Structural Health Monitoring System Developed for Dalian Stadium

The peripheral structure of Dalian stadium is a long-span spatial truss structure. To ensure the safety of the peripheral structure during construction and operation period, the permanent structure health monitoring system is implemented. This paper first introduces the structural features of the Dalian stadium, and then illustrates the permanent monitoring program from the aspects of the hardware, the monitoring scheme and the function. This developed monitoring system is utilized to monitor the stress of the truss, and the dynamic response of the structure. Large amounts of data are obtained through the health monitoring system, and thus the safe condition of the structure can be evaluated based on data analysis.

[1]  Ting-Hua Yi,et al.  Recent research and applications of GPS‐based monitoring technology for high‐rise structures , 2013 .

[2]  Li Hongnan,et al.  ADVANCES IN STRUCTURAL HEALTH MONITORING SYSTEMS IN CIVIL ENGINEERING , 2008 .

[3]  Cheng-Wu Chen,et al.  RETRACTED: Identification and monitoring of bridge health from ambient vibration data , 2011 .

[4]  Heung-Fai Lam,et al.  Analysis and design of the general and outmost-ring stiffened suspen-dome structures , 2003 .

[5]  Zhou Xue-jun STRUCTURAL DESIGN AND HEALTH MONITORING OF JINAN OLYMPIC SPORTS CENTER , 2010 .

[6]  Marcello Vanali,et al.  The measurement network of the san siro meazza stadium in milan: origin and implementation of a new data acquisition strategy for structural health monitoring , 2010 .

[7]  Claus-Peter Fritzen,et al.  A note on fast computation of effective independence through QR downdating for sensor placement , 2009 .

[8]  Michael A. Davis,et al.  Fiber grating sensors , 1997 .

[9]  Zhang Ailin Study on prestress construction monitoring of the badminton gymnasium for 2008 Olympic Games , 2007 .

[10]  Jie Qiao,et al.  Application of fetoscopy in the management of monochorionic multiple pregnancies , 2010 .

[11]  Ting-Hua Yi,et al.  Experimental assessment of high-rate GPS receivers for deformation monitoring of bridge , 2013 .

[12]  Antonio R. Marí,et al.  NONLINEAR TIME-DEPENDENT ANALYSIS OF SEGMENTALLY CONSTRUCTED STRUCTURES , 1998 .

[13]  Ting-Hua Yi,et al.  Characterization and extraction of global positioning system multipath signals using an improved particle-filtering algorithm , 2011 .

[14]  Ting-Hua Yi,et al.  Reviews on innovations and applications in structural health monitoring for infrastructures , 2014 .

[15]  Yl L. Xu,et al.  VIBRATION STUDIES OF TSING MA SUSPENSION BRIDGE , 1997 .

[16]  A. M. R. Ribeiro,et al.  A review of vibration-based structural health monitoring with special emphasis on composite materials , 2006 .

[17]  Tommy H.T. Chan,et al.  Fiber Bragg grating sensors for structural health monitoring of Tsing Ma bridge : Background and experimental observation , 2006 .