Two-dimensional echocardiographic imaging: in vitro comparison of conventional and dynamically focused annular array transducers.

Quantitative two-dimensional echocardiography has been adversely affected by a tendency for underestimation of cross-sectional areas of cardiac chambers, a difficulty that might be ameliorated by recent advances in imaging technology. To determine if this were so, we measured echocardiographic cross-sectional areas of 25 formalin-fixed animal left ventricular (LV) sections in vitro using conventional 13 mm and 15 mm diameter fixed-focused single element transducers, and a 15 mm diameter dynamically focused annular array transducer at 3 different distances between myocardial slice and transducer (2 cm, 6 cm and 10 cm) and compared the 2-dimensional echocardiographic areas to the corresponding anatomic cross-sectional areas of the same hearts. LV total and cavity area were measured by computer assisted planimetry of videotaped echo images, performed blinded to the transducer used, and photographed anatomic slices; LV myocardial area was derived by subtraction. Comparison of two-dimensional echocardiographic total, myocardial, and cavity areas with corresponding anatomic measurements showed excellent correlation for each transducer at all depths (r = 0.97 to 0.98 for total area; r = 0.98 to 0.99 for cavity area; r = 0.93 to 0.97 for myocardial area). For total and myocardial cross-sectional areas, the slope of the relation between echographic and anatomic areas did not differ significantly from unity, but for LV cavity area this was achieved only by the dynamically focused transducer. In contrast, the conventional 13 mm transducer significantly underestimated larger LV cavity areas in both the near and middle fields (slopes = 0.90 and 0.91, respectively) and the 15 mm transducer yielded slopes from 0.86 to 0.91 in all fields.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  P. Guéret,et al.  Quantitative two dimensional echocardiography during bicycle exercise in normal subjects. , 1981, The American journal of cardiology.

[2]  N Reichek,et al.  Quantitation of Human Left Ventricular Mass and Volume by Two‐dimensional Echocardiography: In Vitro Anatomic Validation , 1981, Circulation.

[3]  R. C. Scott,et al.  Observations on the Assessment of Cardiac Hypertrophy Utilizing a Chamber Partition Technique , 1966, Circulation.

[4]  Randolph P. Martin,et al.  Reliability and reproducibility of two dimensional echocardiograph measurement of the stenotic mitral valve orifice area. , 1979, The American journal of cardiology.

[5]  S. Glagov,et al.  CONTROLLED PRESSURE FIXATION APPARATUS FOR HEARTS. , 1963, Archives of pathology.

[6]  E. Corday,et al.  Assessment of quantitative methods for 2-dimensional echocardiography. , 1983, The American journal of cardiology.

[7]  L H Oliver,et al.  Reproducibility of left ventricular area and volume measurements using a computer endocardial edge-detection algorithm in normal subjects. , 1985, The American journal of cardiology.

[8]  J. Hestenes,et al.  Cross‐sectional Echocardiography 1. Analysis of Mathematic Models for Quantifying Mass of the Left Ventricle in Dogs , 1979, Circulation.

[9]  A. Weyman Cross-sectional echocardiography , 1982 .

[10]  P. Guéret,et al.  Two‐dimensional Echocardiographic Quantitation of Left Ventricular Volumes and Ejection Fraction: Importance of Accounting for Dyssynergy in Short‐axis Reconstruction Models , 1980, Circulation.

[11]  A. Shoukas,et al.  Accurate Volume Determination in the Isolated Ejecting Canine Left Ventricle by Two-dimensional Echocardiography , 1979, Circulation.

[12]  N. Reichek,et al.  Two dimensional echographic imaging of the left ventricle: comparison of mechanical and phased array systems in vitro. , 1981, The American journal of cardiology.

[13]  S. M. Collins,et al.  Computer-assisted edge detection in two-dimensional echocardiography: comparison with anatomic data. , 1984, The American journal of cardiology.

[14]  I Schnittger,et al.  Reproducibility of left ventricular volumes by two-dimensional echocardiography. , 1983, Journal of the American College of Cardiology.

[15]  R. Kerber,et al.  In vitro analysis of boundary identification techniques used in quantification of two-dimensional echocardiograms. , 1984, The American journal of cardiology.