Thermal comfort conditions near highly glazed façades : an experimental and simulation study

There is a current trend of designing new commercial buildings with large glazed facade areas. Maintaining comfort in the perimeter zones of these buildings is difficult due to their exposure to solar radiation and cold outdoor air temperature. Designing these buildings with high-performance fenestration systems, however, can improve energy performance, provide a high-quality thermal and visual environment, and reduce thermal loads. This study presents an experimental and simulation study of thermal comfort conditions of a perimeter zone office with a glass facade and solar shading device. The study investigates the impact of climate, glazing type, and shading device properties on thermal comfort conditions. The objective of this study is to determine the facade properties that will provide a comfortable indoor environment without the need for secondary perimeter heating. Experimental measurements were taken in an office equipped with two different shading devices: venetian blind and roller shade. The thermal environment was measured with thermocouples, an indoor climate analyzer, and thermal comfort meter. For the simulation study, a one-dimensional transient thermal simulation model of a typical glazed perimeter zone office and a transient two-node thermal comfort model were developed. The impact of solar radiation and shading device properties on thermal comfort was also quantified. Simulation results were compared with experimental measurements. The impact of diffuser location for primary heating supply on indoor airflow and comfort is also investigated using computational fluid dynamics software and it is shown that good comfort is achieved without the presence of perimeter heating.

[1]  Fred Bauman,et al.  Verification of BLAST by Comparison With Measurements of a Solar-Dominated Test Cell and a Thermally Massive Building , 1981 .

[2]  Andreas Fieber Building Integration of Solar Energy. A Multifunctional Approach , 2005 .

[3]  Ken Parsons,et al.  Human Thermal Environments: The Effects of Hot, Moderate, and Cold Environments on Human Health, Comfort and Performance , 1999 .

[4]  G. Cannistraro,et al.  Algorithms for the calculation of the view factors between human body and rectangular surfaces in parallelepiped environments , 1992 .

[5]  M Janak,et al.  Assessing the overall performance of advanced glazing systems , 1998 .

[6]  Ingvar Holmér,et al.  Solar heat load on man , 1993, International journal of biometeorology.

[7]  Hui Zhang,et al.  Window performance for human thermal comfort , 2006 .

[8]  J. L. M. Hensen,et al.  Literature review on thermal comfort in transient conditions , 1990 .

[9]  S. Chaiyapinunt,et al.  Performance rating of glass windows and glass windows with films in aspect of thermal comfort and heat transmission , 2005 .

[10]  J Toftum,et al.  Human projected area factors for detailed direct and diffuse solar radiation analysis , 2004, International journal of biometeorology.

[11]  G. Cannistraro,et al.  Algorithms for the calculation of the mean projected area factors of seated and standing persons , 1991 .

[12]  A. P. Gagge,et al.  An Effective Temperature Scale Based on a Simple Model of Human Physiological Regulatiry Response , 1972 .

[13]  P. Höppe Indoor climate , 2005, Experientia.

[14]  N. B. Hutcheon,et al.  Building Science for a Cold Climate , 1984 .

[15]  Athanassios Tzempelikos A methodology for detailed calculation of illuminance levels and light dimming factors in a room with motorized blinds integrated in an advanced window , 2001 .

[16]  W. A. Hawthorne,et al.  The impact of glazing selection on residential duct design and comfort , 2000 .

[17]  A. Hwang [Thermal comfort]. , 1990, Taehan kanho. The Korean nurse.

[18]  Radu Zmeureanu,et al.  Thermally acceptable temperature drifts can reduce the energy consumption for cooling in office buildings , 1992 .

[19]  L. Berglund,et al.  A standard predictive index of human response to the thermal environment , 1986 .

[20]  Th. Frank,et al.  Analysis of Thermal Comfort Near Cold Vertical Surfaces by Means of Computational Fluid Dynamics , 2004 .

[21]  H. Nilsson,et al.  Absorption of solar radiation by an ellipsoid sensor simulated the human body. , 1998, Applied human science : journal of physiological anthropology.

[22]  John Carmody,et al.  Window Systems for High-Performance Buildings , 2004 .

[23]  P. Fanger,et al.  Air turbulence and sensation of draught , 1988 .

[24]  Ken Parsons,et al.  The effects of solar radiation on thermal comfort , 2006, International journal of biometeorology.

[25]  C. Huizenga,et al.  Thermal sensation and comfort in transient non-uniform thermal environments , 2004, European Journal of Applied Physiology.

[26]  S. Iliescu,et al.  Radiation from cold or warm windows: computer model development and experimental validation , 2003 .

[27]  MA Humphreys,et al.  AN ANALYSIS OF SOME SUBJECTIVE ASSESSMENTS OF INDOOR AIR-QUALITY IN FIVE EUROPEAN COUNTRIES , 2002 .

[28]  G. Rizzo,et al.  The calculation of the mean radiant temperature of a subject exposed to the solar radiation—a generalised algorithm , 2005 .

[29]  J. Timusk,et al.  Building science for a cold climate , 1984 .

[30]  J. Michalsky,et al.  Modeling daylight availability and irradiance components from direct and global irradiance , 1990 .

[31]  Andreas K. Athienitis,et al.  Simulation of façade and envelope design options for a new institutional building , 2007 .

[32]  G. Augenbroe,et al.  DAYLIGHTING OPTIMIZATION IN SMART FAÇADE SYSTEMS , 2003 .

[33]  Per Heiselberg,et al.  Energy-Efficient Measures to Avoid Downdraft from Large Glazed Facades , 1996 .

[34]  Athanassios Tzempelikos A methodology for integrated daylighting and thermal analysis of buildings , 2005 .

[35]  Bahram Moshfegh,et al.  Experimental investigation of downdraught from well-insulated windows , 2002 .

[36]  Harris Poirazis,et al.  Single Skin Glazed Office Buildings - Energy Use and Indoor Climate Simulations , 2005 .

[37]  Hua Ge,et al.  Experimental investigation of cold draft induced by two different types of glazing panels in metal curtain walls , 2004 .

[38]  David Naylor,et al.  Heat Transfer From an Isothermal Vertical Surface With Adjacent Heated Horizontal Louvers: Numerical Analysis , 2002 .

[39]  Michael A. Humphreys,et al.  ADAPTIVE THERMAL COMFORT AND SUSTAINABLE THERMAL STANDARDS FOR BUILDINGS , 2002 .

[40]  G. Achard,et al.  SIMULATION OF VISUAL AND THERMAL COMFORT RELATED TO DAYLIGHTING AND SOLAR RADIATION IN OFFICE BUILDINGS , 1997 .

[41]  Hidayat Shahid,et al.  Energy performance assessment of a window with a horizontal Venetian blind , 2005 .

[42]  A. Athienitis,et al.  The impact of shading design and control on building cooling and lighting demand , 2007 .

[43]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[44]  Viktor Dorer,et al.  Must cold air down draughts be compensated when using highly insulating windows , 2001 .

[45]  Michel Cabanac,et al.  Pleasure and joy, and their role in human life , 1999 .

[46]  Tilmann E. Kuhn,et al.  Evaluation of overheating protection with sun-shading systems , 2001 .