical Oncology 15(3):863–871 DOI: 10.1245/s10434-007-9709-9 The Lymphatic Anatomy of the Breast and its Implications for Sentinel Lymph Node Biopsy: A Human Cadaver Study
,
2022
.
[4]
G. Farshid,et al.
Removal of two sentinel nodes accurately stages the axilla in breast cancer
,
2003,
The British journal of surgery.
[5]
L. Cohn,et al.
Intraoperative identification of esophageal sentinel lymph nodes with near-infrared fluorescence imaging.
,
2005,
The Journal of thoracic and cardiovascular surgery.
[6]
S. Noguchi,et al.
Sentinel Node Biopsy Guided by Indocyanin Green Dye in Breast Cancer Patients
,
1999
.
[7]
Mitsuharu Miwa,et al.
Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
,
2005,
Breast cancer.
[8]
P. Vogt,et al.
Novadaq Spy Intraoperative Imaging System--current status.
,
2003,
The Thoracic and cardiovascular surgeon.
[9]
Aya Nakagawa,et al.
Intraoperative identification of sentinel lymph nodes by near-infrared fluorescence imaging in patients with breast cancer.
,
2008,
American journal of surgery.
[10]
P B Cerrito,et al.
Sentinel lymph node biopsy for breast cancer: a suitable alternative to routine axillary dissection in multi-institutional practice when optimal technique is used.
,
2000,
Journal of clinical oncology : official journal of the American Society of Clinical Oncology.
[11]
M. Noguchi,et al.
A multicenter validation study of sentinel lymph node biopsy by the Japanese Breast Cancer Society
,
2000,
Breast Cancer Research and Treatment.
[12]
R. Moonka,et al.
Criteria for establishing the adequacy of a sentinel lymphadenectomy.
,
2004,
American journal of surgery.